BluMill OL-BKY26-A011F Portable Air Conditioner Plus WiFi Instruction Manual

June 4, 2024
bluMill

BluMill OL-BKY26-A011F Portable Air Conditioner Plus WiFi

BluMill OL-BKY26-A011F Portable Air Conditioner Plus WiFi
product

Our powerful portable air conditioners are great cooling solutions for single rooms, creating a comfortable atmosphere in your space. It also has ventilation and dehumidifying function for circulating air and removal of moisture. They’re self-contained systems that do not require any permanent installation allowing you to move to the space in which it is most needed. They’re commonly used in kitchen, temporary resided, computer rooms, garages, and many other places where installation of Air-conditioner Outdoor Unit is limited. The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Because of its efficient energy properties, R290 is highly suitable as a coolant for this application. Special precautions must be taken into consideration due to the coolant’s high flammability.

THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • The unit is designed only for use with R-290 propane gas as the designated refrigerant.
  • The refrigerant loop is sealed.
  • Only a qualified technician should attempt to service!
  • Do not discharge the refrigerant into the atmosphere.
  • R-290 (propane) is flammable and heavier than air.
  • It collects first in low areas but can be circulated by the fans.
  • If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.
  • The propane gas used in the unit has no odor.
  • The lack of smell does not indicate a lack of escaped gas.
  • If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact the local fire department to advise them that a propane leak has occurred.
  • Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the room.
  • No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.

OPERATIONAL PRECAUTIONS
WARNING
To reduce the risk of fire, electric shock or injury to persons or property

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The appliance shall be disconnected from its power source during service.
  • Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate with wet hands. Prevent water from spilling onto the unit.
  • Do not immerse or expose the unit to rain, moisture or any other liquid.o not leave the unit running unattended. Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not unplug by pulling on the power cord.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminum fins of the unit.
  • Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive.

WARNING
Install the unit in rooms which exceed 10 m². Do not install the unit in a place where inflammable gas may leak. Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by a national accredited organization that ensures competence in handling flammable refrigerants according to a specific evaluation recognized by national associations in the industry and compliant with the latest R290 guidance.

PRODUCT DIAGRAM

  1. Control panel
  2. Air inlet with air filter
  3. Drainage Hole
  4. Air outlet with adjustable louver
  5. Caster
  6. Air Exhaust
  7. Handle

Note
The appearance is only for reference. Please see the real product for detailed information.

FEATURES

  • High Capacity in a compact size with cooling, dehumidifying and fan function.
  • Temperature setting and display
  • LED Digital display
  • Electronic control with built-in timer, sleep mode
  • Self-evaporating system for better efficient
  • Auto shut off when tank full
  • Automatic restart in the event of power outage
  • Auto defrosting function at low ambient temperatures
  • Remote control
  • 2- speed fan
  • Casters for easy mobility

UNPACKING

  • Unpack the carton and take the appliance and accessories out.
  • Check the device after unpacking for any damage or scratches on it.
Accessories

BluMill OL-BKY26-A011F Portable Air Conditioner Plus WiFi
7

  1. Exhaust hose
  2. Hose connector
  3. Window kit adapter
  4. Remote control
  5. Window kit

Choose your location

  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
  • Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
  • Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet.
  • Keep the air inlet and outlet free of obstacles.
  • Never install the unit where it could be subject.
  • Heat sources such as radiators, heat registers, stoves or other products that products that produce heat.
  • Direct sunlight.
  • Mechanical vibration or shock.
  • Excessive dust.
  • Lack of ventilation, such as cabinet or bookcase.
  • Uneven surface.

WARNING
Install the unit in rooms which exceed 10 m². Do not install the unit in a place where inflammable gas may leak.

ATTACH THE EXHAUST HOSE

The air conditioner requires being vented outside so that the exhaust air can escape the room which coming from the appliance contains waste heat and moisture. Do not replace or extend exhaust hose which will result in decreased efficiency, even worse shut down the unit due to low backpressure.

Step 1

Connect the hose connector to one end of the exhaust hose.

Step 2

Connect the windows kit adapter to the other end of the exhaust hose.

Step 3

Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit.

Step 4

Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.

Step 5

Attach the hose connector to the exhaust air outlet of unit.

Step 6

Adjusting the length of the flexible exhaust hose, and avoid bends in the hose. Then place AC near an electrical outlet.

Step 7

Adjust the louver at the air outlet, and then switch on the unit.

OPERATION CONTROL PANEL

BluMill OL-BKY26-A011F Portable Air Conditioner Plus WiFi
8

1| POWER| | Press to switch the machine on or off.|
---|---|---|---|---
|
2| MODE| | Press to switch the operation mode between fan,|
| cooling and dehumidifier.|
3| SPEED| | Press to switch the fan speed between HIGH and|
| LOW|
4| DOWN| | Decreasing the desired temperature or timer|
| setting.|
5| UP| Increasing the desired temperature(16ºC~32ºC) or|
timer setting.|
6| TIMER| | Sets a time for the unit to automatically start or|
| stop.|
7| SLEEP| | Press to turn on sleep mode or off.|
|
8| LOCK| | Press to turn on or turn off the child lock function|
|

DISPLAY

  1. High Fan Speed
  2. Low Fan Speed
  3. Timer
  4. Dehumidifier Mode
  5. Cooling Mode
  6. Fan Mode
  7. Sleep
  8. Lock
  9. Display Window

REMOTE CONTROL

BluMill OL-BKY26-A011F Portable Air Conditioner Plus WiFi
10

SETTINGS

Start up and Shutdown
  • Press POWER to turn the unit on.
  • The unit runs in in FAN as default.
  • Press MODE button to select the desired operation mode.
  • Press POWER again to turn off the power.
Operation mode

The unit has four operation modes: Cool, dry, fan, sleep.

Cooling your room
  • Select the cool mode to lower the temperature in your room.
  • Press MODE button repeatedly until the LED of COOL operation lights up.
  • Press Up/Down button to adjust the temperature which is displayed on the screen.
  • The temperature can be set between 16ºC and 32ºC.
  • Press SPEED button repeatedly until the desired fan speed indicator lights up.
  • To control the direction of the air flow horizontally, please adjust the inner louver by hand.

Note
The air conditioner stops if the room temperature is lower than selected temperature.

Ventilating your room
  • Press MODE button repeatedly until the LED of FAN operation lights up.
  • In ventilation mode the room air is circulated, but not cooled.
  • Press SPEED button repeatedly to select the fan speed as desired.
Drying your room

Press MODE button on the control panel or remote control, the LED of DRY operation lights up. The fan speed is unable to select. User should connect the hose to the drain outlet at the bottom of the unit.

Note
In this mode, the fan speed switches over to low speed and cannot be selected.

Sleep mode

This function can only be used with a remote control. The sleep mode can be activated when in cool mode and heat mode.

In cool mode

After 1 hour the preset temperature is increased by 1 ℃, after another hour the preset temperature will again be increased by 1ºC.

TIMER SETTING (1hour-24hours)

The timer has two ways of operation

To turn off When power on

Press Timer key to turn on the timer function. Press Up/Down repeatedly to set the delay OFF time.

To turn on When power off

Press Timer key to turn on the timer function. Press Up/Down repeatedly to set the delay ON time.

Cancel timer

Press Up/Down repeatedly until the LED shows ‘00’. Note: when press POWER will also exit the timer setting.

Automatic Defrost

At low room temperatures, frost may buildup at the evaporator during operation. The unit will automatically start defrosting and the POWER LED blinking. The defrost control sequence is as follows

  • When the unit operates in the cooling operation, drying operation, the ambient temperature sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop operating for 10 minutes or the coil temperature up to 7℃, the unit restart to cool operating mode.
  • When the unit operates in the drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 40℃ and the differential tempera-ture between coil temperature and room temperature is below 19℃ after the compres-sor operation for 20minutes, the unit start defrosting for 5 minutes and the power indicator blinking.

Overload Protection

In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.

DRAINAGE

Self evaporating system

The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance. It is no need to empty the drainage tank in cooling operation except in drying operation and high humidity conditions. The condensate water evapo-rates at the condenser and evacuated through the exhaust hose. For continuous operation or unattended operating in drying and heating operation, please connect the attached drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity.

  • Switch off the unit before operating.
  • Remove the plug of the water outlet opening, and keep it in safe area.
  • Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
  • Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
  • Do not submerge the end of hose into water; otherwise it can cause Air Lock in the hose.
To avoid water spillage

As the negative pressure of condensate drain pan is large, tilt the drain hose down-ward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees. Straighten the hose to avoid a trap existing in the hose.

CLEANING AND CARE

CLEANING THE AIR FILTER every two weeks

Dust collects on the filter and restricts the airflow. The restricted airflow reduces the effici-ency of the system and if it becomes blocked it can cause damage to the unit. The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Press POWER button to switch off the unit and unplug the power cord.
  2. Remove the filter mesh from the unit.
  3. Use a vacuum cleaner to suck dust from the filter.
  4. Turn the filter over and rinse the air filter under running water.
  5. Let the water run through the filter in the opposite direction of air flow.
  6. Set aside and allow the filter to air dry completely before reinstalling.
Switch off the unit and remove the two air filters
Rinse the air filter under running water

CLEANING UP OF REFRIGERANT

General Measures
  1. Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or below ground level.
  2. Eliminate every possible source of ignition.
  3. Use appropriate personal protection equipment (PPE).
  4. Evacuate unnecessary personnel, isolate, and ventilate area.
  5. Do not get in eyes, on skin, or on clothing.
  6. Do not breathe vapors or gas.
  7. Prevent entry to sewers and public waters.
  8. Stop the source of the release, if safe to do so.
  9. Consider the use of water spray to disperse vapors.
  10. Isolate the area until gas has dispersed.
  11. Ventilate and gas test area before entering.
  12. Contact competent authorities after a spill.

TROUBLESHOOTING

Symptom Inspection Solution
The unit is not operating. Check the power connection in securely. Insert

the power cord securely into the wallOutlet.
Check if the water level indicator lights up?| Empty the drain pan by remove the rubber plug.
Check the room temperature.| The range of operating temperature is 5-35ºC.
The unit works with reduced capacity.| Check the air filter for dirt.| Clean the air filter as necessary.
Check if the air duct is blocked.| To clear the obstacle.
Check if the room door or window is open.| Keep the door and windows closed.
Check if the desired operating mode is selected and the temperature is properly set.| Set the mode and temperature at proper set-point according the manual.
The exhaust hose is detached.| Make sure the exhaust hose is securely attached.
Water Leakage| Overflow while moving the unit.| Empty the water tank before transport.
Check if the drain hose is kinked or bends.| Straighten the hose to avoid a trap existing.
Excessive Noise| Check if the unit is securely positioned.| Place the unit on horizontal and firm ground.
Check if any loose, vibrating parts.| Secure and tight the parts.
Noise sounds like water flowing.| Noise comes from flowing refrigerant. This is normal.
Symptom| Inspection| Solution
---|---|---
Error Codes| E0| Communication faults between main PCB and display PCB.| Check the wire harness of the display PCB for damage.
E1| Ambient temperature sensor failure| Check connection or re- place it. To clean or replace the temperature sensor.
E2| Coil temperature sensor failures.| Check connection or re- place it. To clean or replace the temperature sensor.
Ft| Condensate water high level alarm.| Empty the drain pan by removal the rubber plug.

DECOMMISSIONING

STORAGE

Long-Term Storage – If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following steps

  1. Unplug the unit and remove exhaust hose and window kit store with the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Re install the filter at its position.
  5. The unit must be kept in upright position when in storage.
  6. Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.

ATTENTION
The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.

WARNING
Releasing refrigerant into atmosphere is strictly forbidden.

WIFI COPERATION

Information on the App Smart Life

The Smart Life app is available for android and iOS. Scan the corresponding QR code to get directly to the download.

Information on How to Use the App

This appliance allows you to operate the appliance via your home net work. A prerequisite is a permanent WIFI connection to your router and the free app Smart Life. We recommend disconnecting the appliance from the power supply when you are away from home to prevent unintentional switching on while you are on the road!

Commissioning via the App

  1. Install the Smart Life app.
  2. Create a user account.
  3. Activate the WIFI function in the settings of your appliance.
  4. Place the appliance at a distance of about 5 meters to your router.
  5. As long as the power is turned on, the WIFI indicator flashes slowly.
  6. After 3 minutes, the status will be canceled if there is no network configuration, and the indicator light is off.
  7. If you need to re-connect the WIFI, long press the timer button for 5 Second to start the network configuration, the WIFI indicator flashes slowly.
  8. When WIFI indicator flashes slowly, select Add Device Large Home Appliances Air Conditioner and follow the instructions on the display.
  9. Select AP Mode on upper right of the app, choose Confirm indicator slowly blink and press Go to Connect” to connect the WIFI named SmartLife-XXXX.
  10. Once the appliance has been successfully connected, the WIFI lamp lights up. Now you can operate the appliance using the app.
  11. Press and hold the Timer button for about 5 seconds, the appliance disconnect, the WIFI lamp lights off.
Network connection failed Solution
Network connection timeout Check if you select the WIFI named SmartLife XXXX

Turn off the machine and unplug the power code and plug in after 10 seconds, enter the App to connect again.

WIFI indicator off| Long press the Timer button or Turn off the machine and unplug the power code and plug in after 10 seconds.
WIFI hotspot disappear and the WIFI light flash| Turn off the machine and unplug the power code and plug in after 10 seconds, enter the App to connect again.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well being.