Jandy R0979800 Infinite WaterColors LED Light Controller Instruction Manual

June 13, 2024
Jandy

jandy-logo

Jandy R0979800 Infinite WaterColors LED Light Controller

Jandy-R0979800
-Infinite-WaterColors-LED-Light-Controller-fig- \(4\)Product Information

The Infinite WaterColorsTM LED Light Controller is a device used for controlling and operating LED lights in swimming pools, hot tubs, and spas. It is designed to be used with permanent swimming pools and can also be used with hot tubs and spas if marked accordingly. The controller is compatible with the Jandy Pro spare parts kits: R0979800, R0979900, R0980000, and R0980100. The controller comes with various components, including a Transformer Replacement Kit, PCBA with Bracket, Lid with Foam and  Label, and a pack of Screws (10 packs). These components are necessary for installation and replacement of parts.

Product Usage Instructions

Important Safety Instructions:

  • All electrical work must be performed by a licensed electrician and must comply with national, state, provincial, and local codes.
  • When installing and using electrical equipment, always follow basic safety precautions.
  • Turn off power at the main circuit feeding the power center to disconnect the power center from the system.

Lid Replacement:

  1. Turn off the power to the Light Controller at the breaker panel.
  2. Remove the Light Controller lid screw.
  3. Pull the Light Controller lid up and remove it from DCT.
  4. Slide the new lid on top of the Light Controller, ensuring it is pushed down firmly. Secure the new lid to the Light Controller using the screw.
  5. Turn on the power at the breaker panel.

Transformer Replacement:

  1. Turn off the power to the Light Controller at the breaker panel.
  2. Remove the Light Controller lid screw.
  3. Pull the lid up and remove it from the Light Controller.
  4. Unplug the white transformer input wire connector harness.
  5. Use a 14mm wrench to remove the transformer nut.
  6. Remove the transformer washers and gasket.
  7. Pull the transformer up to gain access to the output wires.
  8. Use a screwdriver to loosen the output wire screws enough to remove the blue transformer output wires.

Note : For detailed visual instructions, refer to the figures provided in the user manual.

These instructions are to be used with the following Jandy Pro spare parts kits:

  • R0979800 Infinite WaterColors Light Controller, Transformer Replacement Kit
  • R0979900 Infinite WaterColors Light Controller, PCBA w/ Bracket
  • R0980000 Infinite WaterColors Light Controller, Lid w/ Foam and Label
  • R0980100 Infinite WaterColors Light Controller, Screws (10 pack)

WARNING

FOR YOUR SAFETY
This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed, where such state or local requirements exist. In the event no such state or local requirement exists, the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation may void the warranty.

Improper installation and/or operation can create unwanted electrical hazards which may cause serious injury, property damage, or death.

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

WARNING: Potentially high voltages in the power center can create dangerous electrical hazards, possibly causing death, serious injury, or property damage. Turn off power at the primary circuit feeding the power center to disconnect the power center from the system.

WARNING: ATTENTION INSTALLER : This manual contains important information about the installation, operation, and safe use of this product. This information should be given to the owner/operator of this equipment.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS
A licensed electrician must perform all electrical work and conform to all national, state, provincial, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

WARNING: Modifications made to this equipment, which are not authorized by the manufacturer, may void the user’s authority to operate this equipment.

Risk of electric shock which can result in serious injury or death: Before attempting to install or service, ensure that all power to the circuit supplying power to the system is disconnected or turned off at the circuit breaker. All wiring must be done by the National Electrical Code® (NEC)®, NFPA-70®, including those in Article 680 – Swimming Pools, Fountains, and Similar Installations.
In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be followed. All applicable local installation codes and regulations must be followed.

WARNING: A terminal bar marked “GROUND” is provided within the power center. To reduce the risk of electrical shock, connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this equipment, but no smaller than no. 12 AWG (3.3 mm2). In addition, a second wire connector should be bonded with a no. 8 AWG (8.4 mm2) copper wire to any metal ladders, water pipes, or other metal within five (5) feet (1.52 m) of the pool/spa. In Canada, the bonding wire must be a minimum of 6 AWG (13,3 mm2).

CAUTION

  • FOR USE ONLY ON A BRANCH CIRCUIT PROTECTED BY A CLASS A TYPE GROUND FAULT CIRCUIT INTERRUPTER.
  • DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL.
  • LANDSCAPE LIGHTING SYSTEMS ARE FOR OUTDOOR USE ONLY.
  • NOT FOR USE IN DWELLING UNITS.
  • DO NOT MOUNT POWER SUPPLY OR LUMINAIRES WITHIN 3 m OF A SWIMMING POOL OR SPA.
  • RISK OF FIRE, DO NOT PLACE INSULATION UNDER THE TERMINAL PLATE.
  • CHECK CONNECTION AFTER INSTALLATION.
  • THE LIGHT LAMP IS HOT!

CAUTION: This device is intended for use with permanent swimming pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.

SAVE THESE INSTRUCTIONS
Verify you have all necessary parts (see Table 1, below.)

KIT PART NO. COMPONENT DESCRIPTION QUANTITY
R0979800 Transformer Replacement Kit 1
R0979900 PCBA with Bracket 1
Screws 2
R0980000 Lid w/ Foam and Label 1x screw
R0980100 Screws (10 pack) 1

Table 1.  Replacement Kit Parts

Lid Replacement

WARNING: To reduce the risk of electric shock, fire, or injury, service should only be attempted by a qualified pool service professional.

Risk of electric shock which can result in serious injury or death: Before attempting to install or service, ensure that all power to the circuit supplying power to the system is disconnected or turned off at the circuit breaker. All wiring must be done by the National Electrical Code® (NEC)®, NFPA-70®, including those in Article 680 – Swimming Pools, Fountains, and Similar Installations.

