VENTURE LIGHTING BO0002 LED VSolutions High Bay User Manual
- June 9, 2024
- VENTURE LIGHTING
Table of Contents
VENTURE LIGHTING’S LED VSOLUTIONS HIGHBAY
300W 120-277V, 100W-300W 347-480V
USER MANUAL
BO0002 LED VSolutions High Bay
Before You Begin
Read These Instructions Completely and Carefully
Upgrade Instructions
STEP 1: Disconnect power from the luminaire and follow proper
lockout/tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and
ballast(s) per local requirements.
STEP 3: Each fixture is supplied with a carabiner (1). Place the
carabiner through the eyelet of the eyebolt (2) on top of the fixture.
STEP 4: Attach the carabiner to a secure structure.
STEP 5: Connect the fixture input leads to the supply wire leads.
STEP 6: Each fixture is supplied with 1-10V DC dimming leads.
– If dimming is not needed, nothing needs to be done.
NOTE: Do NOT connect the dimming leads together. This will cause the
fixture to not operate as desired.
– If dimming is desired:
a) Connect the “+” supply lead to the “+” connection lead on the fixture.
b) Connect the “-” supply lead to the “-” connection lead on the fixture.
NOTE: The polarity of the dimming leads is important. Improper connection
will cause the fixture to not operate as desired.
Wiring Diagram
STEP 7: Attach the safety cable carabiner to a secure structure.
STEP 8: Power can now be restored to the fixture.
Reflector Installation
- The reflector is secured to the fixture by the fixture lens trim ring.
- Place the reflector onto the fixture and secure to the fixture with the 3 longer screws supplied with the reflector.
Lens Installation
WARNING
Risk of fire and electric shock
- Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance. Contact a qualified electrician for installation.
- Venture Lighting’s Highbay Fixture installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- Do not make or alter any open holes in a wiring enclosure or electrical component during installation.
- Do not dismantle the fixture without Venture Lighting approval.
- If the external flexible cable of the luminaire is damaged, it should only be replaced by the supplier, a service agent or a Venture Lighting approved qualified person.
CAUTION
- Fixtures are IP65 rated for wet locations.
800-451-2606
6675 Parkland Blvd., Suite 100
Solon, Ohio 44139 USA
E-mail:
Venture_Lighting@VentureLighting.com
VentureLighting.com
© 2022 Venture Lighting International
Venture Lighting is a registered trademark of Venture Lighting International.
http://www.venturelighting.com/
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>