HYTRONIK HBTD8200P Bluetooth Controller with 4 SELV Push Switch Input Instruction Manual
- June 9, 2024
- HYTRONIK
Table of Contents
HYTRONIK HBTD8200P Bluetooth Controller with 4 SELV Push Switch Input
Bluetooth controller with 4 SELV Push Switch Input
Technical Specifications
Download the App
Free App for set-up and commissioning
Web app/platform: www.iot.koolmesh.com
Installation
Warnings:
- Installation must be carried out by a qualified engineer in accordance with local regulations.
- Disconnect power supply before installing.
- Ensure environmental conditions are suitable for electronic equipment
Wire Preparation
To make or release the wire from the terminal, use a screwdriver to push down the button.
- 200 metres (total) max. for 1mm² CSA (Ta = 50℃)
- 300 metres (total) max. for 1.5mm² CSA (Ta = 50℃)
Wiring Diagram
Dimming Interface Operation Notes
Switch-Dim
The provided Switch-Dim interface allows for a simple dimming method using
commercially available non-latching (momentary) wall switches. Detailed Push
switch configurations can be set on Koolmesh app.
Switch Function | Action | Descriptions |
---|
Push switch
| Short press (<1 second)
- Short press has to be longer than 0.1s, or it will be invalid.
| – Turn on/off
– Turn on only
– Turn off only
| – Recall a scene
– Quit manual mode
– Do nothing
Double push
| – Turn on only
– Turn off only
– Recall a scene
| – Quit manual mode
– Do nothing
Long press (≥1 second)
| – Dimming
– Colour tuning
– Do nothing
Sensor-link (VFC signal only)| /| – Upgrade a normal on/off motion sensor
to a Bluetooth controlled motion sensor
Emergency Self-Test Function
| Short press (<1 second)
- Short press has to be longer than 0.1s, or it will be invalid.
| – Start Self test (Monthly)
– Stop Self test
| – Start Self test (Annually)
– Invalid
Long press (≥1 second)
| – Start Self test (Monthly)
– Stop Self test
| – Start Self test (Annually)
– Invalid
Fire Alarm (VFC signal only)
|
Refer to
|
App User Manual V2.1
| – Able to connect the Fire Alarm system
– Once the ire alarm system is triggered, all the luminaries controlled by the Push Switch will enter the preset scene (normally it’s full on), after the ire alarm system gives the ending signal, all the luminaries controlled by this Push Switch will revert back to normal status.
Additional Information / Documents
- To learn more about detailed product features/functions, please refer to www.hytronik.com/download ->knowledge ->Introduction of App Scenes and Product Functions
- Regarding precautions for Bluetooth product installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->Bluetooth Products – Precautions for Product Installation and Operation