POTTER PVC-MP-DP Network Audio System Owner’s Manual

June 9, 2024
POTTER

POTTER PVC-MP-DP Network Audio System

Features

  • Master Mic Control
  • 16 Switch Control Points
  • Dual Channel DMR and Audio Interface
  • High Speed Communication Loop
  •  25/50/100 Dual or Single Watt Amplifier (200W Single Channel optional), Dual/Single Amplification
  • Configuration for 4 or 8 Output Zones
  • 120 VAC Power Supply and Battery Charger
  • Live Microphone Override of Message and Tone
  •  Compatible High Reliability, No Maintenance, Fully Supervised
  • Easy Installation and Operation
  • Studio Quality Voice Recordings Built in Alarm and Alert Signals

Description

The PVC MP and DP panels operate with any Fire Alarm Control Panel (FACP) and provide 25, 50 or 100 Watts of speaker power. The panel has its own power supply and battery charger. The panel must be wired with 120 or 240 VAC and standby batteries connected. The PVC panel is housed in a surface or semi- flush mounted backbox with a hinged and key locked door.
The PVC-MP Master Panel (PVC-MP) utilizes a Master Mic control with 16 switch control points along with a
dual channel DMR and a high speed communication loop. Maximum system configuration allows up to 1,000 switch/input points, and an integrated fire phone is available as an option.
The PVC-DP Distributed Panel has 4 output zones available and can be configured for 8. The panel has dual channel audio interface and dual (25/50/100W available) or
single (25/50/100/200W available) channel amplification options. An integrated Fire Phone is optional, as well as 4 circuits expandable to 8, 12 or 16.with a maximum system configuration of up to 256 PVC-DP panels.

Technical Specifications

Dimensions 14.5” x 27” x 4” (W x H x D)
Primary Power 120 VAC
Battery Power 24 VDC
Electrical Ratings All circuits @ 24VDC
Voltage 5V peak to peak max
Frequency 1.024MHz
Current 50mA max.
Impedance 120 Ohms (max between panels)

Battery Charging

| EVX-25/50: 800mA, maximum battery

size 17Ah

EVX-100: 1A, maximum battery size 24Ah

Communications Bus| RS-485 standard, 1M Baud data rate, low capacitance cable
Color| Red

PVC-MP Master Panel Configurations

  • PVC-MP16 Master Panel, 16 Switch Control
  • PVC-MP32 Master Panel, 32 Switch Control
  • PVC-MP48 Master Panel, 48 Switch Control
  • PVC-MP64 Master Panel, 64 Switch Control
  • PVC-MP80 Master Panel, 80 Switch Control
  • PVC-MP96 Master Panel, 96 Switch Control
  • PVC-MP16/P Master Panel, 16 Switch Control, Master Fire Phone
  • PVC-MP32/P Master Panel, 32 Switch Control Master Fire Phone
  • PVC-MP64/P Master Panel, 64 Switch Control Master Fire Phone
  • PVC-MP80/P Master Panel, 80 Switch Control Master Fire Phone
  • PVC-MP96/P Master Panel, 96 Switch Control Master Fire Phone

Panel Options

Cards may be added as job requirements demand.

  • PVC-MFP Master Fire Phone Enables system to incorporate 2 way communication. Included with /P panels.
  • PVC-SSC Switch Scan Card Included in basic panels, up to 7 additional cards may be added.
  • PVC-SLC Switch LED Card 16 Switch LED Bank, up to 8 per PVC-SSC.
  • PVC-II Audio Module Interface Card One included with basic panel, additional cards give 16 control inputs each. Maximum of 8.

