DELTA DOP-110DS HMI Panel Type 10.1 Inch TFT LCD Instructions

June 9, 2024
Delta

DELTA logo DOP-110DS HMI Panel Type 10.1 Inch TFT LCD
Instructions

General precautions

Thank you for purchasing this product. This DOP-107DV instruction sheet provides information for the DOP-107DV series HMI. Before using this product, read through this instruction sheet carefully to ensure the correct use of the product. Keep this sheet handy for quick reference whenever needed. Before finishing reading this sheet, follow the instructions below:

  • Install the product in an indoor location, which is free of vapor and corrosive and inflammable gas.
  • Refer to the wiring diagram when connecting the wires.
  • Ensure this product is correctly grounded. The grounding method must comply with the national electrical standard guidelines (refer to NFPA 70: National Electrical Code, 2005 Ed.).
  • Do not disassemble the HMI or change the wiring when power is on.
  • Do not touch the power supply when power is on, or it may cause electric shock.
  • When the HMI displays a low power notification and requires a battery change, contact Delta or local distributors for the replacement. Do not change the batteries by yourself.
  • This product can be used with other industrial automation equipment. Read through this sheet carefully and install the product according to the instructions to avoid danger.
  • Cleaning method: use a dry cloth to clean the product.
  • This product must be used at an altitude below 2,000 m (6561.68 ft).
  • If the equipment is used in a manner not specified by the manufacturer, the protection function provided by the equipment may be impaired.
  • For repair and maintenance, contact Delta Electronics, Inc. Address: No.18, Xinglong Rd.,
    T aoyuan City, T aiwan. TEL: +886-3-3626301.

If you have any inquiry during operation, contact our local distributors or Delta Customer Service Center.
The instruction sheet may be revised without prior notice. Contact our distributors or download the latest version from the Delta website (http://www.deltaww.com.tw/ia).

Communication port pin assignment

DOP-110DS COM1

COM Port

| Pin| MODE1| MODE2|

MOD E3

---|---|---|---|---
COM1| COM2| COM1| COM2| COM1| COM2
RS-232| RS-485| RS-485| RS-485| RS-232| RS-422
| 1| –| –| D+| –| –| TXD+
2| RXD| –| –| –| RXD| –
3| TXD| –| –| –| TXD| –
4| –| –| –| 0+| –| RXD+
5|

GND

| GND|

GN D

6| –| –| D-| —| –| TXD-
7| RTS| –| –| –| RTS| –
8| CTS| –| –| –| CTS| –
9| –| D-| –| D-| –| RXD-

Note: the mark “-” means connection is not required.

Description of each part

DOP-110DS (front view) ![DELTA DOP-110DS HMI Panel Type 10.1 Inch TFT LCD

A USB Host B USB Slave
C Power input connector (24AWG wire min.) D COM
E Ethernet (LAN)

Mounting dimensions

DOP-110DSDELTA DOP-110DS HMI Panel Type 10.1 Inch TFT LCD - fig
4 Note:
T=1.6 mm~6 mm(0.063″~0.24″)
Unit: mm (inch)
Operation temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: -20°C to 60°C (-4°F to 140°F)

Installation and wiring

Precautions:

  • Mount the HMI according to the following illustration. Incorrect installation direction may result in malfunction.
  • T o ensure the HMI is well ventilated, make sure there is sufficient space between the HMI and the adjacent objects or walls.
  • This product should be used on a case or platform which conforms to enclosure Type 4X standard (for indoor use only).
  • The maximum panel thickness for mounting must be no greater than 5 mm (0.2 inches).
  • Use copper wires.

Installation diagram:

Step 1: Put the waterproof gasket onto the HMI and then insert the HMI into the panel cutout. Step 2: Place the fasteners into the slots and tighten the screws until reaching the panel cutouts. Step 3: Tighten the screws with the torque between 0.5 N-M and 0.7 N-M to avoid damage to the plastic case. DOP-110DS torque: 6.17 lb-inch (0.7 N-M)

Step 4: For heat dissipation, keep a minimum clearance of 60 mm (2.36 inches) and 45 mm (1.77 inches) respectively on the rear and bottom of the HMI. Wiring:

Type Wire gauge (AWG) Stripped length Torque
Solid 24 – 12 7 – 8 mm
(0.28 – 0.31 inches) 5 kg-cm (4.3 lb-in)
Stranded 24 – 12 7 – 8 mm
(0.28 – 0.31 inches) 5 kg-cm (4.3 lb-in)

Refer to the following diagram when wiring the power connector. The temperature rating of the cable must be greater than 75°C (167°F).

