VENTURE LIGHTING AV0003 20W Roundback Flood Knuckle Mount Instruction Manual
- June 9, 2024
- VENTURE LIGHTING
Table of Contents
AV0003 20W Runback Flood Knuckle Mount
Instruction Manual
Before You Begin
Read These Instructions Completely and Carefully
Upgrade Instructions: Knuckle Mount
STEP 1: Disconnect power from the luminaire and follow proper lockout/tagout
procedures before beginning installation or maintenance.
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s)
per local requirements.
STEP 3: Wrap teflon tape around the knuckle mount nipple (A).
STEP 4: Secure the fixture to 1/2” NPS hole, junction box, or landscape post.
STEP 5: Plug any unsued holes and seal thread with silicone.
STEP 6: Adjust the knuckle to aim the fixture where light is desired. (B)
STEP 7: Connect the fixture input leads (C) to the supply wire leads.
(C) Wiring Diagram – Fixture Without Photocell
(C) Wiring Diagram – Fixture With Photocell
STEP 8: Close the wiring enclosure.
NOTE: Take note NOT to pinch any wires when closing the fixture.
STEP 9: Power can now be restored to the fixture.