In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be followed. All applicable local installation codes and regulations must be followed.

LED Light Controller is in acceptable working condition; including all seals/gaskets must be in place and functional; the grounding lug must be present, functional, and bonded; and corrosion must not compromise ingress protection against weather. Additionally, all hardware must be present and functional. If any of the aforementioned conditions are not met, a new enclosure MUST be used.

  1. Turn off the power to the Light Controller at the breaker panel.
  2. Remove the Light Controller lid screw, see Figure 1.
  3. Pull the Light Controller lid up and remove it from DCT, see Figure 1.
  4. Slide the new lid on top of the Light Controller, and ensure the new lid is pushed down firmly.
  5. Secure the new lid to the Light Controller using the screw.
  6. Turn the power on at the breaker panel.

Transformer Replacement

WARNING: To reduce the risk of electric shock, fire, or injury, service should only be attempted by a qualified pool service professional.

Risk of electric shock which can result in serious injury or death: Before attempting to install or service, ensure that all power to the circuit supplying power to the system is disconnected or turned off at the circuit breaker. All wiring must be done by the National Electrical Code® (NEC)®, NFPA-70®, including those in Article 680 – Swimming Pools, Fountains, and Similar Installations.

In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be followed. All applicable local installation codes and regulations must be followed.

LED Light Controller is in acceptable working condition; including all seals/gaskets must be in place and functional; the grounding lug must be present, functional, and bonded; and corrosion must not compromise ingress protection against weather.
Additionally, all hardware must be present and functional. If any of the aforementioned conditions are not met, a new enclosure MUST be used.

  1. Turn off the power to the Light Controller at the breaker panel.
  2. Remove the Light Controller lid screw.
  3. Pull the lid up and remove it from the Light Controller.
  4. Unplug the white transformer input wire connector harness, see Figure 2.
  5. Use a 14mm wrench to remove the transformer nut, see Figure 2.
  6. Remove transformer washers and gasket, see Figure 2Jandy-R0979800-Infinite-WaterColors-LED-Light-Controller-fig- \(2\)
  7. Pull the transformer up to gain access to the output wires, see Figure 3.
  8. Use a screwdriver to loosen the output wire screws enough to remove the blue transformer output wires, see Figure 3.Jandy-R0979800-Infinite-WaterColors-LED-Light-Controller-fig- \(3\)
  9. Remove the old transformer from the Light Controller.
  10. Attach the new transformer blue output wires to output wire screws in Light Controller and tighten.
  11. Plug the new white transformer input wire connector harness into the Light Controller.
  12. Place the new transformer on the Light Controller mounting bolt.
  13. Place the gasket, transformer washers, and transformer nut on the Light Controller mounting bolt and tighten with a 14mm wrench.
  14. Replace the Light Controller lid on the Light Controller.
  15. Replace the Light Controller lid screw and tighten it.
  16. Turn the power on at the breaker panel.

PCBA Replacement

WARNING: To reduce the risk of electric shock, fire, or injury, service should only be attempted by a qualified pool service professional.

Risk of electric shock which can result in serious injury or death: Before attempting to install or service, ensure that all power to the circuit supplying power to the system is disconnected or turned off at the circuit breaker. All wiring must be done by the National Electrical Code® (NEC)®, NFPA-70®, including those in Article 680 – Swimming Pools, Fountains, and Similar Installations.

In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be followed. All applicable local installation codes and regulations must be followed.

LED Light Controller is in acceptable working condition; including all seals/gaskets must be in place and functional; the grounding lug must be present, functional, and bonded; and corrosion must not compromise ingress protection against weather.
Additionally, all hardware must be present and functional. If any of the aforementioned conditions are not met, a new enclosure MUST be used.

  1. Turn off the power to the Light Controller at the breaker panel.
  2. Remove the Light Controller lid screw.
  3. Pull the lid up and remove it from the Light Controller.
  4. Unplug the white transformer input wire connector harness, see Figure 4 (1).
  5. Use a screwdriver to loosen the output wire screws enough to remove the blue transformer output wires, see Figure 4 (2).
  6. Loosen 2 PCBA bracket mounting screws.
  7. Remove the two PCBA lower wire terminals, see Figure 4 (3)
  8. Move the CBA bracket up until the slots clear the PCBA bracket mounting screws, see Figure 4 (4).
  9. Unplug the white lower PCBA connector, see Figure 4 (5).
  10. 10. Remove the old PCBA from the Light Controller, see Figure 4.Jandy-R0979800-Infinite-WaterColors-LED-Light-Controller-fig- \(4\)
  11. Attach the transformer blue output wires to output wire screws on the new PCBA and tighten them.
  12. Plug the white transformer input wire connector harness into the new PCBA.
  13. Plug the lower white PCBA connector into the new PCBA.
  14. Place the new PCBA into the Light Controller with the PCBA bracket slots on the mounting screws and tighten the screws.
  15. Attach the two PCBA lower wire terminals to the right side PCBA mounting screw and tighten.
  16. Replace the Light Controller lid on the Light Controller.
  17. Replace the Light Controller lid screw and tighten
  18. Turn the power on at the breaker panel.

Zodiac Pool Systems LLC 2882 Whiptail Loop #100, Carlsbad, CA 92010 1.800.822.7933 Jandy.com

Zodiac Pool Systems Canada, Inc. 3365 Mainway, Unit 2, Burlington, ON L7M 1A6 1.888.647.4004 Jandy.ca ©2023 Zodiac Pool Systems LLC. All rights reserved. Zodiac® is a registered trademark of Zodiac International, S.A.S.U. used under license. All other trademarks referenced herein are the property of their respective owners.

H0805200 REV A

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>