Before You Begin

Read These Instructions Completely and Carefully
Upgrade Instructions: Knuckle Mount
STEP 1: Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.
STEP 3: Wrap teflon tape around the knuckle mount nipple (A).
STEP 4: Secure the fixture to 1/2” NPS hole, junction box, or landscape post.
STEP 5: Plug any unsued holes and seal thread with silicone.
STEP 6: Adjust the knuckle to aim the fixture where light is desired. (B)
STEP 7: Connect the fixture input leads (C) to the supply wire leads.

(C) Wiring Diagram – Fixture Without Photocell

(C) Wiring Diagram – Fixture With Photocell

STEP 8: Close the wiring enclosure.
NOTE: Take note NOT to pinch any wires when closing the fixture.
STEP 9: Power can now be restored to the fixture.