PHILIPS RC332V SlimBlend Gen2 Ceiling Light
Product info
583 – 444316027081
2023-01
Signify Holding
All rights reserved
Printed in Hungary
Data subject to change without notice
Keep for future reference:
www.philips.com/lighting
VPC visible profile ceiling| CPC Concealed profile ceiling| PCV
plaster ceiling| SP suspended
---|---|---|---
SM surface mounted|
Available as accessory (Need to purchase separately)
Suspension set (Not for EL):| Surface mounted kit (Not for EL):
911401879384 RC330Z SME-3 WH (For SEIA/WIA)|
911401878984 RC330Z SMB W60L60
911401879484 RC330Z SME-4 WH (For PSD/DEIA)|
911401879084 RC332Z SMB W62L62
| 911401879184 RC330Z SMB W30L120
|
Recessed mounting –
Mounting clips for plastered ceilings
911401879284 – RC330Z SMB-PLC| Recessed mounting –
Mounting brackets for ceiling systems with concealed profile 910505102499
RC330Z SMB-CPC
| Versions with Quick Connector (integrated Push In Connector with Pull
relief)
PSD/DEIA/WIA/SEIA
|
Through wiring is not possible, but the quick connector allows loop through
wiring
WIA EL / SEIA EL
-
Connector 1
-
Connector 2 (for EL)
UnN – Unswichted N
UnL – Unswichted L
PSD EL / DEIA EL
Versions with Wieland connector (W3, W3W2, W4, W4W2, W5)
If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent
VPC – Visible Profile Ceiling/ Lay-in mounting
Safety cable (SC)
PCV -Recessed mounting in plastered ceilings (911401879284 – RC330Z SMB-PLC)
| A (mm)| B (mm)
---|---|---
W60L60| 580| 580
W30L120| 1180| 280
W62L62| 605| 605
CPC – Recessed mounting in Concealed profile ceilings – Brackets have to be ordered separately
- Replace the original screws
26-76 mm position
26-76 mm position
26-76 mm position
26-76 mm position
26-76 mm position
26-76 mm position
sym-concealed
A-sym-concealed
26-76 mm position
Surface mounted (Not for WIA version and not for battery emergency versions;
for DC emergency versions usable)
911401878984 – RC330Z SMB W60L60, 911401879084 – RC330Z SMB W62L62,
911401879184 – RC330Z SMB W30L120
| A (mm)| B (mm)| C (mm)| D (mm)
---|---|---|---|---
W60L60| 612| 612| 332| 576,5
W62L62| 637| 637| 327| 601,5
W30L120| 1212| 312| 623| 276,5
Suspension set (Not for EL versions):
SEIA/WIA
911401879384 – RC330Z SME-3 WH
PSD/DEIA
911401879484 – RC330Z SME-4 WH
Indicator LED
The indicator LED must be mounted into the ceiling, close to the luminaire
Emergency luminaires with battery (ELD3, ELP3, ELW3)
In case a self-contained driver has been added, this is how to set the timers
(IEC62034 (6.3.2.)):
- Dali version (ELD3): Check IEC 62369 part 202,
- PRO version (ELP3): The first test is randomized. Then a fixed schedule is maintained there is no need to set the timers or take special precautions when powering,
- Sensor version (ELW3): ELW types are shipped with Emergency Inhibit Mode on. To enable normal emergency operation, commissioning is needed through Interact Enterprise.
ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES
-
The luminaire shall be installed by qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
-
The light source contained in this luminaire is non user replicable, it shall only be replaced by the manufacturer or his service agent or a similar qualified person
-
During the installation or maintaining the luminaire please use gloves to avoid spots on the cover.
To remove dirt and spots use the following: -
Dust: use micro fiber cloths only.
-
Fingerprints, etc.: use cleaner for synthetic materials with antistatic properties.
-
Luminaires not suitable for covering with thermally insulating material.
-
For controllable luminaires, the classification of the insulation between LV supply and control conductors shall be basic insulation at least.
-
Luminaires must not be used or stored in corrosive environment where hazardous materials such as Sulphur, Chlorine, Phthalates, etc., are present.
