Dilution Solutions D14MZ2 IPK-14GPM Industrial Plumbing Kit Instruction Manual

June 10, 2024
Dilution Solutions

D14MZ2 IPK-14GPM Industrial Plumbing Kit

Product Information

The IPK34 – 14 GPM Industrial Plumbing Kit is designed for use with Dosatron units D14MZ2, D14MZ5, D14MZ10, and D14MZ3000. It includes various polypropylene and stainless steel valves, filters, regulators, and fittings for assembling the plumbing system. The kit also comes with an instruction card for easy setup and installation.

Product Usage Instructions

Quick Priming

  1. Shut off outlet ball valve
  2. Insert injection hose into the chemical container
  3. Turn on the stainless steel ball valve (collect discharged solution or send it to drain)
  4. Observe the injection hose. When full, count 10 clicks
  5. Shut off stainless steel ball valve
  6. Turn outlet ball valve on

Sample Collection

  1. Make sure the unit is primed
  2. Shut off outlet ball valve
  3. Turn stainless steel ball valve on
  4. In a clean container, collect 2.5 gallons of diluted solution
  5. Shut off stainless steel ball valve
  6. Collect sample out of the 2.5 gallons and check concentration
  7. Turn on the outlet valve

Assembly Instructions

  1. Wrap all male fittings with 5 – 6 turns of Teflon tape if white, only 3 – 4 turns if pink or blue tape.
  2. Install the following parts with their arrows pointing in the direction of the flow: Check valve, Filter, Pressure regulator
  3. Attach the instruction card to the injector.

Note: When connecting a Dosatron either to the public water supply or to its own water source, you must respect the regulations in force concerning protection of the source i.e. backflow prevention, etc. Parts ordered, or pictured, may look slightly different than the image displayed, but the fit and function will be the same.

ASSEMBLY

For quick priming (helpful at low water flows):

  • Shut off outlet ball valve
  • Insert injection hose into the chemical container
  • Turn on the stainless steel ball valve (collect discharged solution or send it to drain)
  • Observe the injection hose. When full, count 10 clicks Shut off stainless steel ball valve
  • Turn outlet ball valve on

For sample collection

  • Make sure the unit is primed
  • Shut off outlet ball valve
  • Turn stainless steel ball valve on
  • In a clean container, collect 2.5 gallons of diluted solution Shut off stainless steel ball valve
  • Collect sample out of the 2.5 gallons and check concentration Turn on the outlet valve

INSTRUCTIONS

  1. Wrap all male fittings with 5 – 6 turns of Teflon tape if white, only 3 – 4 turns if pink or blue tape.
  2. Install the following parts with their arrows pointing in the direction of the flow:
    • Check valve
    • Filter
    • Pressure regulator
  3. Attach the instruction card to the injector.

What Includes

Qty IPK34 – 14 GPM Includes: #
2 3/4” polypropylene single union ball valve 1
1 1/2” stainless steel ball valve 2
1 3/4” polypropylene 200 mesh tee filter 3
1 3/4” pressure regulator w/gauge 4
1 1” flow restrictor 14 GPM 5
2 1” to 3/4” reducer bushings 5
1 3/4” polypropylene check valve 6
2 3/4” union schedule 80 PVC 7
7 3/4” x 2” polypropylene fittings 8
1 1/2” x 2” polypropylene fitting 9
1 1/2” x 1/2” barb fitting 10
1 3/4” male to 1/2” female reducer bushing 11
1 3/4” Tee 12
3 3/4” street elbows 13
1 Roll of thread tape 14
1 Instruction card 15

warning: When connecting a DOSATRON either to the public water supply or to its own water source, you must respect the regulations in force concerning protection of the source i.e. backflow prevention, etc.

NOTE: Parts ordered, or pictured, may look slightly different than the image displayed, but the fit and function will be the same.

CUSTOMER SERVICE & TECHNICAL SUPPORT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals