Arktic 232019 REFRIGERATOR COUNTERS User Manual

June 9, 2024
Arktic

Arktic 232019 REFRIGERATOR COUNTERS User Manual

Arktic-232019-REFRIGERATOR-COUNTERS-PRODUCT

You should read this user manual carefully before using the appliance.

  • Keep this manual with the appliance.
  • For indoor use only.Arktic-232019-REFRIGERATOR-COUNTERS-FIG-2

Dear Customer,
Thank you for purchasing this Arktic appliance. Before using the appliance for the first time, please read this manual carefully, paying particular attention to the safety regulations outlined below.

Safety regulations

  • This appliance is intended for commercial use only.

  • The appliance must only be used for the purpose for which it was intended and designed. The manufacturer is not liable for any damage caused by incorrect operation and improper use.

  • Keep the appliance and electrical plug away from water and any other liquids. In the event that the appliance should fall into the water, immediately remove the plug from the socket and do not use it until the appliance has been checked by a certified technician. Failure to follow these instructions could cause a risk to lives.

  • Never attempt to open the casing of the appliance yourself.

  • Do not insert any objects in the casing of the appliance.

  • Do not touch the plug with wet or damp hands.

  • The danger

  • Regularly check the power plug and cord for any damage. If the power plug or power cord is damaged, it must be replaced by a service agent or similarly qualified persons in order to avoid danger or injury.

  • Make sure the cord does not come in contact with sharp or hot objects and keep it away from an open fire. To pull the plug out of the socket, always pull on the plug and not on the cord.

  • Ensure that the cord (or extension cord) is positioned so that it will not cause a trip hazard.

  • Always keep an eye on the appliance when in use.

  • Warning! As long as the plug is in the socket the appliance is connected to the power source.

  • Turn off the appliance before pulling the plug out of the socket.

  • Never carry the appliance by the cord.

  • Do not use any extra devices that are not supplied along with the appliance.

  • Only connect the appliance to an electrical outlet with the voltage and frequency mentioned on the appliance label.

  • Connect the power plug to an easily accessible electrical outlet so that in case of an emergency the appliance can be unplugged immediately. To completely switch off the appliance pull the power plug out of the electrical outlet.

  • Always turn the appliance off before disconnecting the plug. of electric shock! Do not attempt to repair the appliance yourself. In case of malfunctions, repairs are to be conducted by qualified personnel only.

  • Never use a damaged appliance! Disconnect the appliance from the electrical outlet and contact the retailer if it is damaged.
    Warning! Do not immerse the electrical parts of the appliance in water or other liquids. Never hold the appliance under running water.

  • Never use accessories other than those recommended by the manufacturer. Failure to do so could pose a safety risk to the user and could damage the appliance. Only use original parts and accessories.

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.

  • This appliance must not be used by children under any circumstances.

  • Keep the appliance and its cord out of reach of children.

  • Always disconnect the appliance from the mains if it is left unattended or is not in use, and before assembly, disassembly or cleaning.

  • Never leave the appliance unattended during use.

Special safety regulations

  • This appliance is designed for short-time storage of cake for a display to customers under low temperatures. Do not store any other materials in the appliance. Do not place any dangerous products, such as fuel, alcohol, paint, flammable or explosives, etc. inside or near the appliance. No medicine is allowed to keep inside the appliance.
  • Products put in the appliance must be already pre-cooled. Otherwise, moisture evaporating while cooling food products can condensate inside the cooling compartment, which is natural and does not indicate any malfunction of the appliance.
  • This appliance must be installed, commissioned, and serviced by a qualified or trained person. And this appliance is intended to be used by trained or qualified personnel such as the kitchen or bar staff.
  • WARNING: Do not use mechanical devices or other means to accelerate the defrosting than those recommended by the manufacturer.
  • WARNING : Do not damage the refrigerant circuit.

Caution! Risk of fire! The refrigerant used is in appliances. It is a highly flam-mable refrigerant.