Hardware specifications

Model DOP-110DS
Display Panel type
Resolution 1024 x 600 pixels
Backlight LED back light (half-life under room temperature 25°C > 30,000

hours) 1
Display range| 222.72 mm
125.28 mm
Brightness| 350 cd / m² (Typ.)
CPU| ARM Cortex-A8 (800 MHz)
Flash ROM| 256 Mbytes
RAM| 256 Mbytes
Touchscreen| 4-wire resistive touchscreen > 1,000,000 operated
Buzzer| Multi-tone frequency (2 – 4 kHz) / 80 dB
Network interface| 1 port, 10/100 Mbps auto-detection (with built-in isolated power circuit)2
USB| 1 USB Slave Ver 2.0; 1 USB Host Ver 2.0
SD| N/A
Serial communication port| COM1| RS-232 (supports flow control) / RS-485
2
COM2| RS-422 / RS-485 2
COM3| N/A
Auxiliary function key| N/A
Calendar| Built-in
Cooling method| Natural cooling
Approvals| CE / UL (use shielding network cable and magnetic ring with the filter of 300 ohm / 100 MHz)
Panel waterproof level| IP65 / NEMA4 / UL TYPE 4X (indoor use only)
Operation voltage
2| DC +24V (-15% to +15%) (use an isolated power supply)
Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation)
Leakage current| 500 VAC for 1 minute (between DC24V terminal and FG terminal)
Power consumption3| 7.14 W (Max) 3
Backup battery| 3V lithium battery CR2032 x 1
Backup battery life| About 3 years or more at 25°C (77°F)
(subject to operation temperature and condition)
Operation temperature| 0°C to 50°C (32°F to 122°F)
Storage temperature| -20°C to +60°C (-4°F to 140°F)
Operating environment| 10% to 90% RH [0 to 40°C (32°F to 104°F)],
10% to 55% RH [41 to 50°C (105.8°F to 122°F)], pollution degree: 2
Vibration resistance| Conforms to IEC61131-2: continuous vibration 5 Hz – 8.3 Hz with amplitude 3.5 mm; 8.3 Hz – 150 Hz with amplitude 1G
Shock resistance| Conforms to IEC60068-2-27: 11 ms, 15 G Peak, in X, Y, Z directions each for 6 times
Dimensions
(W) x (H) x (D) mm| 272.6 x 200.6 x 27.5
Mounting dimensions
(W) x (H) mm| 261.3 x 189.3
Weight| Approx. 1415 g

Note:

  1. The half-life of the backlight is defined as the maximum luminance being reduced by 50% when the maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at the room temperature of 25°C (77°F) with ambient humidity.
  2. The withstand voltage of the isolated power circuit is 1500V peak for 1 minute.
  3. The HMI power consumption is the power consumed when the HMI is not connecting with other peripheral devices. T o ensure normal operation of the HMI, the recommended capacity of the power supply is 1.5 to 2 times of the specified power consumption.
  4. Isolated power supply is recommended.
  5. For the programming software DOPSoft of DOP-100 series and its user manual, you can download them at http://www.delta.com.tw/ia.
  6. DOP-100 series can be used with other industrial automation equipment. Read through this sheet carefully and install the product according to the instructions to avoid danger.

Part Name

|

Hazardous Substances

---|---
(Pb)| (Hg)| (Cd)| (Cr Vi)| (PBB)| (PBDE)
Metal Part| X| O| O| O| O| O
Plastic Part| O| O| O| O| O| O
Electronic| X| O| O| O| O| O
Contacts| O| O| X| O| O| O
Cable & Cabling accessories| X| O| O| O| O| O
Bttery| O| O| O| O| O| O

This table is made according to SJ/T 11364.
O: Indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572.
X: Indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572.

DELTA logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals