LOGICO2 Grow CO2 Enrichment Controller User Manual

June 9, 2024
logico2

LOGICO2-Grow-CO2-Enrichment-Controller-logo

LOGICO2 Grow CO2 Enrichment Controller

LOGICO2-Grow-CO2-Enrichment-Controller-product-image

Grow CO2 Enrichment Controller

The Grow CO2 Enrichment Controller is a device that measures the concentration of CO2 in the ambient environment of the room being controlled and opens/closes our enrichment valve to achieve a perfectly enriched CO2 environment in the grow room.

Technical specifications

  • Power supply: 24V DC

  • Mains power supply: Transient overvoltage’s up to the levels of overvoltage category II.
    NOTE: These levels of transient overvoltage are typical for equipment supplied from the building wiring.

  • Power consumption: 130 mA

  • Power consumption with Enrichment Valve (10 Watt): Max 550 mA

  • Measurement range: Altitude: 0-5000 ppm CO2 concentration Calibrated for altitude up to 5000 m.

  • Pollution degree: 2

  • Serial communication: Modbus protocol over RS485

  • Automatic calibration: At regular intervals

  • Operating humidity: 0-95% RH non condensed

  • LED indications:
    Red: Alarm – CO2 concentration over 5000 ppm,
    Green: Adding CO2 gas, Green: Power on

  • Installation: For indoor use

  • Dimensions (LxWxD): 90x161x38 mm (3.5×6.3×1.5)

  • Ingress protection: IP 56

Usage Instructions

Before installation, test the set to verify proper function by following these steps:

  1. Open the box and carefully take the components out of the package.

  2. Find the power supply in the package and attach the correct mains-adaptor for your country’s outlet, then connect the power supply to the electrical outlet. The set should now activate.

  3. Check that all LEDs on the Grow CO2 Enrichment Controller
    illuminate and that the built-in buzzers beep. This is part of the self- diagnostics program.

  4. Now your product is tested and you can start the installation.

Mount the Grow CO2 Enrichment Controller at the same height as the foliage of the plants, where the photosynthesis is taking place. If plant lighting is used in the greenhouse, make sure that the plant light hits the Grow CO2 Enrichment Controller. An internal light sensor in the Grow CO2 Enrichment Controller makes it possible to activate the CO2-control only when the plant lighting is on. It is possible to disable this function via DIP-switch.

The system control the CO2 level with a plug and play Enrichment Valve. If the CO2 gas for the grow room is produced by burning gas, use the RCB external relay box to start and stop the burner, instead of the Enrichment Valve. Both the Enrichment Valve and the RCB have RJ45 connectors for direct connection to the Grow CO2 Enrichment Controller.

Just like the LogiCO2 Safety CO2 Sensor, the Grow CO2 Enrichment Controller can be adjusted for the correct altitude.

WARNING! Please read the instruction manual carefully prior to start-up and use.
These instructions should be saved for future reference and passed on to any subsequent owner.
Failure to follow any of these instructions could result in bodily harm or death, and could void product warranties.
LogiCO2 International AB, its affiliates and third party providers assume no responsibility for claims arising from improper or careless use or handling of its products. Retain this instruction.

Grow CO2 Enrichment Controller for grow room and greenhouse.

WARNING!
Please read these instructions carefully prior to start-up and use. These instructions should be saved for future reference and passed on to any subsequent owner. Failure to follow any of these instructions could result in bodily harm or death, and could void product warranties. LogiCO2 International AB, its affiliates and third party providers assume no responsibility for claims arising from improper or careless use or handling of its products. Retain this instruction.

LEGAL NOTICE
All persons responsible for the operation and maintenance of this equipment must read and understand the safety and operating information contained in this guide. Installation and service of this equipment should be performed only by professionals. The function of the equipment will be impaired if it is not properly installed. Disconnection from supply source: When installing the Grow CO2 Enrichment Controller to the power net, please ensure that the fuse that the system runs on is clearly marked. This makes it easy to disconnect the power to the system, if needed. It is very important to be aware that the Grow CO2 Enrichment Controller does not function if disconnected from power mains.

