NOYAFA NF-466 Cable Tester User Manual

June 9, 2024
NOYAFA

NOYAFA NF-466 Cable Tester User Manual
NOYAFA NF-466 Cable Tester

Warning Icon Please read and learn safety instructions before use or maintain the equipment.

  • This cable tester can’t test any electrified product.
  • 9V reduplicated battery is used in this tester. Battery is a- dvised to change if any weak light appears.
  • Test can’t be done while RJ45’s copper clips are not total-ly pressed. Any disobeys may lead to a permanent damage of the end !
  • Please use quality tools to crimp the cables.
  • Take out the battery if the tester isn’t used for a tong time.

Cable tester

Cable tester

Product Features

  1. It can test corresponding double-twisted cable 1,2,3,4,5, 6,7,8 and G,meanwhile, it can judge wrong connection, short circuit and open circuit.
  2. It can test UTP &STP cable continuity.
  3. It is on standby mode after installing the battery. Quickly get the testing result when insert Cables.

Operating Instructions

After installing the 9V battery, then connect the RJ45 cab-le with Main tester and remotetester, the lights of the ma-in tester will turn on sequentially from 1 to 8;if the cable is STP type, the lights of the main tester will turn on sequ- entially from 1 to Gas bellow: Main tester: 1-2-3-4-5-6-7-8-G Remote tester: 1-2-3-4-5-6-7-8-G

Following are abnormal connections:

  1. If one cable ,for example cable NO.3 is open circuited, the two NO.3 lights of the main tester and remote tester will not turn on.

  2. If several cables are not connected , the corresponding lights will not turn on .11 less than two cables are connec- ted, none of the lights is on.

  3. If two ends of a cable is disordered, for example NO.2 and NO.4, then display as bellow:
    Main tester: 1-2-3-4-5-6-7-8-G
    Remote tester: 1-4-3-2-5-6-7-8-G

  4. If two or more cables are short circuited, the correspond-ing lights won’t be on of the remote tester while main te-ster remains normal.

  5. After operation, turn off the RJ45 cable.
    Operating Instructions

If test patch panels or wall plate outlets, two cables which can match each other.
( Eg 110P4-RJ45 ) will be connected to the tester.