CERBERUS PYROTRONICS Conventional Fire Alarm Systems Owner’s Manual

June 9, 2024
CERBERUS PYROTRONICS

CERBERUS PYROTRONICS Conventional Fire Alarm Systems

Fire Alarm Control

PXL Fire Alarm Control
  • 12 Zones Expandable to 32
  • 10 Amp Power Supply Expandable to 20
  • 4 Notification Appliance Circuits Expandable to 16
  • 2 Amps per Notification Appliance Circuit

Order Model PXL, Part No. 599-694189

  • Features Easy to Use, ATM-Style Display for Operating & Programming
Fire Alarm Control Panels

All of Cerberus Pyrotronic’s conventional Fire Alarm Controls are listed/approved by UL, ULC, CSFM & NYMEA. These microprocessor-based panels are listed as compatible with all of the accessories included here. They also include software-based features to meet any need including supervisory monitoring, waterflow alarms, event history logs, and zone bypass. They provide a complete system solution for any zoned building.

SXL Fire Alarm Control
  • 4 Zones Expandable to 8
  • 3 Amp Power Supply
  • 2 Notification Appliances Circuits
  • Field Programmable Software Features for Every Application

PE-11 Self-Diagnostic Detector

  • Advanced Field Cleanable Chamber Design
  • UL Listed Self-Test Feature
  • Multi-Color LED for Normal, Trouble, or Alarm Indication
  • Low-Profile Design
  • Easy Twist-In Base Design
  • Made in USA at ISO 9001 Facility
  • Listed, ULC Listed, FM, CSFM, NYMEA Approved
    • Order Detector Model PE-11, Part No. 500-094150
    • Order Base Model DB-11, Part No. 500-094151

Smoke Detectors

Cerberus Pyrotronics smoke detectors have been developed using an extensive history of fire test data. This experience is designed into new technology products that provide high reliability while reducing installation costs and test time.

The DI-3 has standardized the ionization detection principle for over 15 years. PE-11 uses a self-test feature to eliminate the need for special sensitivity meters. The PBA-1191 contains both transmitter and receiver in one housing to reduce installed wiring costs. These devices satisfy any smoke detection problem.

DI-3 Ionization Smoke Detector

  • Adjustable Sensitivity
  • Dual Chamber
  • Sensitivity Test Points
  • Simple Twist/Lock Assembly
  • Optional Auxiliary Relay
  • Screw-Clamp Terminals
  • Alarm LED
  • Listed, ULC Listed, FM, CSFM, NYMEA Approved
    • Order Detector Model DI-3, Part No. 500-081806
    • Order Base Model DB-3S, Part No. 595-381804
Linear Beam Smoke Detector
  • Transmitter and Receiver are Installed in the Same Housing
  • Easy Alignment and Installation
  • Two-Wire Installation
  • Suitable for Ranges from 17 Feet to 280 Feet
  • Response Behavior Selectable in Three Sensitivity Settings
  • High Immunity to Extraneous Light
  • Automatic and Comprehensive Self-Test
  • Operates According to the Principle of Light-Attenuation by Smoke
    • Order Detector Model PBA-1191, Part No. 500-095076
    • Order Base Model PBB-1191, Part No. 500-095077
    • Order Reflector Model PBR-1191, Part No. 500-095078

VoiceCom Voice/Alarm Communication System

  • 25 or 70.7 VRMS Audio (Field Selected)
  • True 100 Watts RMS Output Capacity
  • Up to 11 Optional Speaker and Strobe Circuit Modules in One Cabinet
  • All Outputs are Power Limited & Supervised
  • Style Y (Class B) and Style Z (Class A) Speaker and Strobe Circuits
  • Dry Contact or polarity reversal Activation
  • Activation Inputs are Fully Supervised
  • Optional Digital MessageMaker is Field Programmable
  • Coded Tone Option
  • Backup Evacuation Tone Option
  • Stand Alone or for Use with any Fire Alarm/Suppression Control Panel
  • Listed, ULC Listed, CSFM, NYMEA Approved
    • Order Model VoiceCom, Part No. 500-693713 (50 Watts)
    • Order Model VoiceCom-MM, Part No. 500-693714 (50 Watts with MessageMaker)
    • Order Model VoiceCom-L, Part No. 500-694227 (100 Watts)

PAD-2 Auxiliary Power Supply / NAC Extender

  • 6 Amps of Notification Appliance Power
  • Advanced Microprocessor Control
  • 24 VDC Regulated Output Voltage
  • Four Power-Limited Notification Outputs
  • Synchronized ANSI Temporal Pattern
  • Class ‘A’ Selectable
  • Ground Fault Detection
  • Battery Supervision
  • 3 Amp Auxiliary Power Output
  • Trouble Contact for Monitoring
  • Listed
    • Order Model PAD-2, Part No. 500-694275

Building Evacuation
The Americans with Disabilities Act has driven the need for notification capacity in all buildings. VoiceCom Emergency Voice/Alarm Evacuation System and the PAD-2 NAC Extender provide for the control of notification appliances throughout any structure. Both products can be configured in multiple ways to meet local codes for installation as well as for safe building evacuation.