POTTER PVC-MP-DP Network Audio System-fig2

PVC-MP Master Panel Current for Components

Component| Standby| Alarm
DCC| 83 mA| 83 mA
ASC| 23 mA| 33 mA
MFP| 9 mA| 9 mA
SSC| 28 mA| 28 mA
SLC| 0.2 mA| 16 mA
MMC| 46 mA| 46 mA
IOI| 18 mA| 19 mA

PVC-DP Distributed Panel Configurations

  • PVC-DPS25 Distributed Panel, Single Channel, 25W
  • PVC-DPS50 Distributed Panel, Single Channel, 50W
  • PVC-DPS100 Distributed Panel, Single Channel, 100W
  • PVC-DPS25/P Distributed Panel, Single Channel, 25W, Fire Phone
  • PVC-DPS50/P Distributed Panel, Single Channel, 50W, Fire Phone
  • PVC-DPS100/P Distributed Panel, Single Channel, 100W, Fire Phone
  • PVC-DP25 Distributed Panel, Dual Channel, 25W
  • PVC-DP50 Distributed Panel, Dual Channel, 50W
  • PVC-DP100 Distributed Panel, Dual Channel, 100W, Single Channel 200W
  • PVC-DP25/P Distributed Panel, Dual Channel, 25W, Fire Phone
  • PVC-DP50/P Distributed Panel, Dual Channel, 50W, Fire Phone
  • PVC-DP100/P Distributed Panel, Dual Channel, 100W, Fire Phone, Single Channel 200W

Panel Options

Cards may be added as job requirements demand.

  • PVC-MBK Motherboard Relay card Expands MBR output to 8 Class B or 4 Class A circuits.
  • PVC-FPI Fire Phone Interface Card Included in /P panels, up to 3 additional cards may be added.
  • PVC-FPO Fire Phone Output Card Used with additional PVC-FPIs for termination.
  • PVC-II Audio Module Interface Card Included with basic panel, additional cards give the ability to control multiple modules

POTTER PVC-MP-DP Network Audio System-fig3

PVC-DP Distributed Panel Current for Components

Component| Standby| Alarm
DCC| 82 mA| 84 mA
MBR| 31 mA| 31 mA
AMI| 22 mA| 22 mA
FPI| 41 mA| 41 mA
MBK| 3 mA| 31 mA

Ordering Information PVC-MP

Description Stock No.
Master Panel, 16 Switch Control PVC-MP16
Master Panel, 32 Switch Control PVC-MP32
Master Panel, 48 Switch Control PVC-MP48
Master Panel, 64 Switch Control PVC-MP64
Master Panel, 80 Switch Control PVC-MP80
Master Panel, 96 Switch Control PVC-MP96
Master Panel, 16 Switch Control, Master Fire Phone PVC-MP16/P
Master Panel, 16 Switch Control, Master Fire Phone PVC-MP32/P
Master Panel, 16 Switch Control, Master Fire Phone PVC-MP64/P
Master Panel, 16 Switch Control, Master Fire Phone PVC-MP80/P
Master Panel, 16 Switch Control, Master Fire Phone PVC-MP96/P

Ordering Information PVC Panel Options

Description Stock No.
Master Fire Phone PVC-MFP
Switch Scan Card PVC-SSC
Switch LED Card PVC-SLC
Audio Module Interface Card PVC-II
Motherboard Relay Card PVC-MBK
Fire Phone Interface Card PVC-FPI
Fire Phone Output Card PVC-FPO
Audio Module Interface Card PVC-AMI

Ordering Information PVC-DP

Description Stock No.
Distributed Panel, Single Channel, 25W PVC-DPS25
Distributed Panel, Single Channel, 50W PVC-DPS50
Distributed Panel, Single Channel, 100W PVC-DPS100
Distributed Panel, Single Channel, 25W, Fire Phone PVC-DPS25/P
Distributed Panel, Single Channel, 50W, Fire Phone PVC-DPS50/P
Distributed Panel, Single Channel, 100W, Fire Phone PVC-

DPS100/P

Distributed Panel, Dual Channel, 25W| PVC-DP25
Distributed Panel, Dual Channel, 50W| PVC-DP50
Distributed Panel, Dual Channel, 100W, Single Channel 200W| PVC-DP100
Distributed Panel, Dual Channel, 25W, Fire Phone| PVC-DP25/P
Distributed Panel, Dual Channel, 50W, Fire Phone| PVC-DP50/P
Distributed Panel, Dual Channel, 100W, Fire Phone, Single Channel 200W| PVC- DP100/P

Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936www.pottersignal.com

firealarmresources.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals