SUNELL SN-IPR8xxxCN Eyeball Network Camera User Guide
- June 9, 2024
- SUNELL
Table of Contents
SUNELL SN-IPR8xxxCN Eyeball Network Camera User Guide
Precautions
Fully understand this document before using this device, and strictly observe rules in this document when using this device. If you install this device in public places, provide the tip “You have entered the area of electronic surveillance” in an eye-catching place. Failure to correctly use electrical products may cause fire and severe injuries.
WARNING
- Strictly observe installation requirements when installing the device. The manufacturer shall not be held responsible for device damage caused by users’ non-conformance to these requirements.
- Strictly conform to local electrical safety standards and use power adapters that are marked with the LPS standard when installing and using this device. Otherwise, this device may be damaged.
- Use accessories delivered with this device. The voltage must meet input voltage requirements for this device.
- If this device is installed in places with unsteady voltage, ground this device to discharge high energy such as electrical surges in order to prevent the power supply from burning out.
- When this device is in use, ensure that no water or any liquid flows into the device. If water or liquid unexpectedly flows into the device, immediately power off the device and disconnect all cables (such as power cables and network cables) from this device.
- Do not focus strong light (such as lighted bulbs or sunlight) on this device. Otherwise, the service life of the image sensor may be shortened.
- If this device is installed in places where thunder and lightning frequently occur, ground the device nearby to discharge high energy such as thunder strikes in order to prevent device damage
CAUTION
- Avoid heavy loads, intensive shakes, and soaking to prevent damages during transportation and storage. The warranty does not cover any device damage that is caused during secondary packaging and transportation after the original packaging is taken apart.
- Protect this device from fall-down and intensive strikes, keep the device away from magnetic field interference, and do not install the device in places with shaking surfaces or under shocks.
- Clean the device with a soft dry cloth. For stubborn dirt, dip the cloth into slight neutral cleanser, gently wipe the dirt with the cloth, and then dry the device.
- Do not jam the ventilation opening. Follow the installation instructions provided in this document when installing the device.
- Keep the device away from heat sources such as radiators, electric heaters, or other heat equipment.
- Keep the device away from moist, dusty, extremely hot or cold places, or places with strong electric radiation.
- If the device is installed outdoors, take insect- and moistureproof measures to avoid circuit board corrosion that can affect monitoring.
- Remove the power plug if the device is idle for a long time.
- Before unpacking, check whether the fragile sticker is damaged. If the fragile sticker is damaged, contact customer services or sales personnel. The manufacturer shall not be held responsible for any artificial damage of the fragile sticker.
Special Announcement
- All complete products sold by the manufacturer are delivered along with nameplates, quick setup guide and accessories after strict inspection. The manufacturer shall not be held responsible for counterfeit products.
- The manufacturer will update this manual according to product function enhancement or changes and regularly update the software and hardware described in this manual. Update information will be added to new versions of this manual without prior notice.
- This manual may contain misprints, technology information that is not accurate enough, or product function and operation description that is slightly inconsistent with the actual product, the final interpretation of company is as a standard.
- This manual is only for reference and does not ensure that the information is totally consistent with the actual product. For consistency, see the actual product.
Open Package Examination
Open the package, check the appearance of product for no obvious damage, and confirm the item list for table 1-1 is consistent.
Table 1-1 Packing list
Component | Quantity | Remark |
---|---|---|
Eyeball Network Camera | 1 | |
Quick Setup Guide | 1 | |
Installation location sticker | 1 | |
L Hex wrench | 1 | |
White stainless self-tapping screw PA4.0×35mm | 3 | Choice one of two |
White stainless self-tapping screw PA3.0×35mm | 3 | |
Network access port protective cover | 3 | |
Terminal block | 2 | Optional |
Plastic anchor φ5.6×29mm | 1 | |
Waterproof rubber seal | 1 |
Device Structure
Device Ports
Different devices may have different multi-head cables; Please refer to the actual product.
Table 2-1 Multi-head cable 1 description
ID | Core | Description | Remark |
---|---|---|---|
1 | Network access port | Connects to a standard Ethernet cable or PoE . The |
green light is on, the network connection is normal; the yellow light flashes
when the data is transmitted. Some models maybe not have the lights; Please
refer to the actual product.| Support PoE supply.
2| Audio output| Connects to an external audio device such as a speaker.|
Applied for camera with audio function
3| Audio input port| Receives an analog audio signal from devices such as a
sound pickup device.
4| Reset button| Long press the reset button for 5 seconds to restore the
original settings.|
5| Power supply (DC 12V)| Connects to a 12V direct current (DC) power supply.|
6| G| Alarm output COM| Applied for alarm function
OUT| Alarm output terminal
G| Alarm input COM
IN| Alarm input terminal
Figure 2-2 multi-head cable 2
Table 2-2 Multi-head cable 2 description
ID | Core | Description | Remark |
---|---|---|---|
1 | Network access port | Connects to a standard Ethernet cable or PoE . The |
green light is on, the network connection is normal; the yellow light flashes
when the data is transmitted.Some models maybe not have the lights; Please
refer to actual product.| Support PoE supply.
