logico2 0475 Enrichment Valve 10W Instructions
- June 9, 2024
- logico2
Table of Contents
Installation Instruction
0475 Enrichment Valve 10W
0475 Enrichment Valve 10W
Enrichment Valve with filter for Grow CO2Enrichment Controller.
Important!
Retain this instruction manual for future reference: Please read these
instructions carefully prior to start-up and use. Failure to follow any of
these instructions could void product warranties. LogiCO2 assumes no
responsibility for claims arising out of improper or careless use or handling
of their products.
Technical specifications
Power supply: Via Grow CO2 Enrichment Controller
ContPower consumption: 420 mA (10 Watt)
Relays: 1A/24V AC/DC
Material: PC/ABS
Operating pressure: 0,15 to 30 bar / 2,2 to 435 Psi
Bursting pressure: >150 bar / 2 175 Psi
Treaded connection: 1/4” -18NPT
Dimensions (WxHxD) Connection box: 78x78x37 mm / 3”x3”x1.5”
Ingress protection: IP55
Function
Enrichment Valve is an accessory for LogiCO2 Grow CO2 Enrichment Controller.
The Grow CO2 Enrichment Controller is a device that measures the concentration
of CO2 in the ambient environment of the room being controlled and
opens/closes the dispenser valve, to achieve a perfect CO2 environment in the
grow room.
Enrichment Valve consists of a magnetic valve with filter, electronics box and
cabling. The Enrichment Valve is designed for usage of CO2 with a pressure of
0,15 to 30 bar or 2,2 to 435 Psi.
Enrichment Valve has a 1 meter Cat5 cable from the electronics box, with a
blue RJ45 connector that is plugged in to the blue cable side of the Grow CO2
Enrichment Controller.
Install the electronics box in a suitable place where it is mechanically
protected. Remove the cover by turning it counterclockwise 1/8 turn to access
the mounting screw holes.
Connection diagram
This connection diagram shows an example of how the different systems can be installed.
Annual function control of the Enrichment Valve with filter
Instruction on how to clean the filter on the Enrichment Valve
Please observe that the flow of CO2 must be turned off manually, by closing
the emergency safety valve – and verify that there is no gas pressure in the
system. This is very important since you are about to open the system to clean
the filter.
Any debris should be caught inside the filter. By using a socket wrench,
carefully remove the filter from the valve and clean it.
After cleaning, make sure that the filtergasket is in place and mount the
filter again firmly.
Carefully open the emergency safety valve to allow the flow of CO2 again.
Annual function and installation check of the Enrichment Valve with
filter
Checklist Enrichment Valve with filter | YES | NO |
---|
Is the Enrichment Valve installed on the downside from the emergency safety
valve?| |
Does the red diode on the Enrichment Valve turn on and off when the valve is
dispensing/not dispensing CO2 gas?| |
Has the filter on the Enrichment Valve been cleaned?| |
Enrichment Valve installed with filter
Manufactured by:
LogiCO2 International AB
Box 9097
400 92 Gothenburg, Sweden
E-mail: info@logico2.com
Web: www.logico2.com
© 2022-01-10 R2.0 LogiCO2 HFE1216 EN