SUNELL Easy Series Network Camera User Guide

June 9, 2024
SUNELL

Easy Series Network Camera
Quick Setup Guide
NO:101-090-0130-03
Issue:1.3

Precautions

Fully understand this document before using this device, and strictly observe rules in this document when using this device. If you install this device in public places, provide the tip “You have entered the area of electronic surveillance” in an eye-catching place. Failure to correctly use electrical products may cause fire and severe injuries.

WARNING| It alerts you to moderate dangers which, if not avoided, may cause minor or moderate injuries.
---|---
CAUTION| It alerts you to risks. Neglect of these risks may cause device damage, data loss, device performance deterioration, or unpredictable results.
NOTE| It provides additional information.

WARNING

  • Strictly observe installation requirements when installing the device. The manufacturer shall not be held responsible for device damage caused by users’ non- onformance to these requirements.
  • Strictly conform to local electrical safety standards and use power adapters that are marked with the LPS standard when installing and using this device. Otherwise, this device may be damaged.
  • Use accessories delivered with this device. The voltage must meet input voltage requirements for this device.
  •  If this device is installed in places with unsteady voltage, ground this device to discharge high energy such as electrical surges in order to prevent the power supply from burning out.
  • When this device is in use, ensure that no water or any liquid flows into the device. If water or liquid unexpectedly flows into the device, immediately power off the device and disconnect all cables (such as power cables and network cables) from this device.
  • Do not focus strong light (such as lighted bulbs or sunlight) on this device. Otherwise, the service life of the image sensor may be shortened.
  • If this device is installed in places where thunder and lightning frequently occur, ground the device nearby to discharge high energy such as thunder strikes in order to prevent device damage.

CAUTION

  • Avoid heavy loads, intensive shakes, and soaking to prevent damages during transportation and storage. The warranty does not cover any device damage that is caused during secondary packaging and transportation after the original packaging is taken apart.
  • Protect this device from fall-down and intensive strikes, keep the device away from magnetic field interference, and do not install the device in places with shaking surfaces or under shocks.
  • Clean the device with a soft dry cloth. For stubborn dirt, dip the cloth into slight neutral cleanser, gently wipe the dirt with the cloth, and then dry the device.
  • Do not jam the ventilation opening. Follow the installation instructions provided in this document when installing the device.
  • Keep the device away from heat sources such as radiators, electric heaters, or other heat equipment.
  • Keep the device away from moist, dusty, extremely hot or cold places, or places with strong electric radiation.
  • If the device is installed outdoors, take insect- and moisture-proof measures to avoid circuit board corrosion that can affect monitoring.
  • Remove the power plug if the device is idle for a long time.
  • Before unpacking, check whether the fragile sticker is damaged. If the fragile sticker is damaged, contact customer services or sales personnel. The manufacturer shall not be held responsible for any artificial damage of the fragile sticker.

Special Announcement

All complete products sold by the manufacturer are delivered along with nameplates, quick setup guide and accessories after strict inspection. The manufacturer shall not be held responsible for counterfeit products.
The manufacturer will update this manual according to product function enhancement or changes and regularly update the software and hardware described in this manual. Update information will be added to new versions of this manual without prior notice.
This manual may contain misprints, technology information that is not accurate enough, or product function and operation description that is slightly inconsistent with the actual product, the final interpretation of company is as a standard.
This manual is only for reference and does not ensure that the information is totally consistent with the actual product. For consistency, see the actual product.

NOTE
For more information, please refer to website.

Open Package Examination

Open the package, check the appearance of product for no obvious damage, and confirm the item list for table 11 is consistent.
Table 1-1 Packing list

Component Quantity Remark
SE Series Network Camera 1
Quick Setup Guide 1 Optional
Installation location sticker 1
Accessories package 1

Device Ports

NOTE
Different devices may have different multi-head cables;
Please refer to the actual product.SUNELL Easy Series Network Camera - cable
description Table 2-1 Multi-head 1cable description

ID Core Description Remark
1 Network access port Connect to a standard Ethernet cable or PoE. The green

light is on, the network
connection is normal; The yellow light flashes when the data is transmitted.
Some models maybe not have the lights; Please refer to the actual product.| Support PoE
supply.
2| Power supply (DC 12V)| Connect to a 12V direct current (DC) power supply.|
3| Reset button| Long press the reset button for 5s to restore the original settings.|

SUNELL Easy Series Network Camera - Multi-head cable Table 2-2 Multi-head cable 2 description

ID Core Description Remark
1 Network access port Connect to a standard Ethernet cable or PoE. The green

light is on, the network connection is normal; The yellow light flashes when the data is transmitted. Some models maybe not have the lights; Please refer to the actual product.| Support PoE supply.
2| Audio output| Connect to an external audio device such as a speaker.| Applied for camera with audio function
3| Audio input port| Receive an analog audio signal from devices such as a sound pickup device.
4| Reset button| Long press the reset button for 5s to restore the original settings.|
5| Power supply (DC 12V)| Connect to a 12V direct current (DC) power supply.|
6| G| Alarm output COM| Applied for alarmfunction
OUT| Alarm output terminal
G| Alarm input COM
IN| Alarm input terminal

Quick Configuration(e.g IE)

3.1 Login
Step 1 Open the Internet Explorer, input the IP address of IP camera (default value is 192.168.0.123) in the address box, and press Enter. The login page is displayed as shown in figure 3-1.
Step 2 Input the user name and password.