  • WARNING: Keep all ventilation openings in the appliance enclosure clear of obstruction. Provide sufficient ventilation in the surrounding structure when building in. Never block the airflow suction and air outlet in order to keep air circulation.
  • ARNING: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
  • Place the appliance on a clean, stable, dry, level surface only.
  • Keep the appliance away from any hot surfaces and open flames. Protect the appliance against heat, dust, direct sunlight, moisture, dripping, and splashing water.
  • Allow at least 50 cm surrounding spacing for ventilation purposes during use.
  • Do not use hard utensils to hit the glass surface. Do not use a water jet, flush directly with water or steam cleaner as the parts will get wet and an electric shock might result.
  • Do not place articles on top of the appliance. Do not place objects with open sources of fire (e.g. candles) on top or beside the appliance. Do not place objects filled with water (e.g. vases) on or near the appliance.
  • Never cover the appliance during use. This may cause a fire hazard.
  • Do not wash the appliance with water. Washing can cause leakages and increase the risk of electric shock.
  • Do not make any additional openings on the appliance. Do not install any gadgets in the appli-ance.
  • Do not overload the shelves inside to avoid damage. Max. loading of each shelf is about 40kg. Place the food evenly on each shelf.
  • Do not attempt to climb up to the top of the appliance.

Intended use
Cooling appliances are designed for short-time storage of food at a lower temperature for a display to the customer. Freezing appliances are designed to store fresh food with an extended best-before date – even for several months, depending on the type of food and storage temperature.

  • This appliance is designed for use in restaurants, canteens, and commercial enterprises such as bakeries, supermarkets, etc.
  • This appliance is intended for professional use.
  • This appliance is intended for indoor use.
  • Use the appliance only as described in the manual.

Grounding installation
This appliance is classified as a protection class I appliance and must be connected to protective ground. Grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

  • Any other use may lead to damage to the appli-ance, other user property, or personal injury.
  • No liability will be accepted for damage resulting from improper use or non-compliance with this manual.

Note: products put in the appliance must be already pre-cooled. Otherwise, moisture evaporates while cooling food products can condensate inside the cooling compartment.
Otherwise, it will contaminate with other food. Do not store any medications in the appliance. Operating the appliance for any other purpose means misuse of the appliance.In case of electrical or refrigeration failure, a service agent authorized by the manufacturer or profes-sional maintenance staff shall be responsible for the maintenance work in case of danger or expanded failure.

Technical data

Common features of cooling and freezing cabinets:

  • Inner and outer housing are made of high-quality stainless steel, except the outer rear cover which is made of galvanized steel.
  • Static cooling.
  • Digital display and electronic thermostat.
  • Embraco compressor.
  • Comfortable curved door handle.
Model 232019 232026 232767
Dimensions [mm] 900x700x(H)880 1365x700x(H)880 900x700x(H)880
Chamber Dimensions [mm] 830x595x(H)500 1295x595x(H)500 830x595x(H)500
Numbers/ dimensions of shelves [mm] 2x 335×570 3x 335×570
Numbers/Dimensions of drawers [mm] 4x 300x545x(H)140
Capacity [l] 300 380 300
Power [W] 220 220 220
Voltage/ Frequency 230V ~50 Hz 230V ~50 Hz 230V ~50 Hz
Energy Use daily/ annum [kWh] 1,16 / 423 1,6 / 529 1,45 / 584
Refrigerant/ Amount [kg] R600a / 0,06 R600a / 0,07 R600a / 0,06
Climate class 4 4 4
EEI C D C
Temp. range [°C] -2 / +8 -2 / +8 -2 / +8
Weight [kg] 70 91 80
Model 232804 232811 232743
--- --- --- ---
Dimensions [mm] 900 x 700 x 888 1365x700x(H)888 900x700x(H)888
Chamber Dimensions [mm] 830x595x(H)500 1295x595x(H)500 830x595x(H)500
Numbers/Dimensions of shelves [mm] 2x 335×570 3x 335×570 2x 335×570
Capacity Gross [l] 300 380 300
Power [W] 310 310 310
Voltage/ Frequency 230V ~50 Hz 230V ~50 Hz 230V ~50 Hz
Energy Use daily/Annum [kWh] 2,12 / 774 2,55 / 931 2,12 / 774
Refrigerant/Amount [kg] R600a / 0,06 R600a / 0,07 R600a / 0,06
Climate class 4 4 4
EEI C D
Temp. range [°C] -2 / +8 -2 / +8 -2 / +8
Weight [kg] 68 87 75
Model 232781 232798 232880
--- --- --- ---
Dimensions [mm] 900x700x(H)1300 1365x700x(H)1300 900x700x(H)1040

1365x700x(H)1040
Chamber Dimen- sions [mm]| 830x595x(H)500| 1295x595x(H)500| 830x595x(H)500| 1295x595x(H)500
Capacity Gross [l]| 300| 380| 300| 380
Power [W]| 310| 310| 310| 310
Voltage/Frequency| 230V ~50 Hz| 230V ~50 Hz| 230V ~50 Hz| 230V ~50 Hz
Energy Use daily/ Annum [kWh]| 2,12 / 773| 2,12 / 773| 2,12 / 773| 2,55 / 930
Refrigerant/Amount [kg]| R600a / 0,06| R600a / 0,06| R600a / 0,06| R600a / 0,07
Climate class| 4| 4| 4| 4
Temp. range [°C]| -2 / +8| -2 / +8| -2 / +8| -2 / +8
Weight [kg]| 80| 110| 75| 105
Model| 232859| 232873| 232842| 232033
---|---|---|---|---
Dimensions [mm]| 900x700x(H)1100| 1365 x 700 x 1100| 2020x800x(H)1110| 1365 x 700 x 1030

1405 x 335 x 255

Chamber Dimen- sions [mm]| 830x595x(H)500| 1295x595x(H)500| 980x670x(H)570| –
Numbers/Dimen- sions of shelves [mm]| ****

2x 335×570

| ****

3x 335×570

| ****

2x 600×400

| ****

Numbers/Dimen- sions of drawers [mm]| ****

| ****

| ****

7x 400x620x(H)65

| ****

Capacity Gross [l]| 300| 380| 280| 380 + 40
Power [W]| 310| 310| 250| 220 + 180
Voltage/Frequency| 230V ~50 Hz| 230V ~50 Hz| 230V ~50 Hz| 230V ~50 Hz
Energy Use daily/ annum [kWh]| 2,12 / 773| 2,55 / 930| 1,38 / 503| 1,6 / 584
Refrigerant/Amount [kg]| R600a / 0,06| R600a / 0,07| R600a / 0,12| R600a / 0,07

R600a / 0,04

Climate class| 4| 4| 4| 4
EEI| –| –| C| D
Temp. range [°C]| -2 / +8| -2 / +8| -2 / +8| -2 / +8
Weight [kg]| 94| 180| 367| 190 + 41

Appliances are designed to work efficiently on an ambient of +30 °C with 55% relative humidity.
Climate class indicates the maximum ambient temperature at the place of appliance installation. Compliance with the determined maximum ambient temperature ensures that the internal temperature inside the appliance is maintained and products are safely stored. Remember that the too-high ambient temperature of the environment in which the cooling or freezing cabinet is placed may influence power consumption and have an impact on the storage safety of the products placed inside. The manufacturer and dealer are not liable for any inaccuracies due to printing errors or transcription, in this manual. In line with our policy of continuous improvement products, we reserve the right to make modifications to the product, packaging, and specifications contained in the Documentation without prior notice.

Before the first use of Transport

  • A special package box is required for the delivery of the equipment. Keep the equipment level during transportation and handling.
  • Please carefully check the package box after receiving the product to ensure that the equipment is not damaged during transportation.
  • Check for the completeness of the equipment. In case of incomplete delivery and damages. Please contact the supplier (See ==> Warranty).
  • When removing the package box, carefully move away the wood plate in case of scratch the equip-ment.
  • In case the equipment tilts during transportation and handling, the lubricant in the com-pressor may flow into the cooling loop. Therefore, in order to ensure the lubricant flows back to the compressor, it is necessary to keep the equipment level for 24 hours before plugging in the equipment and starting to work.
  • Do not throw away the package randomly. Please dispose of it as per relevant local rules and regulations.
  • Clean all components as described (See ==> Cleaning and Maintenance).
  • Place all the shelves inside the appliance. NOTE: Due to manufacturing residues, the appli-ance may emit a slight odor in the first few cycles. This is normal and does not indicate any defect or hazard. Make sure the appliance is well-ventilated.
  • Turn on the lighting switch, and check the light is normal.
  • The digital temperature controller is delivered with default parameters. Do not alter the parameters casually except for special needs.
  • When running for the first time, it should run without load for 2 hours to ensure the refrigeration system is working normally. Only when the temperature within the appliance is reduced within the indicated scope can the food be put into the appliance.
  • Don’t put too much food in the appliance to prevent instantaneous high load. The food shall not block the air outlet and air inlet. Nor shall it be close to the side glass. Otherwise, it will lead to condensation.
  • To keep the taste of the food, please have the equipment running 24 hours a day.
  • During the frosting process, the temperature of the appliance may rise slightly. When the frosting end, it will return to normal.