Testing set, BEFORE INSTALLATION

The different sets are delivered pre-connected in the package.

Always test the set before installation to verify proper function!

  1. Open the box and carefully take the components out of the package.
  2. Find the power supply in the package and attach the correct mains-adaptor for your country’s outlet, then connect the power supply to the electrical outlet. The set should now activate.
  3. Check that all LEDs on the Grow CO2 Enrichment Controller illuminate and that the built-in buzzers beep. This is part of the self diagnostics program.
  4. Now your product is tested and you can start the installation.

Specifications

  • Power supply: 24V DC

  • Mains power supply: Transient overvoltage’s up to the levels of overvoltage category II.
    NOTE: These levels of transient overvoltage are typical for equipment supplied from the building wiring.

  • Power consumption: 130 mA

  • Power consumption with Enrichment Valve (10 Watt): Max 550 mA

  • Measurement range: 0-5000 ppm CO2- concentration

  • Altitude: Calibrated for altitude up to 5000 m.

  • Pollution degree: 2

  • Serial communication: Modbus protocol over RS485

  • Automatic calibration: At regular intervals

  • Operating temperature: Calibrated for operating between 32 – 115F (Sensor functions from -5F ) Calibrated for operating between 0 to 45°C (Sensor works from -20°C) but values valid only for 0-45°C).

  • Operating humidity: 0-95% RH non condensed

  • Storage temperature: -40 to + 70°C

LED indications

  • Red: Alarm – CO2 concentration over 5000 ppm
  • Green: Adding CO2 gas
  • Green: Power on
  • Installation: For indoor use
  • Dimensions (LxWxD): 90x161x38 mm 3.5”x6.3”x1.5”
  • Ingress protection: IP 56

Function

The LogiCO2 Grow CO2 Enrichment Controller is a device that measures the concentration of CO2 in the ambient environment of the room being controlled and opens/closes our enrichment valve to achieve a perfectly enriched CO2 environment in the grow room.
Mount the Grow CO2 Enrichment Controller at the same height as the foliage of the plants, where the photosynthesis is taking place. If plant lighting is used in the greenhouse, make sure that the plant light hits the Grow CO2 Enrichment Controller. An internal light sensor in the Grow CO2 Enrichment Controller makes it possible to activate the CO2-control only when the plant lighting is on. It is possible to disable this function via DIP-switch.

The system control the CO2 level with a “plug and play” Enrichment Valve. If the CO2 gas for the grow room is produced by burning gas, use the RCB external relay box to start and stop the burner, instead of the Enrichment Valve. Both the Enrichment Valve and the RCB have RJ45 connectors for direct connection to the Grow CO2 Enrichment Controller.
Just like the LogiCO2 Safety CO2 Sensor, the Grow CO2 Enrichment Controller can be adjusted for the correct altitude.

Adaptive CO2-control
The Grow CO2 Enrichment Controller is default set to use a fixed dosing time of 30 or 60 seconds every 5 minutes. The Grow CO2 Enrichment Controller also has an Adaptive CO2-control algorithm that automatically adjust the dosing time of CO2 between 10 to 120 seconds. This dosage of CO2 is done in intervals of 5 minutes. The initial dosage time is 30 seconds. It is possible to enable the Adaptive CO2-control via DIP-switch on the printed circuit board.

The Grow CO2 Enrichment Controller has an adjustable CO2 setpoint via a push button on the outside of the cover. The setpoint for the target CO2 concentration is adjustable from 700 to 2000 ppm in steps of 50 ppm. The default setpoint is 1200 ppm. Setpoint “OFF” stops the CO2 regulation.
The hysteresis can be set to 40 or 100 ppm and default setting is 40 ppm.

The display is alternately reading:

  • The current CO2 concentration
  • The CO2 target setpoint value
  • The current altitude setting (height over the ocean)

It can also show “Low” if the current concentration is 200 ppm below the setpoint, indicating for example that the CO2 container is empty. The green “Power on” LED starts blinking to indicate this function. If connected to a LogiCO2 Safety System Central Unit, the Central Unit will also show “/Low”, after the concentration value, on the display.

Optional Remote Connection box for fans
Use a RCB external relay box (0471) and connect it to the Grow CO2 Enrichment Controller, to activate greenhouse fans. The fans will be on when the Grow CO2 Enrichment Controller actively is controlling the CO2 concentration. If the light sensor in the Grow CO2 Enrichment Controller is enabled, the fans will be on if it is light and off when it is dark in the greenhouse. When it is dark, the Grow CO2 Enrichment Controller will also stop the CO2 enrichment.

Connected with CO2 Safety System
The Grow CO2 Enrichment Controller can be used in conjunction with the Mk9 CO2 Safety System to make the perfect combination of safety and efficiency.

When the Grow CO2 Enrichment Controller is connected to the Mk9 Central Unit the current CO2 concentration can also be read on the Central Unit’s display.

LED indications on the Grow CO2 Enrichment Controller

  • LOGICO2-Grow-CO2-Enrichment-Controller-01 Red: Alarm – CO2 concentration over 5000ppm.
  • Green: Adding CO2 gas
  • Green: Power on

If the display is showing “AbC0” at startup, the automatic CO2 calibration is disabled.
The LogiCO2 Safety System Central Unit display shows the ID number of the CO2 Sensor, its current CO2 concentration followed by:

  • Low: Concentration 200 ppm below the setpoint
  • On: CO2-control activated
  • Off: Only when light sensor is activated and it is dark

Explanations of symbols

  • LOGICO2-Grow-CO2-Enrichment-Controller-04 Direct current
  • LOGICO2-Grow-CO2-Enrichment-Controller-05 Double insulation

Accessories

  • Item code / Description
  • 0475 Enrichment valve with filter
  • 0471 RCB box, fan control

Installation

Mount the Grow CO2 Enrichment Controller at the same height as the foliage of the plants, where the photosynthesis is taking place. If plant lighting is used in the greenhouse, make sure the plant light hits the Grow CO2 Enrichment Controller. Avoid direct water spraying on the Grow CO2 Enrichment Controller.

The different units are connected to each other by cables. The blue marked cable is used for the Enrichment Valve and/or for the RCB external relay box, for activation of fans. The RCB external relay box can also be used to start and stop burner for production of CO2 gas.
The red marked cable are for communication and power. Please observe, all cables have splitters at the end to facilitate extended cable lengths. When installing, the cables may need to be disconnected for purposes of cable routing. When reconnecting, please make sure that you connect to the original splitters and connectors. If possible, route the cables through cable conduits between the units, for a neat and safe installation.

Protective collar seals and cable ties are included. They must be used as below to protect the RJ45 1-1 connector or RJ45 1-2 splitter from moisture and dust.

LOGICO2-Grow-CO2-Enrichment-Controller-06

Connecting to the power supply
A separate power supply (100-240 VAC) supplies power to the system. Please observe that you have to connect the appropriate plug adaptor to the power supply depending on which country you are in. Connect the power supply to the electrical outlet. Mount the included plug-lock so that the power supply can not be disconnected without the use of tools.
It is also possible to order a hardwired power supply option when and were it is needed.

LOGICO2-Grow-CO2-Enrichment-Controller-07

Display signs

Connection diagram

This connection diagram shows an example of how the different systems can be installed.

LOGICO2-Grow-CO2-Enrichment-Controller-09

LOGICO2-Grow-CO2-Enrichment-Controller-10

Grow CO2 Enrichment Controller, Internal layout

LOGICO2-Grow-CO2-Enrichment-Controller-11

Grow CO2 Enrichment Controller / Function/Indication

  1. DIP-switch 1 Setting of Grow CO2 Enrichment Controller functions
  2. DIP-switch 2 Service mode, ABC calibration and ID settings
  3. LED red Alarm – CO2 concentration over 5000ppm
  4. LED green Adding CO2 gas
  5. LED green Power ON
  6. Service button Service functions and altitude setting
  7. Buzzer Beeping: Alarm – CO2 concentration over 5000 ppm
  8. Temperature sensor Temperature can be shown on display
  9. Display CO2 measurement, Setpoint, altitude and other information
  10. RJ45 input connector Power and communication (red connector)
  11. RJ45 output connector Output to valve and fan activation
  12. Push button Toggle push button for choice of target CO2 setpoint
  13. Light sensor Internal light sensor for activation of CO2 control