NOTE

  • The default user name is admin. The default password is admin. Change the password when you log into the system for first time to ensure system security.
  • You can change the system display language on the login page.

SUNELL Easy Series Network Camera - LoginStep 3 Click Login icon, the main page is displayed.
3.2 Modify IP address
Choose Setting > Network> IP, the Network page is displayed.
Input the IP address in the IP Address box and click Apply as shown in figure 3-2.
After the IP address is set successfully, please use the new IP address to log in the Web interface.SUNELL Easy Series Network Camera -
Network 3.3 Browsing Video
To ensure the real-time video can be played properly, user must perform the following operation when you login the web at the first time:
Step 1 the Internet Explorer. Choose Tools > Internet options > Security > Trusted sites > Sites, in the display dialog box, click Add, as shown in figure 3-3.SUNELL Easy Series Network Camera - Adding a trusted
siteStep 2 In the Internet Explorer, choose Tool > Internet Options > Security > Customer level, and set Download unsigned ActiveX control and initialize and script ActiveX controls not marked as safe for scripting under ActiveX controls and plug-ins to Enable, as shown in figure 3-4.
Step 3 Download and install the player control as prompted.
NOTE
If the repair tips displayed when installing the control, please ignore the prompt, and continue the installationduring the installation, close the browser. After installation login again to enter the live view.SUNELL Easy
Series Network Camera - Configuring ActiveX controlTo browse a real-time video, click Live View. The Live Video page is displayed, as shown in figure 3-5.SUNELL Easy Series Network Camera -
Live view Description:

  1. User can view the live view.
  2. Playback, if the device install the SD card, user can view playback recording
  3. Click Setting into the setting interface, set the parameter of device.
  4. Click Logout to exit the live view interface, user need to input password to login again.
  5. The alarm, when the alarm action is happening, the icon will show.
  6. and 7 to switch the stream.
  7. Switch the aspect ratio. Double-click in the video area to enter the full-screen mode, and double-click again to exit.
  8. Snapshot, the picture will save to local folder(Setting > Local ).
  9. Record, click this and record the live view and save to local folder.
  10. Click the icon to open the Image Setting page. On the Image Setting page, user can set image, scene, WB, day-night, nosie reduction, enhance image.
  11. Audio, click open or close the audio.
  12. Interphone, click open or close the interphone.

To browse device information, choose ”Setting > System > Information”,the Information page is displayed, as shown in figure 3-6.SUNELL Easy Series
Network Camera - InformationTo set the encode parameters, choose“Setting> Video> Encode”, the “Encode” page is displayed, asshown in figure 3-7.SUNELL Easy Series Network Camera -
Encode

Set the parameters according to the page and click “apply”.

  • If the message “Apply sucess!” is displayed, click OK to confirm. The system saves the settings.
  • If the message “Apply failed!” is displayed, you must apply for the Parameter Configure permission from an administrator.
  • If a message indicating that the “bit rate invalid” is displayed, enter a new bit rate value.

To set alarm information, Choose ”Setting > Alarm >Motion Detection”, the page is displayed, as shown in figure 3-8.

SUNELL Easy Series Network Camera - Motion Detection

Click Enable to enable the motion detection alarm.
Event Actions: User can choose four modes to get the alarm messages.
Area: Drag the mouse left to choose area to set many areas, double-click left button to delete areas.
Schedule: set the time of opening alarm.

  • Click to choose all day and all week.
  • Drag the mouse left button to choose hours.
  • Choose the hours one by one.

Choose “Setting > System >Maintenance” the “Camera Maintenance” is displayed, as shown in figure 3-8. User can reboot ,update and reset the camera in this page.

SUNELL Easy Series Network Camera - Camera Maintenance

  • Click Reboot, the message”Are you sure to restart?” is displayed, then click “OK”, the device is restarted successfully five minutes later.
  • Click Update to update software, choose software and confirm to update.
  • Click Reset, the message “Are you sure to reset?” is displayed, then click “OK”, the device is reset to the factory settings.

CAUTION
After you click reset, all parameters will be restored to the factory settings. Use this function carefully.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SUNELL User Manuals

Related Manuals