VENTURE LIGHTING AV0003 20W Roundback Flood Knuckle Mount Instruction Manual

June 9, 2024
VENTURE LIGHTING

AV0003 20W Runback Flood Knuckle Mount
Instruction Manual

Before You Begin

Read These Instructions Completely and Carefully
Upgrade Instructions: Knuckle Mount
STEP 1: Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.
STEP 3: Wrap teflon tape around the knuckle mount nipple (A).
STEP 4: Secure the fixture to 1/2” NPS hole, junction box, or landscape post.
STEP 5: Plug any unsued holes and seal thread with silicone.
STEP 6: Adjust the knuckle to aim the fixture where light is desired. (B)
STEP 7: Connect the fixture input leads (C) to the supply wire leads.

(C) Wiring Diagram – Fixture Without Photocell

(C) Wiring Diagram – Fixture With Photocell

STEP 8: Close the wiring enclosure.
NOTE: Take note NOT to pinch any wires when closing the fixture.
STEP 9: Power can now be restored to the fixture.

http://www.venturelighting.com/
800-451-2606
6675 Parkland Blvd., Suite 100
Solon, Ohio 44139 USA
E-mail: [email protected]
VentureLighting.com

© 2016 Venture Lighting International • Venture Lighting is a registered trademarks of Venture Lighting International.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VENTURE LIGHTING User Manuals

Related Manuals