ATTENTION: During transport, avoid skewing the unit from the vertical by an angle greater than 30 °, If necessary, wait approximately 3-4 hours before running, until the oil flows to the unit. Otherwise, the condensing unit may be damaged.

Levelling
To ensure correct functioning it is important to level the appliance. Correct leveling allows for the reduction of vibration generated by the unit in operation. Thoroughly check the leveling with the use of a spirit level.
CAUTION!
To ensure the proper functioning of the cooling/freezing appliance, strictly follow the instructions below:

  • Do not put the appliance in a place exposed to direct sunlight and near appliances emitting radiation, such as heat lamps, stoves, radiators, etc.
  • Avoid integrating or building over the appliance.
  • Do not place any objects on the top of the appli-ance housing where the refrigerating unit is lo-cated.

Minimum distance from walls
In order to ensure proper operation of the appli-ance, during the installation remember to ensure minimum distance from walls in accordance with the drawings below. Remember to ensure the appropriate amount of space in front of the appliance as well – it is necessary for easy opening of the cooling/freezing chamber doors.

Connection to the power supply
The connection to the power source must be made by trained and qualified service technicians. The power cable is supplied with the cooling/freezing Prior to making the connection, make sure:

  • The supply voltage corresponds to the appliance voltage of 230 V / 50 Hz / 1 ph. Proper operation of the appliance requires that the voltage should be within ± 6% of the rated voltage.
  • The electrical system used to power the appli-ance must be suitable for the rated parameters of the appliance to be installed.

Connection stages:

  • Install the thermomagnetic circuit breaker suitable for the rated output power of the appliance to be installed.
  • Connect the counter to the output on the thermo-magnetic circuit breaker.
  • Do not place the appliance in a room with relative-ly high humidity (water can liquify on the housing).
  • Do not place the appliance in narrow recesses (if there is no air circulation, the appliance will not function properly).
  • Do not cover ventilation openings located on the housing.
  • Do not place the appliances back to back (they will not operate properly).
  • Ensure that the room where the appliance is placed is properly ventilated, also outside of working hours; it is crucial for the proper operation of the refrigerating unit.
  • counter. A thermomagnetic circuit breaker (field supply) must be installed between the socket and the power cable of the appliance.
  • The electronic system connected to the counter complies with applicable requirements. Electri-cal connections and installation of the thermo-magnetic circuit breaker have been performed by a qualified person.
  • Make sure the counter is operational (signaled by an indicator lamp).

How to use

Placing trays and containers in the refrigerant’s/freezer’s chamber Never stack food items on top of each other. Divide them evenly on the tray or GN container.

Arktic-232019-REFRIGERATOR-COUNTERS-FIG-4

Keep vertical space between trays and/or GN containers
In order to ensure optimum circulation of hot air in the refrigerant’s/freezer’s chamber, a minimum vertical distance of 40 mm between the trays or GN containers is required.

Arktic-232019-REFRIGERATOR-COUNTERS-FIG-5

Positioning of trays and/or GN containers in the refrigerant’s/freezer’s chamber
To ensure optimum cold air circulation:

  • Don’t position the tray or GN container against the fan
  • Position them evenly and in the middle of the chamberArktic-232019-REFRIGERATOR-COUNTERS-FIG-6

Automatic defrosting
The appliance is equipped with an automatic de-frosting system with default parameters, whereas the number, duration, and time intervals between subsequent defrosting cycles can be set in the control panel. This process should be conducted by qualified staff; in individual cases, the appliance may require manual defrosting, which can be set in the control panel or you can switch the appliance off and

First use
Before starting the use of a new appliance, it should be opened and aired. Then, its interior should be cleaned with warm water. After connecting to the mains, press the power button on the control panel (green signal light will be lit). The appliance will start. A micro-computer controller installed in the control panel

Operation
Before placing the food product in the appliance chamber, wait until it reaches the requested tem-perature. All food products placed inside the appli- ance should be pre-cooled to the internal operating temperature of the chamber. Do not place inside the appliance any hot food just taken out of the oven or stove. Before placing the food in the appliance, check whether the actual temperature inside the chamber corresponds to the required temper- ature. The temperature of deep-frozen products should not exceed -18°C. Placing in the appliance any products that had not been cooled down before wait until the ice melts (the time required for this process depends on the room conditions and the amount of ice).

In the case of appliances designed for frozen or packed food, it is recommended to fully clean and defrost the appliance once a month. It is recommended to clean the external housing of the appliance and the internal part of the door, especially near the gasket. may adjust temperature ranges automatically. The smart digital controller operates in the following way: when the temperature increases and a set point is reached, a compressor is switched on, then it is switched off, and when the temperature reaches a set value again. may result in their spoiling or disturb the operation of the appliance. To ensure proper operation of the appliance, the products have to be placed in a way that does not block the circulation of cooled air inside the appliance. When the door is open, cool air escapes from the chamber, therefore it is recommended to limit the door opening frequency to the necessary minimum. Ensure the door is open only for a period necessary to take out or put the food inside. Do not place any products on the top of the appliance.

Control panel

Arktic-232019-REFRIGERATOR-COUNTERS-FIG-7Arktic-232019-REFRIGERATOR-COUNTERS-FIG-8

Operation of control panel Changing the set value

  • In order to display the set value, press and immediately release the [SET/MUTE] button.
  • Press and hold the [SET/MUTE] button for at least 1 second to change the set value. The current set value will be displayed.
  • To change the set value, press the [UP/SWITCH] or [DOWN/DEFROSTING] arrows. To store the new set value, press the [SET/MUTE] button again or wait 15 seconds.

Setting the default parameters To reset the default parameters:

  • disconnect power from the instrument;
  • reconnect power while holding the [SET/MUTE] and [DOWN/DEFROSTING] buttons;
  • the display will show the message “CF”;
  • after a few seconds, the instrument starts operating with the default configuration. Any different parameter settings will need to be updated.

Warnings: running this procedure overwrites any custom parameter settings.

Turn on/off continuous cycle
To turn the ON/OFF continuous cycle, press and hold the [UP/SWITCH] + [DOWN/DEFROSTING] buttons for more than 3 seconds. “CC” will be displayed.

Manual defrosting
To start the manual defrosting, press and hold the DEF [DOWN/DEFROSTING] button for more than 3 seconds.

Alarms
  • Alarm Error
  • EE Unit parameter error
  • EtC Clock alarm
  • HI Maximum temperature alert
  • LO Minimum temperature alert
  • IA External alert
  • cht Dirty condenser alarm
  • dOr Door opened

Cleaning and maintenance

CAUTION : Before cleaning and/or maintenance make sure that the appliance is NOT connected to the power supply. The maintenance of the appliance should be performed by qualified and certified personnel

Cleaning
The trouble-free operation and service life of the appliance are essentially dependent on proper maintenance according to the schedule. Daily cleaning of the cooling/freezing chamber is essential to prevent bacterial growth. Before cleaning, manually defrost the appliance with the door open and the drain plug removed. Follow the instructions
below:

  •  Do not use direct water jet and water under pressure to clean the appliance as it can damage the electrical wiring
  • Do not use any metal objects to remove ice accumulated inside the chamber, as it may scratch and/or damage its internal surfaces.
  • Always use lukewarm (not hot!) water with a mild detergent for cleaning and a soft cloth for drying of the appliance.
  • Avoid using corrosive substances that contain chlorine (and its solutions), caustic soda, hydrochloric acid, acetum, bleach, etc.

