perfect aire 3PAMSH36B-SZW Remote Control Owner’s Manual
- June 10, 2024
- Perfect Aire
Table of Contents
3PAMSH36B-SZW Remote Control
Owner’s Manual MODELS: 3PAMSH30B-SZW, 3PAMSH36B-SZW
IMPORTANT NOTE:
Read the manual carefully. Make sure to save this manual for future reference.
Illustrations in this manual are for explanatory purposes only, your actual
product may look slightly different.
REMOTE CONTROL
The remote control transmits signals to the system.
**** | Cooling indicator | AI SMART indicator | |
---|---|---|---|
Dry indicator | Super indicator | ||
Fan only indicator | iFeel indicator | ||
8°C Heating indicator | Display temperature | ||
Heating indicator | Signal transmit | ||
Sleep 1 indicator | Lock | ||
Sleep 2 indicator | Wisdom eye indicator | ||
Sleep 3 indicator | Airflow Follow You indicator | ||
Sleep 4 indicator | Airflow Avoid You indicator | ||
Auto fan speed | Airflow left & right indicator | ||
Higher fan speed | Airflow up & down indicator | ||
High fan speed | Indoor clean indicator | ||
Medium fan speed | Outdoor clean indicator | ||
Low fan speed | Fresh indicator | ||
Lower fan speed | HI-NANO indicator | ||
Quiet indicator | Display set timer | ||
Economy indicator | Display current time |
NOTE: Each mode and relevant function will be further specified in following pages.
HOW TO INSERT THE BATTERIES
- Remove the battery cover according to the arrow direction.
- Insert new batteries making sure that the (+) and (-) of battery are matched correctly.
- Reattach the cover by sliding it back into position.
NOTE: Use 2 LR03 AAA (1.5 volt) batteries. Do not use rechargeable
batteries. Replace batteries with new ones of the same type when the display
becomes dim.
STORAGE AND TIPS FOR USING THE REMOTE CONTROL
The remote control may be stored mounted on a wall with a holder.
TIPS & REGULATIONS FOR USING REMOTE CONTROL
To operate the room air conditioner, aim the remote control to the signal
receptor. The remote control will operate the air conditioner at a distance of
up to 21ft/7m when pointing at signal receptor of indoor unit.
CAUTION
For appropriate signal transmission between remote control and indoor unit,
keep the signal receiver away from the following items:
- Direct sunlight or other strong lights or heat
- Flat panel television screen or other electrical appliances that react to the remote control
Additionally, the air conditioner will not operate if curtains, doors or other materials block the signals from the remote control to the indoor unit. If the signal may not be transmitted properly, either move these materials or consult your local dealer.
OPERATION INSTRUCTIONS
OPERATION MODES
TURNING ON
Press button.
Result: The RUN indicator of the indoor unit lights up.
- Changing modes during operation, sometimes the unit does not respond at once. Wait 3 minutes.
- During heating operation, airflow is not discharged at the beginning. After 2-5 minutes, the airflow will be discharged until temperature of indoor heat exchanger rises.
- Wait 3 minutes before restarting the appliance.
SETTING TEMPERATURE
Press “ + ” button once
Result: Raise temperature setting by 1°F/1°C
Press “ – ” button once
Result: Raise temperature setting by 1°F/1°C
RANGE OF AVAILABLE SET TEMPERATURE
HEATING, COOLING | 61°F-86°F/16°C~30°C |
---|---|
DRY | -7 ~ 7 |
FAN ONLY | unable to set |
NOTE: Dry Mode can be increased or decreased 7° (in 1°F/1°C intervals) to
keep the room at a comfortable temperature.
SELECTING MODE
Press button one by one
Result: The operation modes changed in sequence:
FAN MODE
Press button one by one
Result: The fan speed is changed in sequence:
When in “Fan Only” mode, the “Auto” mode is not available.
When in “Dry Mode”, the fan speed is automatically set to “Auto”. “Fan
Speed” is ineffective in this case.
SWING, SMART, CLOCK, SUPER, TIMER, QUIET, LOCK, ECONOMY, iFEEL, DIMMER , 8°C
HEAT, and SLEEP operation modes will be specified on the following pages.
AIRFLOW DIRECTION CONTROL
Vertical airflow (horizontal airflow) is automatically adjusted to a certain
angle in accordance with the operation mode after turning on the unit.
OPERATION MODE | DIRECTION OF AIRFLOW |
---|---|
Cooling, Dry | Horizontal |
Heating, Fan Only | Downward |
The direction of airflow can be also adjusted to your own requirement by
pressing the “ “ buttons of the remote control.
VERTICAL AIRFLOW CONTROL
(WITH THE REMOTE CONTROL)
Use the remote control to set various or specific angles of flow.
Press button once.
Result: The vertical adjustment louvre will swing up and down
automatically. Press button again.
Result: The louvers swing to a suitable angle as desired.
HORIZONTAL AIRFLOW CONTROL
(WITH THE REMOTE CONTROL)
Use the remote control to set various or specific angles of flow.
Press button once.
Result: The horizontal adjustment louver will swing left and right
automatically.
Press button again.
Result: The louvers swing to a suitable angle as desired.
A. Do not turn the vertical adjustment louvers manually, otherwise
malfunction may occur. If that happens, turn off the unit first and cut off
the power supply. Wait three minutes to allow compressor to fully stop, then
restore power supply.
B. To prevent condensed water from dripping from indoor unit, do not use
downward tilted louver position for long periods of time.
AI SMART MODE
HOW TO SET AI SMART MODE
Press the button.
Result: Enters AI SMART mode
When in AI SMART mode, you can press the “+” and “-” button to change the
temperature setting (setting range is -7ºC to 7ºF).
NOTE: “SUPER” mode and “ECONOMY” mode are not available.
HOW TO CANCEL THE AI SMART MODE
Press the button.
Result: The AI SMART mode will be canceled.
QUIET MODE
In this mode, system will run the fan and compressor on a lower frequency for
a quieter performance.
Press button once to start QUIET mode.
Result: The Quiet indicator appears on the display
NOTE: Press QUIET MODE, FAN SPEED, SMART, SUPER or ON/OFF button to
cancel QUIET mode.
CLOCK BUTTON
HOW TO ADJUST THE REAL TIME
-
Press the CLOCK button for about 5 seconds.
Result: The time flashes on the LCD. -
Press “+” and “-” buttons.
Result: Press for 1 second to increase or decrease the timer in 1 minute intervals.
Hold for 1.5 seconds to increase or decrease the timer in 10 minute intervals.
Hold for about 2 seconds to increase or decrease the timer in 1 hour intervals. -
Press the CLOCK button once again.
Result: The real time is set.
LOCK MODE
Press button for about 5 seconds to start LOCK mode. The lock indicator
appears on the display.
Press button for about 5 seconds once again to stop LOCK mode. The lock
indicator disappears.
SUPER MODE
SUPER mode is used to start or stop fast cooling or heating, but only when the
unit is on.
SUPER mode can be set when the appliance is in operation or energized.
In SUPER mode, you can set temperature, airflow direction or timer.
HOW TO SET SUPER MODE
Press button at the cool, dry and fan only mode.
Result: At high fan speed, the set temperature automatically to
61°F/16°C.
Press button in Heat mode.
Result: In Auto Fan speed, the temperature is automatically set to
86°F/30°C.
HOW TO CANCEL SUPER MODE
Press SUPER MODE, FAN SPEED, ON/OFF or SLEEP button.
Result: The display will return to the original mode. Escape from SUPER
mode.
NOTE: SMART button is not available in SUPER mode. ECONOMY button is
ineffective in SUPER mode. The Appliance will continue working in SUPER mode
for 15 minutes , if you don’t escape from it by pressing any of the buttons
mentioned above.
TIMER MODE
The TIMER MODE can be set to turn the system ON at a set time, then turn OFF
at a set time within the same 24 hour interval.
TIMER ON and TIMER OFF functions can also be used independently.
HOW TO SET TIMER ON
-
Press button.
Result: “12:00 ON” flashes on the LCD. -
Press “+” and “-” buttons.
Result: Press for 1 second to increase or decrease the timer in 1 minute intervals.
Hold for 1.5 seconds to increase or decrease the timer in 10 minute intervals.
Hold for about 2 seconds to increase or decrease the timer in 1 hour intervals. -
When your desired time is displayed on LCD, press the ON TIMER button and confirm it.
Result: “ON” stops flashing – the TIMER indicator on the indoor unit lights up (invalid for multi system). -
After the set timer displayed for 5 seconds the clock will be displayed on the LCD of the remote control instead of set timer.
HOW TO SET TIMER OFF
-
Press button.
Result: “12:00 OFF” flashes on the LCD. -
Press “+” and “-” buttons.
Result: Press for 1 second to increase or decrease the timer in 1 minute intervals.
Hold for 1.5 seconds to increase or decrease the timer in 10 minute intervals.
Hold for about 2 seconds to increase or decrease the timer in 1 hour intervals. -
When your desired time is displayed on LCD, press the OFF TIMER button and confirm it.
Result: “OFF” stops flashing – the TIMER indicator on the indoor unit lights up (invalid for multi system). -
After the set timer displayed for 5 seconds the clock will be displayed on the LCD of the remote control instead of set timer.
HOW TO CANCEL TIMER ON
Press button.
Result: “ON” indicator disappears – the time on mode has been canceled.
NOTE: It is similar to set TIMER OFF, you can make the appliance switch off automatically at your desired time.
iFEEL MODE
iFEEL mode can read the current room ambient temperature by using a sensor
built into the remote control. The system will automatically adjust to keep
all areas of the room at the same temperature.
NOTE: iFEEL mode function works best if the remote control is placed on
the opposite side of the room as the indoor unit and out of direct airflow.
NOTE: Remote must still be within an unblocked 21ft/7m signal receiving
range to communicate with indoor unit.
HOW TO SET iFEEL MODE
Press the iFeel button once.
Result: The transmit signal in the display will appear, the iFeel
function will be started.
NOTE: The default setting is iFeel inactive.
HOW TO CANCEL iFEEL MODE
Press the iFeel button once.
Result: iFeel function will be shut off.
8°C HEAT MODE
HOW TO SET THE 8°C HEATING
Press the 8°C HEAT button at the heating mode.
In 8°C HEAT mode, the fan speed is set at “AUTO” automatically.
The 8°C HEAT mode will be started when you press 8°C HEAT button at the
heating mode.
If you press any button except for iFEEL, TIMER ON, TIMER OFF, CLOCK, SWING
and AIRFLOW FOLLOW/AVOID YOU buttons, you can escape from 8°C HEAT mode. Then
the display will disappear and the 8°C HEATING mode will be cancelled.
NOTE: In 8°C HEATING mode, the default temperature is set 46°F/8°C.
8°C HEATING mode can be set only when the air conditioner works in the heating
mode.
NOTE: 8°C HEATING mode can be used to help keep areas that do not need to
be fully heated above freezing temperatures.
DIMMER BUTTON
Press the button for about 5 seconds to turn off the light and the display in
the unit.
NOTE: When the display light is set to off, a received signal from remote
will turn the light back on.
ECO MODE
In this mode, air conditioner will run the fan and compressor on lowest
frequency to save energy.
Press ECO button for about 3 seconds to start ECO mode.
Result: The indicator appears on the display. Fan speed will be auto set to
low.
ECONOMY button is ineffective in SUPER and AI SMART mode.
Press ON/OFF MODE, TEMP +, TEMP -, FAN SPEED, SLEEP, QUIET or ECO button
to cancel ECO Mode.
**** Pressing ECO button for 1 second turns on HI-NANO indicator, this
feature is not available.
SLEEP MODE
SLEEP mode can be set in COOLING, HEATING or DRYING mode.
This function gives you a more comfortable environment for sleep.
- The appliance will automatically stop after it has been operating for 8 hours.
- Fan speed is automatically set at low speed.
HOW TO SET SLEEP MODE
Each time button is pressed.
Result: The operation mode is changed in sequence:
SLEEP MODE 1:
Cool Mode: Set temperature will increase 2°F/2°C within the first 2
hours. Temperature will then stay steady until Sleep Mode is finished.
Heat Mode: Set temperature will decrease 2°F/2°C within the first 2
hours. Temperature will then stay steady until Sleep Mode is finished.
SLEEP MODE 2:
Cool Mode: Set temperature will increase 2°F/2°C within the first 2
hours, increase 1°F/1°C after 6 hours, decrease by 1°F/1°C after 7 hours.
Temperature will then stay steady until Sleep Mode is finished.
Heat mode: Set temperature will decrease 2°F/2°C after 2 hours, increase
1°F/1°C after 6 hours, increase 1°F/1°C after 7 hours. Temperature will then
stay steady until Sleep Mode is finished.
SLEEP MODE 3:
Cool Mode: Set temperature will increase 1°F/1°C after 1 hour, increase
by 2°F/2°C after 2 hours, decrease 2°F/2°C after 6 hours, decrease 1°F/1°C
after 7 hours. Temperature will then stay steady until Sleep Mode is finished.
Heat mode: Set temperature will decrease 2°F/2°C after 1 hour, decrease
by 2°F/2°C after 2 hours, increase 2°F/2°C after 6 hours, increase 1°F/1°C
after 7 hours. Temperature will then stay steady until Sleep Mode is finished.
SLEEP MODE 4:
Set temperature will stay steady.
NOTE: Press SUPER, SMART MODE, ON/OFF or FAN SPEED button cancel SLEEP
mode.
By pressing “Sleep button” four times, or selecting other modes like SUPER,
SMART, or FAN SPEED, you could cancel the sleeping function of those units.
5401 Dansher Road
Countryside, IL 60525
844-4PA-AIRE | 844-472-2473 |
support@perfectaire.us
CANADA SUPPORT 877-997-2473 |
supportcanada@perfectaire.us
www.perfectaire.us
Printed in China | 1021_M873
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>