AKO-52044 iOS-Android App User Manual
- June 9, 2024
- AKO
Table of Contents
52044 iOS-Android App
User Manual
AKO-52044 iOS-Android App
-
**** Use of the application “AKO-52044” involves the sending of SMS messages by both the alarm and the user of the application. Please check the cost of this service with your operator.
-
The application does not save the data sent to the alarm, or the phone numbers on the list, or the configuration of the digital inputs, or any other information.
The information is ONLY stored in the alarm. -
To see the phone list, the configuration of the inputs of the alarm centre, or other queries, go to the “QUERY” section and select the required query.
Download the Application
To download the application, search for “AKO-52044”, from the Play Store on Android or from the App Store in iOS (iPhone) and select “Install”.
Add the alarm in the application as a contact
The phone number used by the alarm must be saved in the application so that it
can communicate with it, this alarm is also stored in the memory of the mobile
phone as a new contact.
If this number is already on the contacts of the mobile, press the following
icon/blank space: If, on the other hand, it is a new number, press “+” and
follow the steps to create a new contact.
Once created, the contact is displayed in the application next to the “+”
icon.
Telephone list configuration
Select the menu option CONFIGURATION/ telephone list configuration.
Fill in the following fields:
Password: Enter the password of the unit, 1234 by default.
Time to respond: Indicate the maximum time in minutes to respond to an
alarm. If after this time has elapsed no confirmation is received, the alarm
is sent to the next number on the list.
Telephone numbers: The telephone numbers to which alerts detected are
sent by order of priority.
Supports international prefixes (for example, +34 for Spain).
IMPORTANT: The telephone number must be saved as received in the alarm
(prefixes included), if you have any questions, run “See my phone number”
explained on page 13.
When the fields have been filled in, press:
After a few moments, the alarm responds*:
Only telephone numbers saved on that list can make changes to the
configuration.
Digital input configuration
Select the menu option, CONFIGURATION/Digital input configuration
Fill in the following fields:
Input Number: Indicate the
number of digital input to be configured
Normally closed NC/Normally open NO: Select the status of the entry NO
ALARM
Alarm trigger delay time: Indicate the turn-on delay time for the alarm,
this delay determines how low the input must remain active before the alarm is
triggered.
Android: Time expressed in minutes (max. 108).
iOS: Time expressed in seconds (max. 6500).
Alarm message to send: Indicate the alarm message to be sent in the event
of an alarm. No accents, umlauts or special characters may be used (max. 100
characters).
When the fields have been filled in, press:
After a few seconds, the alarm responds with the message: x:
Corresponding input number
If the “Error 2″ or “Not authorised” message is received, refer to page 13.
Working on battery power message customization
Select the menu option, ADVANCED CONFIGURATION/Working on battery power
message customization
Indicate the messages to send in the event of a power failure or restoration
of power. No accents, umlauts or special characters may be used.
When the fields have been filled in, press:
After a few seconds, the alarm responds with the message*:
*If the “Error 2″ or “Not authorised” message is received, refer to page 13.
Change of Time and Date
Select the menu option, ADVANCED CONFIGURATION/Time change
The alarm is shipped from the factory with the date set as 01/01/00 and the
time set to 00:00:00. You must set the correct time and date so that event
queries (LOG) are correct.
Indicate the current time and date.
When the fields have been filled in, press:
After a few seconds, the alarm responds with the message*:
See status of the equipment
Select the menu option, QUERY/See status of the equipment and press .
After a few moments, the alarm responds with*:
*If the “Error 2″ or “Not authorised” message is received, refer to page 13.
Activate/Deactivate output relays
Select the menu option, ACTIVATE/ Output relay activation.
Set the value of the output relays as you wish and press:
Message “Error 2” or “Not authorised”
If, during configuration you receive the answer “Error 2” or “Not authorised”,
the telephone number used may
not be saved in the phone list precisely as the alarm expected to receive it.
To verify this, go to QUERY/See my
phone number and press .
After a few moments, the alarm sends a response similar to this one*:
The number returned by the alarm is precisely the number that must be stored
in the telephone list of the alarm (prefix included).
Go to QUERY/See telephone list and press .
After a few moments, the alarm responds with a message similar to this one*:
Check that the number you have just received coincides exactly with the one in the list, if not change it typing exactly the number received (prefix included). See page 9.
AKO ELECTROMECÁNICA , S.A.L.
Avda. Roquetes, 30-38
08812 • Sant Pere de Ribes.
Barcelona • Spain.
www.ako.com
We reserve the right to supply materials that might vary slightly to those described in our Technical Sheets. Updated information is available on our website.
355204421 Rev 03 2023
Documents / Resources
| AKO
AKO-52044 iOS-Android
App
[pdf] User Manual
AKO-52044 iOS-Android App, AKO-52044, iOS-Android App, Android App, App
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>