Cleaning the condenser
Before cleaning of the condenser make sure that the appliance is NOT connected to the power supply. To ensure a trouble-free and long-term operation of the condenser unit it is necessary to clean the condenser at least once a month. Use a brush with long bristles for condenser cleaning. It is recommended to wear protective gloves during the cleaning
of the condenser – it reduces the risk of injury  It is recommended to wear protective gloves during the cleaning of the appliance. and cutting with its sharp edges. A dirty condenser unit reduces motor power which increases the power consumption of the appliance. Take care not to damage the cooling system. It is recommended to wear protective gloves during the cleaning of the appliance – the risk of injury.

Maintenance

Remember to check the technical condition of the appliance regularly (at least once a year) – the overhaul should be carried out by qualified and licensed personnel.
Check whether:

  • The condensate drainage system operates prop-erly.
  • There is no refrigerant or freezing agent leakage and the cooling system operates prop-erly.
  • The technical condition of the wiring system is absolutely safe.
  • The gasket is correctly placed and the door closes properly.
  • The condenser is clean.
  • The digital control panel operates properly.

Food storage
In order to ensure the best possible operation of the cabinet, the following rules should be observed:

  • Place food products in the cabinet when it reaches the requested set temperature (visible on the display).
  • Do not place warm food and liquids inside the appliance.
  • If possible, the food should be wrapped or secured in any other way (air circulation speeds up the drying of food)
  • Do not block air circulation inside the chamber (remove unnecessary obstructions).
  • Avoid frequent and prolonged opening of the door.
  • Wait a while before opening the door again, if it has just been closed (suction force created in the chamber after the door is closed will hinder its subsequent opening, which is a standard phenomenon).

Troubleshooting

A defect in the appliance is often caused by problems that can be easily solved without having to contact a service technician. In such cases, the following activities should be performed. If the appliance does not work, check whether:

  • The plug is firmly secured in the power outlet.
  • The power cord is not damaged.

If the requested temperature is not obtained, check whether:

  • The controller switch is on,
  • The settings on the electronic control panel are correct (see Maintenance),
  • The appliance is undergoing a defrosting cycle or whether the defrosting cycle just ended,
  • The condenser is covered with dust,
  • The appliance is located close to a source of heat or the airflow around the condensation unit is not obstructed,
  • The products stored or other objects make it impossible to close the door properly,
  • The appliance is operating in abnormal working conditions (excessive load, too many products inside, products are placed in a manner which ob- structs air circulation).

If the appliance generates excessive noise, check whether:

  • There are no loose screws in the frame, In case the appliance still makes excessive noise
  • The appliance is placed on a stable surface and is after performing the above activities, please con- properly leveled. tact technical service. Be ready to provide the following information
  • The trade name of the model as well as the serial number (this can be found on the rating plate),
  • Error codes appear on the display of the control panel.

Highly improbable risk
In case of fire, disconnect the appliance from the mains if possible and use a powder extinguisher.

Warranty

Any defect affecting the functionality of the appliance which becomes apparent within one year after purchase will be repaired by free repair or replacement provided the appliance has been used and maintained in accordance with the instructions and has not been abused or misused in any way. Your statutory rights are not affected. If the appli-ance is claimed under warranty, a state where and when it was purchased and include proof of purchase (e.g. receipt). In line with our policy of continuous product devel-opment, we reserve the right to change the product, packaging, and documentation specifications without notice.

Discarding & Environment
When decommissioning the appliance, the product must not be disposed of with other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point. Failure to follow this rule may be penalized in accordance with applicable regulations on waste disposal. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural re-sources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste for recycling, please contact your local waste collection company. The manufacturers and importers do not take responsibility for recycling, treatment, and ecological disposal, either directly or through a public system.

Hendi Food Service Equipment GmbH Gewerbegebiet Ehring 15
5112 Lamprechtshausen, Austria
Tel: +43 (0) 6274 200 10 0
Email: [email protected]Changes, printing, and typesetting errors reserved.© 2020 Hendi BV Rhenen – The Netherlands Ver: 21-04-2020

Download PDF:Arktic 232019 REFRIGERATOR COUNTERS User Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals