BRESSER 7009975 Water Sensor Instruction Manual

June 9, 2024
BRESSER

BRESSER 7009975 Water Sensor

Instruction

IMPORTANT NOTE

  • Read and keep these instructions.
  • Do not cover the ventilation holes with any items such as newspapers, curtains etc.
  • Do not clean the unit with abrasive or corrosive materials.
  • Do not tamper with the unit’s internal components. This invalidates the warranty.
  • Only use fresh batteries. Do not mix new and old batteries.
  • Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
  • Attention! Please dispose of used unit or batteries in an ecologically safe manner.
  • Technical specifications and user manual contents for this product are subject to change without notice.

CAUTION

  • Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type.
  • Battery cannot be subjected to high or low ex-treme temperatures, low air pressure at high altitude duning use, storage or transportation.
  • Replacement of a battery with an in correct type that can result in an explosion or the leakage of flammable liquid or gas.
  • Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion.
  • Leaving a battery in an extremely high temper-ature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas.
  • A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.
  • An appliance is only suitable for mounting at height ≤ 2m

OVERVIEW

  1. Buzzer
  2. LED indicator
  3. Sensor contact wall mounting holder
  4. Water sensor
  5. Wall mounting holder
  6. [CHANNEL], slide switch
  7. [RESET] key
  8. Battery compartment

GETTING STARTED

  1. Remove the battery door.
  2. Slide the [CHANNEL] slide switch to assign the sensor to a channel from channel 1,2,3,4,5,6 or 7.
  3. Insert 2 x AA size batteries into the battery compartment according to the polarity mark on the battery compartment..
  4. Close the battery door.
  5. After inserting batteries, the transmission status LED will light up 1 sec

NOTE:

  • Ensure to assign different channels of different sensors, in case you need to pair more than one sensors.
  • Once the channel is assigned to a wireless waster leaksensor, you can only change it by removing the batteries or resetting the unit.
  • Avoid placing the sensor in direct sunlight, rain or snow

PAIRING THE WIRELESS SENSORS

WITH THE CONSOLE
The console will automatically search and connect to your wireless sensor(s). Once your sensor(s) pair up successful, the sensor(s) signal strength indication and weather information will appear on your console display.

NOTE:
During signal transmission, the LED indicator of the sensor will flash.

WHEN DETECTED THE WATER LEAK
Once the water leak sensor detected a water leak, the sensor emits a 90dB alarm and trans-mits data to the console once every 1 minute. After you address the cause of the alert and wipe dry the water sensor, the water sensor will detect “dry” in its placed area, the water leak sensor will auto stop the alarm sound after then.

NOTE:
You can mute the water leak sensor by removing the batteries from the battery compartment.

HOW TO PLACE THE SENSOR

  • Choose a location where water leaks are likely to occur. For the most part, this sensor will be placed near water sources, or anywhere you think leaks are possible.
  • Choose a location that shields the sensor from direct sunlight for an accurate reading.
  • Minimize obstructions such as doors, walls, furniture, etc. And make sure the transmission is within 150 meters approx.
  • The main sensor unit must hang with the wall mount hole, but the detection unit can hand it with wall mount hole or place it directly on flat surface, and make sure the transmission is within 150 meters approx.

RESET THE SENSOR
In case of malfunction, press the [RESET] button to reset the sensor.

SPECIFICATIONS

Dimensions (WxHxD) 125 x 58 x 19 mm
Weight 144g (with batteries)
Main power 2 x AA size 1.5V batteries (Lithium battery recommended for low

temperature environment)
Weather data| Water leak
RF frequency| 868MHz
RF transmission range| 150m (490 feet) straight distance
Sensor detecting interval| 3 seconds after the water leak detected
---|---
Sensor reporting interval| 60 seconds after the water leak detected
Number of channels| 7 (CH1 ~ 7)
RF normal Transmis- sion interval| 60 seconds
Operating temperature range| -20 ~ 60°C (-4 ~ 140°F)
Operating humidity range| RH 1% to 99 %

HANG THE MAIN SENSOR WITH THE WALL MOUNT HOLE

BRESSER-7009975-Water-Sensor-fig- \(4\)

LAY THE DETECTION UNIT ON THE GROUND OR MOUNT IT ON A WALL

NOTES ON CLEANING

  • Remove the batteries before cleaning.
  • Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
  • Protect the device from dust and moisture.

WARRANTY & SERVICE

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms and details of our services at www.bresser.de/warranty_terms. Would you like detailed instructions for this product in a particular language? Then visit our website via the link below (QR code) for available versions.

www.bresser.de/warranty_terms.

DISPOSAL

  • Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-dis-posal service or environmental authority for information on the proper disposal.
  • Do not dispose of electronic devices in the household garbage! As per the Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.
  • In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive. Batteries that contain toxins are marked with a sign and a chemical symbol.
  1. battery contains cadmium
  2. battery contains mercury
  3. battery contains lead

EC DECLARATION OF CONFORMITY

Hereby, Bresser GmbH declares that the equipment type with part number: 7009975 complies with

Directive:
2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
www.bresser.de/download/7009975/CE/7009975_CE.pdf

UKCA DECLARATION OF CONFORMITY
Bresser UK Ltd. has issued a „Declaration of Conformity“following applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address:
www.bresser.de/download/7709975/UKCA/7009975_UKCA.pdf

Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals