AcuityBrand EVO/ICO Cylinder Wall Mount Fixtures User Manual
- June 10, 2024
- AcuityBrand
Table of Contents
Acuity Brand EVO/ICO Cylinder Wall Mount Fixtures
Product Information
The Gotham Architectural Downlighting is a lighting fixture designed for indoor use. It is intended to provide general illumination in commercial and residential spaces. The fixture is available in different models, with various sizes, shapes, and fixture types. It comes with different mounting options for easy installation and maintenance.
The fixture operates on a specified voltage, which should be verified before installation. It is designed to work with compatible drivers, and the maximum wattage should not be exceeded. The fixture is equipped with LED light sources that require cooling to prevent overheating and damage. It comes with warning labels for safety and usage instructions to ensure optimal performance.
Product Usage Instructions
Before installing, servicing, or performing maintenance on the fixture, disconnect or turn off the power to prevent electric shock. Wear gloves and safety glasses at all times during handling to avoid injury. Make sure to avoid direct eye exposure to the light source while it is on.
Verify that the supply voltage is correct by comparing it with the luminaire label information. All electrical and grounded connections should be made in accordance with the National Electrical Code (NEC) and any applicable local code requirements. Wiring connections should be capped with UL approved recognized wire connectors.
To prevent burn risks, allow the lamp/fixture to cool before handling. Do not touch the enclosure or light source, and do not exceed the maximum wattage marked on the luminaire label. Follow all manufacturer’s warnings, recommendations, and restrictions for driver type, burning position, mounting locations/methods, replacement, and recycling.
To prevent fire risks, keep combustible and other materials that can burn away from the lamp/lens. Do not operate in close proximity to persons, combustible materials, or substances affected by heat or drying. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling. Only use the fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before installation. Electrostatic Discharge (ESD) can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit. Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance. Some components inside the fixture may not be serviceable. In case of service requirement, contact an ABL representative for assistance. Always read the fixture’s complete installation instructions prior to installation for any additional fixture-specific instructions.
Regular maintenance programs are recommended to ensure optimal performance and safety. In case of any further information or particular problems that are not covered sufficiently in the user manual, refer to Acuity Brands Lighting, Inc.
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
- Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
- Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
INSTALLATION INSTRUCTIONS
These installation instructions are used for installing the follow ing luminaires and kits.
**Identification of Wall Mount Luminaires
**
**Identification of mounting variations
**
Fixture Install (JBX)
NOTE:
- Wall Mount JBX type fixtures are designed to be mounted to a 1.5” minimum depth, 4” square or octagonal junction box.
- Fixtures with DMX (EDXB) drivers require a 2.125” minimum depth, 4” octagonal junction box.
-
Remove the mounting plate from the fixture by using a 5/64” Allen w rench to loosen the tw o set screw s on the bottom of the canopy.
-
Take the mounting plate and pull the supply w ires through the center hole. Secure the mounting plate to the w all using the junction box screw s. Use a level to ensure the mounting plate is level before securing the screw s. Do not pinch supply wires between the mounting plate and w all.
-
Attach the safety cable on the fixture to the mounting plate as show n below . Let fixture hang w hile making supply w ire connections.
-
While fixture is hanging, make supply connections per diagram below . Push the connections back through the center hole in the mounting plate into the junction box.
-
Hook the top of the fixture w all canopy w ith the mounting plate and rotate until the fixture is hanging vertical on the w all.
-
Secure the fixture on the w all by tightening the tw o set screw s on the bottom side of the w all canopy using a 5/64” Allen w rench.
-
Once the fixture is installed, inspect the reflector for dirt, fingerprints, etc. If necessary, clean he reflector w ith a non-abrasive cleaner. It is recommended that the reflector be cleaned periodically to retain optimum photometric performance.
NOTE: A cosmetic bead of caulk may be necessary in betw een the canopy and w all for inconsistent w all surfaces. -
For tilt rotate fixtures, go to Section E.
Fixture Install (JBXCC)
NOTE:
- Wall Mount JBXCC type fixtures are designed to be mounted to a 1.5” deep, 4” octagonal junction box.
-
Locate the conduit keys in the box for assembly into the fixture.
Conduit Keys (Conduit Canopies Only)- Blank Conduit Key (4) with 5/64” Allen wrench
- Conduit Key (4) with 5/64” Allen wrench
-
Select the appropriate keys and insert them into the correct conduit cover slots for each specific conduit configuration. Adjust set screw s in the keys to allow the keys to slide in completely.
Note: Keys accept ½” and ¾” EMT conduit ONLY. Conduit fittings may vary by manufacturer. If using ¾” set screw type fittings, the fitting may need to be rotated so that the set screw is off vertical for proper clearance with canopies. -
Remove the mounting plate from the fixture by using a 5/64” Allen w rench to loosen the four set screw s on the top and bottom of the conduit cover.
-
Take the mounting plate and pull the supply w ires through the center hole. Secure the mounting plate to the J- box using the junction box screw s. Use a level to ensure the Mounting Plate is level before securing the screw s. Do not pinch supply w ires betw een the mounting plate and junction box.
-
Attach the safety cable on the fixture to the mounting plate as show n below . Let fixture hang w hile making w ire connections.
-
While fixture is hanging, make supply connections per diagram below . Push the connections back through the center hole in the mounting plate into the junction box.
-
Make sure the four set screw s on the top and bottom sides of the conduit cover are not protruding on the inside of the cover. Align conduit cover over the J-box.
-
Secure the fixture on the w all by tightening the four set screw s on the top and bottom sides of the conduit cover using a 5/64” Allen w rench.
-
Once the fixture is installed, inspect the reflector for dirt, fingerprints, etc. If necessary, clean he reflector w ith a non-abrasive cleaner. It is recommended that the reflector be cleaned periodically to retain optimum photometric performance.
NOTE: A cosmetic bead of caulk may be necessary in betw een the canopy and w all for inconsistent w all surfaces. -
For tilt rotate fixtures, go to Section E.
Tilt Adjustment
NOTE: For tilt-rotate fixtures, there are tilt and rotate features that allow for specific positioning. The tilt feature provides +40 degrees and -20 degrees of adjustment from the vertical position. The rotate feature provides +/- 40 degrees of adjustment from the vertical position.
- Loosen the set screw and the socket head cap screw using a 5/64” and 3/16” Allen w rench.
- Tilt the fixture to the desired angle.
- Once in the desired position, hand tighten the socket head cap screw . Then hand tighten the set screw to lock it in place.
IMPORTANT: DO NOT ATTEMPT TO ROTATE WHILE SET SCREW IS TIGHTENED DOWN. THIS CAN CAUSE DAMAGE TO THE LOCKING PERFORMANCE.
Rotate Adjustment
- Loosen the set screw using a 5/64” Allen w rench.
- Rotate the fixture to the desired angle.
- Hand tighten the set screw to lock it in place.
IMPORTANT: DO NOT ATTEMPT TO ROTATE WHILE SET SCREW IS TIGHTENED DOWN. THIS CAN CAUSE DAMAGE TO THE LOCKING PERFORMANCE.
GOTHAM ARCHITECTURAL DOWNLIGHTING
P: 1-800-705-SERV (7378)
www.gothamlighting.com
© Acuity Brands Lighting, Inc. 2019
CJ53522 Rev . D
All Rights Reserved.
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
- Home | Gotham Lighting
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>