Altitude adjustment height index table:

Height index Meter Feet
H-00 0 0
H-01 200 656
H-02 400 1312
H-03 600 1969
H-04 800 2625
H-05 1000 3281
H-06 1200 3937
H-07 1400 4593
H-08 1600 5249
H-09 1800 5906
H-10 2000 6562
H-11 2200 7218
H-12 2400 7874
Height index Meter Feet
--- --- ---
H-13 2600 8530
H-14 2800 9186
H-15 3000 9843
H-16 3200 10499
H-17 3400 11155
H-18 3600 11811
H-19 3800 12467
H-20 4000 13123
H-21 4200 13780
H-22 4400 14436
H-23 4600 15092
H-24 4800 15748
H-25 5000 16404

CO2 Sensor, Altitude adjustment

To change the altitude adjustment on the Grow CO2 Enrichment Controller please follow the simple instructions below.

  1. Press the push button, the display shows Alt.
    LOGICO2-Grow-CO2-Enrichment-Controller-12

  2. Current altitude setting is then shown.
    LOGICO2-Grow-CO2-Enrichment-Controller-13

  3. Press the button to adjust the altitude setting, in steps of 200 m (for feet, see the converter table). Observe! Adjust the altitude to the closest higher value for the location. To confirm setting, wait 10 seconds.
    LOGICO2-Grow-CO2-Enrichment-Controller-14

  4. The display returns to normal view after 10 seconds. Finished.
    LOGICO2-Grow-CO2-Enrichment-Controller-15

Altitude adjustment converter table

Meter Feet
0 0
200 656
400 1312
600 1968
800 2625
1000 3281
1200 3937
1400 4593
1600 5249
1800 5905
2000 6562
2200 7218
2400 7874
Meter Feet
--- ---
2600 8530
2800 9186
3000 9842
3200 10499
3400 11155
3600 11811
3800 12467
4000 13123
4200 13779
4400 14436
4600 15092
4800 15748
5000 16404

DIP-switch settings

DIP-switch 1: Dip 1-8, Functionality settings

Functionality settings| Dip1| Dip2| Dip3| Dip4| Dip5| Dip6| Dip7| Dip8| DIP-switch 1
---|---|---|---|---|---|---|---|---|---
Light sensor enabled| OFF| | | | | | | | LOGICO2-Grow-CO2-Enrichment-
Controller-16
Light sensor disabled| ON| | | | | | | | LOGICO2-Grow-CO2-Enrichment-
Controller-17
Adaptive CO2- control disabled| | OFF| | | | | | | LOGICO2-Grow-CO2
-Enrichment-Controller-18
Adaptive CO2- control enabled| | ON| | | | | | | LOGICO2-Grow-CO2
-Enrichment-Controller-19
Dosage time 30 sec (Dip2 must be OFF)| | | OFF| | | | | | LOGICO2-Grow-CO2
-Enrichment-Controller-20
Dosage time 60 sec (Dip2 must be OFF)| | | ON| | | | | | LOGICO2-Grow-CO2
-Enrichment-Controller-20
Dip4 Not used| | | | | | | | |
Temperature alarm disabled| | | | | OFF| | | | LOGICO2-Grow-CO2-Enrichment-
Controller-21
Temperature alarm enabled| | | | | ON| | | | LOGICO2-Grow-CO2-Enrichment-
Controller-22
Celsius| | | | | | OFF| | | LOGICO2-Grow-CO2-Enrichment-
Controller-23
Fahrenheit| | | | | | ON| | | LOGICO2-Grow-CO2-Enrichment-
Controller-24
CO2 control hysteresis 40 ppm| | | | | | | OFF| | LOGICO2-Grow-CO2
-Enrichment-Controller-25
CO2 control hysteresis 100 ppm| | | | | | | ON| | LOGICO2-Grow-CO2
-Enrichment-Controller-26
“LOW-indication” disabled| | | | | | | | OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-27
“LOW-indication” enabled| | | | | | | | ON| LOGICO2-Grow-CO2-Enrichment-
Controller-28

