GERMAN POOL DWM-060 Sterilizing Water Maker User Manual
- June 10, 2024
- GERMAN POOL
Table of Contents
DWM-060-M-21(1)
FOLD SIZE: 75 x 110mm
Sterilizing Water Maker
DWM-060
USER MANUAL
Please read these instructions and warranty information carefully before use and keep them handy for future reference.
Warnings and Safety Precautions
WARNING!
Read all instructions carefully before using this product.
- The sodium hypochlorite produced by this product is for external sterilization only. DO NOT drink the solution, and the product must be placed out of children’s reach at all times.
- During the generation process of the sodium hypochlorite, DO NOT operate the product for other uses to avoid damaging it.
- During the generation process of sodium hypochlorite, yellow filamentary sediments may appear in the solution, which is a natural occurrence. This is due to the abundance of iron ions in the water. Using salt with potassium ferrocyanide will also result in yellow filamentary sediments as well.
- The generated sterilizer should be used right away, otherwise the concentration may decrease due to factors like light and temperature. Shortening the time sterilizer staying in the container also helps to extend the service life of the product.
- Sodium hypochlorite sterilizer may corrode metals, please use with care.
- DO NOT apply sterilizer on non-white textiles made of natural fibre as it may cause a discoloring effect.
- DO NOT use the sodium hypochlorite sterilizer together with alcohol, vinegar, toilet cleaner or concentrated sulfuric acid.
- Sodium hypochlorite sterilizer can be used to clean humidifiers, but DO NOT place the sterilizer in the water tank for extended use.
- If the product will not to be used for a prolonged period, remove the nozzle, place the bottle upside down to let it dry completely before storage.
- When cleaning, use a dry cloth or slightly damp cloth to wipe the product surface. DO NOT use detergents or other sprays for cleaning.
- If too much refined salt has been added, stop using and rinse well with clean water.
- DO NOT place flammable materials close to the product.
- Use only refined salt and clean water, and DO NOT use water above 50°C, otherwise it may cause the product to malfunction.
- If the product or bottle is damaged, stop using it immediately to minimize the risk of explosion.
- DO NOT wash the external parts of the product with water, as the main body of the product is not waterproof.
- If strange noises, odour or smoke / gas is detected, unplug the product immediately and contact German Pool Customer Service and Repair Centre.
Product Structure
- Atomizer Nozzle
- Maximum Water Mark
- Power Supply Interface
- Touch Key
- Product Base
- Bottle
- Lid
Operating Instructions
WARNING!
DO NOT fill to above the maximum water mark.
1. Unscrew the atomizer nozzle, and fill bottle with 60ml tap water (DO NOT
fill to above the maximum water mark).
2. Add a suitable amount of refined salt into the water, shake the bottle for
approx. 30-60 seconds to let the refined salt to dissolve completely.
3. Connect the product to the power source. The product will enter standby
status, buzzer will beep once, indicator light will light up in blue for 2
seconds then go dark.
4. Press the Touch Key to cycle between Low Concentration Mode and High
Concentration Mode. Buzzer will beep once every time the key is pressed.
| Low Concentration Mode | High Concentration Mode
---|---|---
Indicator Light| Lights up constant in white| Lights up constant in blue
Solution components| 60 ml water 0.2 g refined salt| 60 ml water 0.2 g refined
salt
Preparation time| 4 minutes| 10 minutes
Sterilizer concentration| approx. 100 ppm| approx. 200 ppm
Usage| Sterilization, degrade pesticides | Sterilization, deodorization,
bleaching
Suitable for| Toothbrush, pet product, toy, air conditioner, shoe cabinet,
towel, bedding, fruit and vegetable, kitchen utensil| Bathroom, trash bin,
sewer, moldy area
5. After desired mode is selected, if there is no command input in 3 seconds, the product will automatically enter sterilizer-generating status. If user wishes to stop the sterilizer-generating process, simply unplug the power source.
WARNING!
When sterilizer is being generated, the atomizer nozzle MUST be removed,
and DO NOT touch the bottle to avoid spillage.
6. After sterilizer-generating process is completed, the indicator light will
flash, then buzzer will beep once and indicator light will turn off. Product
returns to standby status.
7. Screw on the atomizer nozzle, and press the nozzle to spray the
sterilizer.
Cleaning and Maintenance
WARNING!
Unplug the product from the power source before cleaning and maintenance. DO
NOT immerse the product in water or other liquids.
- Use dry or slightly damp cloth to wipe the surface of the product. DO NOT use cleaning agents or other sprays to clean the product.
- The base of the product is not waterproof. DO NOT use water to clean the exterior parts of the product.
- If product will not be used for an extended period of time, remove the atomizer nozzle, and turn the bottle upside down to air dry completely before storing it away.
- If the product or bottle is damaged, stop using the product immediately, and contact German Pool Customer Service and Repair Centre.
Technical Specification
Model | DWM-060 |
---|---|
Voltage | DC 5V |
Power | 5 W |
Net Weight | 120 g |
Specifications are subject to change without prior notice.
If there is any inconsistency or ambiguity between the English version and the
Chinese version, the Chinese version shall prevail.
Refer to www.germanpool.com for the most updated
version of the Operating Instructions.
Warranty Terms & Conditions
Under normal operations, the product will gurantee a 1-year full warranty provided by German Pool (effective from the date of purchase).
- This warranty is not valid until customer registration information is received by our Service Centre within 10 days of purchase via one of the following means:
- Visit our website and register online: www.germanpool.com/warranty
- Complete all the fields on the attached Warranty Card and mail it back to our Customer Service Centre.
Please fill out the form below. This information and the original purchase invoice will be required for any repairs. Warranty will be invalidated if information provided is found to be inaccurate.
Model No. : DWM-060
Serial No. : Invoice No. :
Purchased From : ___ Purchase Date : ____
-
Customer who fails to present original purchase invoice will not be eligible for free warranty service.
-
Customer should always follow the operating instructions. This warranty does not apply to:
– labour costs for on-site installation, check-up, repair, replacement of parts and other transportation costs;
– damages caused by accidents of any kind (including material transfer and others);
– operating failures resulting from applying incorrect voltage, improper usage, and unauthorized installations or repairs. -
This warranty is invalid if:
– the purchase invoice is modified by an unauthorized party;
– the product is used for any commercial or industrial purposes;
– the product is repaired or modified by unauthorized personnel, or unauthorized parts are installed;
– the serial number is modified, damaged or removed from the product. -
German Pool will, at its discretion, repair or replace any defective part.
-
This warranty will be void if there is any transfer of ownership from the original purchaser.
Customer Service & Repair Centre
Hong Kong
Unit B, G/F, Sunshine Kowloon Bay
Cargo Centre, 59 Tai Yip Street, Kowloon
Kowloon, Hong Kong
Tel : +852 2333 6249
Fax : +852 2356 9798
Email : repairs@germanpool.com
Macau
3/F, Edificio Industrial Pou Fung,
145 Rua de Francisco Xavier Pereira,
Macau
Tel : +853 2875 2699
Fax : +853 2875 2661
This warranty is valid only in Hong Kong and Macau
DWM-060-M-21(1)
Documents / Resources
|
GERMAN POOL DWM-060 Sterilizing Water
Maker
[pdf] User Manual
DWM-060 Sterilizing Water Maker, DWM-060, Sterilizing Water Maker, Water
Maker, Maker
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>