Battery Unit (LFP)
Manufacturer:| Philips
Unit:| Trust Sight 3.2V 3cell
4500mAh battery LFP
Technology:| Lithium-ion
Luminous flux:| 270 lm
Capacity:| 4500 mAh
Power:| 2 W
Duration:| 3H
Nominal voltage:| 3.2 V
Battery Unit (NiMH)
Manufacturer:| Philips
Unit:| Trust Sight 3.6V 3cell
4000mAh battery NiMH
Technology:| Nickel metal hydride
Luminous flux:| 270 lm
Capacity:| 4000 mAh
Power:| 3 W
Duration:| 3H
Nominal voltage:| 3.6 V
The default battery type is LFP, In view of scarcity also NiMH ascus might be
used.
Please check luminaire before ordering spare batteries.
Polar diagrams for EL versions
-
W60L60 MXO
Rated luminous flux in emergency operation mode: 270 lm
-
W60L60 OC
Rated luminous flux in emergency operation mode: 270 lm
-
W62L62 MXO
Rated luminous flux in emergency operation mode: 270 lm
-
W30L120 OC
Rated luminous flux in emergency operation mode: 270 lm
-
W30L120 MXO
Rated luminous flux in emergency operation mode: 270 lm
DEIA, SEIA versions: The luminaire is working on 15% of the rated luminous flux by DC supply
DC: 186-240V
Charge time
Lifetime
The batteries have a life time expectancy of 4 years when maintained properly.
Replace after that time!
Automatic emergency time selection
After installation and power up the driver will detect the battery and start
the automatic detection process.
- During automatic detection, the indicator LED will light up with short green flashes.
- Between minimum 6 and maximum 30 seconds the Trust Sight driver will set the battery type (number of ce and will set the emergency output power accordingly.
After that, the system is defined and fully operational. The battery type definition has influence on the performance during the self-test and on the battery charge method. When the automatic battery detection process is disrupted, e.g. by switching off the permanent mains, the detection process is stopped and the TrustSight emergency driver will go into emergency mode with the lowest output power. At a next power up, the automatic detection process will start again.
Periodic testing
Periodic tests of emergency lighting luminaires must be performed according to
ENS0172 clause 7.23 and 7 2.4. Switch on in the emergency mode each month by
simulation of a failure of the supply to the normal lighting •or a period
sufficient to ensure that each lamp is illuminated. Twice per year, each
luminaire shall be tested for its full rated duration (at least 3hrs).
For more information please consult the Trust Sight Gen 3 Design m guide. The
latest version is available online.
LED indicator status
PSD/DEIA | WIA | SEIA | |
---|---|---|---|
Electrical characteristics | |||
Imax (A) | 5,5 | 4,8 | 9 |
Tred (µs) | 55 | 56 | 25 |
MCB | No. of luminaires max. | ||
B-10 A | 21 | 32 | 21 |
B-16 A | 32 | 50 | 32 |
C-10 A | 32 | 52 | 32 |
C-16 A | 55 | 85 | 55 |
To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and ios).
SR compatibility –
For SR-based luminaires only SR-Certified components/sensors are to be used
(see also: http://www.lighting.philips.co.uk/oem-emea/products/driving-
connected-lighting).
The functional compatibility of two (SR-certified) components/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based luminaire, is to be released by the master component/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non-compliance for which Signify cannot take any responsibility.
Disconnect before servicing
Luminaire has basic insulation between Low Voltage supply and control
conductors.
The light source and/or control gear and/or the external flexible cable
contained in this luminaire shall only be replaced by the manufacturer or
his service agent or a similar qualified person.
Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
This product contains a light source of energy efficiency class: see table or label.
Zhaga-D4i and SR certified compatibility – For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products / https://www.lighting.philips.co.uk/oem-emea/products/driving-connected- lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-D4i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non- compliance for which Signify cannot take any responsibility.
© 2023 Signify Holding
All rights reserved. This document contains information relating to the
product portfolio of Signify which information may be subject to change. No
representation or warranty as to the accuracy or completeness of the
information included herein is given and any liability for any action in
reliance thereon is disclaimed. The information presented in this document is
not intended as any commercial offer and does not form part of any quotation
or contract. Philips and the Philips Shield Emblem are registered trademarks
of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding
or their respective owners.
Signify Holding
The Netherlands
References
- OEM Lighting - Connected with Quality | Philips lighting
- Driving connected lighting | Philips lighting
- Sustainable LED lighting solutions | Philips lighting
- Sustainable LED lighting solutions | Philips lighting
- Sustainable LED lighting solutions | Philips lighting
- Driving connected lighting | Philips lighting
- Products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>