DIP-switch 2: Dip 1, 2 and 8, Functionality settings

Functionality settings| Dip1| Dip2| Dip8| DIP-switch 2
---|---|---|---|---
Service mode off| OFF| | | LOGICO2-Grow-CO2-Enrichment-
Controller-30
Service mode on| ON| | | LOGICO2-Grow-CO2-Enrichment-
Controller-31
Automatic calibration disabled| | OFF| | LOGICO2-Grow-CO2-Enrichment-
Controller-32
Automatic calibration enabled| | ON| | LOGICO2-Grow-CO2-Enrichment-
Controller-33
RS485 termination off| | | OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-33
RS485 termination on| | | ON| LOGICO2-Grow-CO2-Enrichment-
Controller-29

DIP-switch 2: Dip 3-7, Communication ID-number

ID- address| Dip3| Dip4| Dip5| Dip6| Dip7| DIP-switch 2
---|---|---|---|---|---|---
ID1| OFF| OFF| OFF| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-36
ID2| ON| OFF| OFF| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-37
ID3| OFF| ON| OFF| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-37
ID4| ON| ON| OFF| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-39
ID5| OFF| OFF| ON| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-40
ID6| ON| OFF| ON| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-41
ID7| OFF| ON| ON| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-42
ID8| ON| ON| ON| OFF| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-43
ID9| OFF| OFF| OFF| ON| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-44
ID10| ON| OFF| OFF| ON| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-45
ID11| OFF| ON| OFF| ON| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-46
ID12| ON| ON| OFF| ON| OFF| LOGICO2-Grow-CO2-Enrichment-
Controller-47

Plug-In Power Supply, Specifications

  • Type: Model FJ-SW2401000N
  • Input voltage: 100-240V AC, 50/60 Hz, max 0.5 A.
  • Output: 24V DC, max 1.0 A
  • Ambient temperature: 0-40°C (+32°F to +102°F)
  • Dimensions (LxWxD): 82.4 x 44.5 x 36.2 mm / 3.2” x 1.8” x 1.4” + input plug

Connection: Enrichment valve 0475
The Enrichment Valve is pre-connected to the connection box and no extra wiring is needed.

Connection diagram: Start fan via external relay with RCB Box 0471

  • Power to External Relay coil, via relay contact in the 0471 RCB Box.
  • Max ratings: 1A/24V AC/DC

LOGICO2-Grow-CO2-Enrichment-Controller-49

Service and maintenance

  1. Service and maintenance should be performed only by authorized professional service agents who are familiar with the Grow CO2 Enrichment Controller and all pertinent safety and service procedures. Contact your representative for the name of the authorized service agent(s) in your area.
  2. Since this also is a safety product we recommend that a function check should be performed on the Grow CO2 Enrichment Controller, by a qualified professional service agent at least once every year.
  3. The Grow CO2 Enrichment Controller has no user serviceable parts. All service work should be performed by an authorized professional agent.
  4. NOTE! Any attempt to service the equipment by unauthorized persons or to perform unauthorized modifications will void the warranty.
  5. The housing must NEVER be opened by unauthorized personnel.
  6. Cleaning is done by use of water on a moistened cloth.

Important
All persons responsible for the use and maintenance of this equipment must read and understand the safety and operating information contained in this guide. Installation and service of this equipment should be performed only by professionals. The function of the equipment will be impaired if it is not properly installed.

Important information regarding third party products
The functionality of LogiCO2’s products are only warranted if connected to LogiCO2’s systems and products. LogiCO2 is not liable for the functionality of any systems if LogiCO2 components or parts are connected to third party products. LogiCO2 permits its products to be connected to external relays controlling ventilation and valves as well as fire alarm panels and building management systems.
Subject to typographical errors and change without prior notice.

Manufactured by:
LogiCO2 International AB Box 9097
400 92 Gothenburg, Sweden

E-mail: info@logico2.com
Web: www.logico2.com

© 2021-12-16 R2.0 LogiCO2 HFE1188 EN

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>