F-Series Notification Appliances

  • S-Strobes 15, 15/75, 75 & 110 Candela Models
  • SS-Strobes-Synchronized
  • MTL – 8 Tone Electronic Horns
  • MTLS – 8 Tone Horn Strobes
  • E – Single Tone Horns
  • ES – Single Tone Horn Strobes
  • HN – Electro-Mechanical Horn
  • HNS – Electro-Mechanical Horn-Strobes
  • SM – Speakers ¼ to 2 Watt and Speaker Strobes
  • SH – High Output Speakers 1/3 to 2½ Watts and Speaker Strobes
  • Meet the Americans with Disabilities Act
  • Meet UL 1971CERBERUS-PYROTRONICS-Conventional-Fire-Alarm-Systems-fig- \(9\)

Notification Appliances
Cerberus Pyrotronics F-Series Notification Appliances will satisfy the requirements of ADA and UL 1971 and are UL, ULC Listed compatible with our systems. Additionally, they provide for a range of tones, audibility levels, strobe power and synchronization of strobes to meet the needs of all types of building occupancy. F-Series devices also feature low power consumption to minimize system demand and low in-rush duration to improve system reliability.

How to Read F-Series Signal Model Numbers
Most F-Series products follow a simple pattern as follows: the first series of letters/numbers describe the base signal class, the second set describe the strobe if applicable, the third set describes the mounting configuration. Please refer to the specific catalog sheet for each base signal class.

CERBERUS-PYROTRONICS-Conventional-Fire-Alarm-Systems-fig-
\(10\)

LED Series Remote Annunciators

  • 8 or 16-Zone LED Display
  • Annunciates Zone Alarms, Supervisory and Trouble Conditions
  • Surface or Semi-Flush Installation
  • 4-Wire Connection to SXL or PXL (Supervised)
  • 2 Remote Annunciators per SXL or PXL
  • Listed, ULC Listed, FM, CSFM, NYMEA Approved

Digital Alarm Communicators

5128 & 5129 Digital Alarm Communicators

  • 864 Listed. Meets NFPA 72 Chapter 4, for Central Station/Remote Station Monitoring
  • Listed as a Slave Communicator for Connection to System 3TM, SXL, IXL, and MXL Fire Alarm Control Panels
  • Four Fully Supervised Input Channels
  • Dual Phone Line Interface and Line Fault Monitoring
  • Automatic 24-Hour Test
  • Reports in Eight (8) Standard Communication Formats
  • Local Keypad Programmer/Annunciator (5230)
  • Remote Programming (Up/Down Loading)

Fire System Communicators
Communication of alarm and trouble information in and out of the protected building is critical to proper fire protection. The LED Series annunciators provide annunciation through-out the building in many formats to suit the building and the fire alarm control. The 5128 and 5129 communicators reliably carry system conditions to a central station.

Ordering Information

Model Part Number Description
LED-3 500-693062 8 Zone Serial Annunciator – Black, SXL & PXL
LED-4 500-693317 8 Zone Serial Annunciator – White, SXL & PXL
LED-8R 500-395661 8 Zone Annuniator – Red
LED-8B 500-395662 8 Zone Annuniator – Black
LED-8RTL 500-395663 8 Zone Annunciator – with Lamp Test & Trouble – Red
--- --- ---
LED-8BTL 500-395664 8 Zone Annunciator – with Lamp Test & Trouble – Black
LED-16R 500-395665 16 Zone Annunciator – Red
LED-16B 500-395666 16 Zone Annunciator – Black
LED-16RTL 500-395663 16 Zone Annunciator – with Lamp Test & Trouble – Red
LED-16BTL 500-395664 16 Zone Annunciator – with Lamp Test & Trouble – Black
5128 500-693213 4 Channel Communicator – Mounts inside FACP
5129 500-693214 4 Channel Communicator with Enclosure
5230 500-693215 Programmer/Annunciator for 5128 & 5129

MS Series Manual Fire Alarm Boxes

  • Durable Plastic Design
  • Shock and Vibration Resistant
  • Activation Visibly Noticeable
  • Optional Contact Arrangements
  • Options Include Keyswitch or Alarm Lamp
  • No Break Rods Necessary
  • Surface or Semi-Flush Installation
  • Metal Versions Available
  • Listed, FM and CSFM Approved

DT Series Thermal Fire Detectors

  • Fixed Temperatures 135°F and 200°F
  • Rate of rising
  • Rate Compensation / Fixed Temperature
  • Explosion-Proof Models Available
  • Weatherproof Models Available
  • Listed, ULC Listed, CSFM, NYMEA, and FM ApprovedCERBERUS-PYROTRONICS-Conventional-Fire-Alarm-Systems-fig- \(14\)

Initiating Devices
Cerberus Pyrotronics supplies a wide range of manual stations and thermal detectors to round out any installation. Outdoor use, explosion-proof environments, and other special applications can be satisfied with MS and DT series devices.

Cerberus Pyrotronics
8 Ridgedale Ave. Cedar Knolls, NJ 07927
Tel: 201-267-1300
FAX: 201-397-7008

4/97 10M CPY-IG Printed in the U.S.A.

Cerberus Pyrotronics
50 East Pearce Street Richmond Hill, Ontario L4B, 1B7 CN
Tel: 905-764-8384
FAX: 905-731-9182

firealarmresources.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CERBERUS PYROTRONICS User Manuals

Related Manuals