HYTRONIK HBTD8200P Bluetooth Controller with 4 SELV Push Switch Input Instruction Manual

June 9, 2024
HYTRONIK

HYTRONIK HBTD8200P Bluetooth Controller with 4 SELV Push Switch Input

HYTRONIK-HBTD8200P-Bluetooth-Controller-with-4-SELV-Push-Switch-Input-
PRODUCT

Bluetooth controller with 4 SELV Push Switch Input

Technical Specifications

HYTRONIK-HBTD8200P-Bluetooth-Controller-with-4-SELV-Push-Switch-Input-
FIG-5

Download the App

Free App for set-up and commissioning

HYTRONIK-HBTD8200P-Bluetooth-Controller-with-4-SELV-Push-Switch-Input-
FIG-1

Web app/platform: www.iot.koolmesh.com

Installation

Warnings:

  1. Installation must be carried out by a qualified engineer in accordance with local regulations.
  2. Disconnect power supply before installing.
  3. Ensure environmental conditions are suitable for electronic equipmentHYTRONIK-HBTD8200P-Bluetooth-Controller-with-4-SELV-Push-Switch-Input-FIG-2

Wire Preparation

To make or release the wire from the terminal, use a screwdriver to push down the button.

  1. 200 metres (total) max. for 1mm² CSA (Ta = 50℃)
  2. 300 metres (total) max. for 1.5mm² CSA (Ta = 50℃)

Wiring Diagram

Dimming Interface Operation Notes

Switch-Dim
The provided Switch-Dim interface allows for a simple dimming method using commercially available non-latching (momentary) wall switches. Detailed Push switch configurations can be set on Koolmesh app.

Switch Function Action Descriptions

Push switch

| Short press (<1 second)

  • Short press has to be longer than 0.1s, or it will be invalid.

| –  Turn on/off

–  Turn on only

–  Turn off only

| –   Recall a scene

–   Quit manual mode

–   Do nothing

Double push

| –  Turn on only

–  Turn off only

–  Recall a scene

| –   Quit manual mode

–   Do nothing

Long press (≥1 second)

| –  Dimming

–  Colour tuning

–  Do nothing

Sensor-link (VFC signal only)| /| – Upgrade a normal on/off motion sensor

to a Bluetooth controlled motion sensor

Emergency Self-Test Function

| Short press (<1 second)

  • Short press has to be longer than 0.1s, or it will be invalid.

| –   Start Self test (Monthly)

–   Stop Self test

| –  Start Self test (Annually)

–  Invalid

Long press (≥1 second)

| –   Start Self test (Monthly)

–   Stop Self test

| –  Start Self test (Annually)

–  Invalid

Fire Alarm (VFC signal only)

|

Refer to

|

App User Manual V2.1

| –   Able to connect the Fire Alarm system

–   Once the ire alarm system is triggered, all the luminaries controlled by the Push Switch will enter the preset scene (normally it’s full on), after the ire alarm system gives the ending signal, all the luminaries controlled by this Push Switch will revert back to normal status.

Additional Information / Documents

  1. To learn more about detailed product features/functions, please refer to www.hytronik.com/download ->knowledge ->Introduction of App Scenes and Product Functions
  2. Regarding precautions for Bluetooth product installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->Bluetooth Products – Precautions for Product Installation and Operation
  3. Data sheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetooth technology ->Bluetooth Sensor ->Receiver Nodes
  4. Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy

www.HYTRONIK.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HYTRONIK User Manuals