2| Power supply (DC 12V)| Connects to a 12V direct current (DC) power supply.|
3| Reset button| Long press the reset button for 5s to restore the original
settings.|
Camera Dimensions
Different devices may have different dimensions; Please refer to the actual product.
Figure 2-3 Dimensions 1(Unit: mm)
Figure 2-4 Dimensions 2(Unit: mm)
Device Installation
Installation Steps:
Step 1 Open a package, take out the camera and the accessories. Step 2 Stick
the Installation location sticker on the ceiling or wall. Drill three holes
based on the marks on the sticker. Drive the plastic anchors into the holes,
as shown in figure 3-1.
Step 3 Fix the camera to the mounting surface by using selftapping screws, as shown in figure 3-2.
Step 4 Connect the multi-connector cable.
You can route cables from the top or from the side. If you use the top routing
method, drill a hole in the surface first. If you use the side routing method.
When you route cables from the side, please route the multi-head cable out
from the side outlet at the bottom of the camera, as shown in figure 3-3.
Step 5 Loosen the screws for two to three circles, install the dome shell and
the compression ring on the mounting base, adjust the position so that the
camera faces the monitored area, then tighten the screw, as shown in figure
3-4.
Step 6 Tighten the screws in both sides on the base with L Hex wrench, as
shown in figure 3-5.
Quick Configuration(e.g IE)
Login
Step 1 Open the Internet Explorer, input the IP address of IP camera
(default value: 192.168.0.120) in the address box, and press Enter. The login
page is displayed as shown in figure 4-1 .
Step 2 Input the user name and password.
NOTE
- The default user name and password are both admin.
- Change the password when user logs into the system for first time to ensure system security.
- If you want to restart the device after modifying password, please wait three minutes before restarting.
- You can change the system display language on the login page.
Figure 4-1 Login
Step3 Click Login, the main page is displayed.
Modify IP address
Choose Configuration > Device > Local Network, the Local Network page is
displayed. Enter the IP address in the IP Address box and click Apply as shown
in figure 4-2. After the IP address is set successfully, please use the new IP
address to log in the Web interface.
Figure 4-2 Local Network
Browsing Video
To ensure the real-time video can be played properly, you must perform the
following operations when you login the web for the first time:
Step 1 the Internet Explorer. Choose Tools > Internet options > Security
Trusted sites > Sites, in the display dialog box, click Add, as shown in figure 4-3
Figure 4-3 Adding a trusted site
Step 2 In the Internet Explorer, choose Tool > Internet Options > Security > Customer level, and set Download unsigned ActiveX control and initialize and script ActiveX controls not marked as safe for scripting under ActiveX controls and plug-ins to Enable, as shown in figure 4-4.
Figure 4-4 Configuring ActiveX control and plug-in
Step 3 Download and install the player control as prompted.
NOTE
If the repair tips displayed when installing the control , please ignore the
prompt, and continue the installation, the login page is displayed when the
control is loaded. To browse a real-time video, click Live Video. The Live
Video page is displayed, as shown in figure 4-5.
Figure 4-5 Live Video
- Personnel Count: User can query the data of personnel count, through year, month, day. The statistics can be downloaded. The data can be shown by line chart, histogram, list.
- AI Live video: Click the icon to view the snapshots of human face or license plate (click “Face” or “Plate” to switch ).The bottom page will show the captured images of vehicle and human face.
Figure 4-6 Installation of personnel count
CAUTION
If user requires higher accuracy of personnel count, we recommend the user to
install camera and draw the line following as figure 4-6. For better capture
performance, it is recommended to use 6mm focus length lens or above.
Intelligent Analysis
At “Configuration > Intelligent Analysis” interface, user can set the
parameters of Perimeter, Single Virtual Fence, Double Virtual Fence, Multi
Loiter, Converse and Personnel Count, as shown in figure 4-7 .
Figure 4-7 Intelligent Analysis
Alarm Configuration
NOTE
Partial camera do not support alarm, this section do not apply.
Alarm input and Alarm output connection:
Step1 Connect alarm input device to Alarm IN0 and Alarm COM0 of multi-
head cable.
Step2 Connect alarm output device to Alarm OUT1 and Alarm COM1 of multi-
head cable, alarm output interface can connect to normal open device only.
Step3 Log in Web, Choose Configuration> Alarm > Alarm output, set the
parameters as shown in figure 4-8.
Step4 Choose Configuration > Alarm > I/O Alarm Linkage , enable the I/O
Alarm and set the parameters of Schedule Setting.
Figure 4-8 Alarm
AI Multi object
At “Configuration > AI Multi object” interface, user can enable face
detection, full body detection, vehicle detection, set the other parameters of
detection.
Figure 4-9 AI Multiobject
Documents / Resources
|
SUNELL SN-IPR8xxxCN Eyeball Network
Camera
[pdf] User Guide
SN-IPR8xxxCN Eyeball Network Camera, SN-IPR8xxxCN, Eyeball Network Camera,
Network Camera, Camera
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>