perfect aire 3PAMSH09A-SZW Single-Zone Mini-Split Remote Control Owner’s Manual

June 8, 2024
Perfect Aire

OWNER’S MANUAL
REMOTE CONTROL
SINGLE-ZONE MINI-SPLIT
MODELS: 3PAMSH09A-SZW, 3PAMSH09B-SZW, 3PAMSH12A-SZW,
3PAMSH12B-SZW, 3PAMSH18B-SZW, 3PAMSH24B-SZW

3PAMSH09A-SZW Single-Zone Mini-Split Remote Control

SPECIFICATIONS:

Remote Model RG10A4(D1)/BGEFU1
Indoor Unit Models  3PAMSH09A-SZW, 3PAMSH09B-SZW, 3PAMSH12A-SZW, 3PAMSH12B-

SZW, 3PAMSH18B-SZW, 3PAMSH24B-SZW
Rated Voltage| 3.0V (Dry batteries R03/LR03×2)
Signal Receiving Range| 24 ft. / 8 m
Environment| 23°F~140°F(-5°C~60°C)

IMPORTANT NOTE:
Read the manual carefully. Make sure to save this manual for future reference. Illustrations in this manual are for explanatory purposes only, your actual product may look slightly different.

WARNING: Cancer www.P65Warnings.ca.gov

QUICK START GUIDE

perfect aire 3PAMSH09A-SZW Single-Zone Mini-Split Remote Control - QUICK
START GUIDE

NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.

SPECIAL NOTE:

  • Button designs on your unit may differ slightly from the example shown.
  • If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
  • When there are wide differences between “Remote control Manual” and “USER’S MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.

HANDLING THE REMOTE CONTROL

INSERTING AND REPLACING BATTERIES
Your air conditioning unit may come with two AAA batteries. Put the batteries in the remote control before use.

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

BATTERY NOTES For optimum product performance:

  • Do not mix old and new batteries, or batteries of different types.
  • Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.
    Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.

TIPS & REGULATIONS FOR USING REMOTE CONTROL

TIPS

  • The remote control must be used within 24 Feet / 8 Meters of the unit.
  • The unit will beep when remote signal is received.
  • Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
  • Remove batteries if the remote will not be used more than 2 months.

REGULATIONS
The device could comply with the local national regulations.

  • In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
  • In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
    (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.

BUTTONS AND FUNCTIONS

perfect aire 3PAMSH09A-SZW Single-Zone Mini-Split Remote Control - BUTTONS
AND FUNCTIONS

Model: RG10A4(D1)/BGEFU1
NOTE: Press together ∧ & ∨ buttons at the same time for 3 seconds will alternate the temperature display between the °F & °C scale. Fresh feature is not available. AP Feature not available.

REMOTE SCREEN INDICATORS

perfect aire 3PAMSH09A-SZW Single-Zone Mini-Split Remote Control -
TRANSMISSION

NOTE: All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation, only the relative function signs are shown on the display window.

HOW TO USE BASIC FUNCTIONS

ATTENTION:
Before operation, please ensure the unit is connected to a main source of electricity and power is available.

SETTING TEMPERATURE
The operating temperature range for units is 62-86°F (17-30°C/20-28°C).
You can increase or decrease the set temperature in 1°F (1°C) increments.

AUTO MODE
In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT operation based on the set temperature.

  1. Press the MODE button to select AUTO.
  2. Set your desired temperature using the TEMP ∧ or TEMP ∨ button.
  3. Press the ON/OFF button to start the unit.

NOTE: FAN SPEED can’t be set in AUTO mode.

HEAT MODE

  1. Press the MODE button to select HEAT mode.
  2. Set your desired temperature using the TEMP ∧ or TEMP ∨ button.
  3. Press FAN button to select the fan speed:
  4. AUTO, LOW, MED or HIGH
  5. Press the ON/OFF button to start the unit.

NOTE: As outdoor temperature drops, the performance of your unit’s HEAT function may be affected. In such instances, we recommend using this air conditioner in conjunction with other heating appliances.

DRY MODE (DEHUMIDIFYING)

  1. Press the MODE button to select DRY mode.
  2. Set your desired temperature using the TEMP ∧ or TEMP ∨ button.
  3. Press the ON/OFF button to start the unit.

NOTE: FAN SPEED can’t be changed in DRY mode.

COOL MODE

  1. Press the MODE button to select COOL mode.
  2. Set your desired temperature using the TEMP ∧ or TEMP ∨ button.
  3. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH
  4. Press the ON/OFF button to start the unit.

FAN MODE

  1. Press the MODE button to select FAN mode.
  2. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
  3. Press the ON/OFF button to start the unit.

NOTE: You can’t set temperature in FAN mode. As a result, your remote control’s LCD screen will not display temperature.

SETTING THE TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.

TIMER ON SETTING
Press TIMER button to initiate the ON time sequence.
Press Temp. up or down button for multiple times to set the desired time to turn on the unit.
Point remote to unit and wait 1sec, the TIMER ON will be activated.

TIMER OFF SETTING
Press TIMER button to initiate the OFF time sequence.
Press Temp. up or down button for multiple times to set the desired time to turn on the unit.
Point remote to unit and wait 1sec, the TIMER OFF will be activated.

perfect aire 3PAMSH09A-SZW Single-Zone Mini-Split Remote Control - TIMER OFF
SETTING

TIMER ON & OFF SETTING (example)
Keep in mind that the time periods you set for both functions refer to hours after the current time.

Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.perfect aire
3PAMSH09A-SZW Single-Zone Mini-Split Remote Control - current
timer

NOTE:

  1. When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
  2. Cancel either function by setting its timer to 0.0h.

HOW TO USE ADVANCED FUNCTIONS

LED DISPLAY

PRESS LED BUTTON to turn on and turn off the display on the indoor unit.| KEEP PRESSING THIS BUTTON MORE THAN 5 SECONDS, the indoor unit will display the actual room temperature. Press more than 5 seconds again will revert back to display the setting temperature.
---|---
|

SWING

perfect aire 3PAMSH09A-SZW Single-Zone Mini-Split Remote Control -
SWING

The horizontal louver will swing up and down automatically when PRESSING SWING BUTTON.
Press again to make it stop.perfect aire 3PAMSH09A-SZW Single-Zone Mini-
Split Remote Control - make it stop

KEEP PRESSING THIS BUTTON MORE THAN 2 SECONDS, the vertical louver swing function is activated.

TURBO

When you SELECT TURBO FEATURE IN COOL MODE, the unit will blow cool air with strongest wind setting to jump-start the cooling process.
When you select TURBO FEATURE IN HEAT mode, for units with Electric heat elements, the Electric HEATER will activate and jump-start the heating process.

SHORTCUT

PRESS SHORTCUT BUTTON when remote control is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature (if activated).
IF PUSHING MORE THAN 2 SECONDS, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature (if activated ).

SLEEP ( ):

THE SLEEP FUNCTION is used to decrease energy use while you sleep (and don t need the same temperature settings to stay comfortable).
This function can only be activated via remote control. For the detail, see “sleep operation” in “USER’S MANUAL”.
NOTE: The SLEEP function is not available in FAN or DRY mode.

FP
The unit will operate at high fan speed (while compressor on) with temperature automatically set to 46°F/ 8°C.

Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel this function.

SILENCE

KEEP PRESSING FAN BUTTON FOR MORE THAN 2 SECONDS to activate/disable Silence function.
Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity.
Press ON/OFF, Mode, Sleep, Turbo or Clean button while operating will cancel silence function.

SET

PRESS THE SET BUTTON to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm.
To cancel the selected function, just perform the same procedures as above.
Press the SET button to scroll through operation functions as follows:
Fresh( ) → Sleep( ) → Follow Me( ) → AP mode( )

CLEAN

Airborne bacteria can grow in the moisture that condenses around heat exchanger in the unit. With regular use, most of this moisture is evaporated from the unit. By PRESSING THE CLEAN BUTTON, your unit will clean itself automatically. After cleaning, the unit will turn off automatically. Pressing the CLEAN button mid-cycle will cancel the operation and turn off the unit. You can use CLEAN as often as you like.

NOTE: You can only activate this function in COOL or DRY mode.

FOLLOW ME ( ):
The FOLLOW ME FUNCTION enables the remote control to measure the temperature at its current location and send this signal to the air conditioner every 3 minutes interval.
NOTE: Remote be within a 24 ft./8 m unblocked signal receiving range to communicate with indoor head.
When using AUTO, COOL or HEAT modes, measuring ambient temperature from the remote control (instead of from the indoor unit itself) will enable the air conditioner to optimize the temperature around you and ensure maximum comfort.

NOTE: Press and hold Turbo button for seven seconds to start/stop memory feature of Follow Me function.

  • If the memory feature is activated, “ON” displays for 3 seconds on the screen.
  • If the memory feature is stopped, “OFF” displays for 3 seconds on the screen.
  • While the memory feature is activated, press the ON/OFF button, shift the mode or power failure will not cancel the Follow me function.

LOCK

PRESS TOGETHER CLEAN AND TURBO BUTTON
at the same time more than 5 seconds to activate Lock function. All buttons will not response except pressing these two buttons for two seconds again to disable locking.

5401 Dansher Road
Countryside, IL 60525
844-4PA-AIRE | 844-472-2473 | support@perfectaire.us
CANADA SUPPORT 877-997-2473 | supportcanada@perfectaire.us
www.perfectaire.us
Printed in China | 0921_M857

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Perfect Aire User Manuals

Related Manuals