POTTER P2 SERIES High Security Sensor Owner’s Manual
- June 9, 2024
- POTTER
Table of Contents
P2 SERIES High Security Sensor
Owner’s Manual
P2 SERIES
HIGH SECURITY SENSOR
P2 SERIES High Security Sensor
Stock number: 2020410 P2S-000 single contact
2020411 P2S-001 single contact w/ 1K embedded resistor
2020420 P2D-000 dual contact
- Listed to UL 634 Level 2 Standards
- Resistant to external and internal magnetic defeat
- Unique cross hole mounting feature eliminates need for L and Z brackets on most installations
- Retrofit for existing BMS devices
- No adjustment required for installation
- Industry’s most secure removal tamper sensor/circuit
- May be used as an intrinsically safe simple apparatus
- Resists permanent contact welding (lightning, power surges, stun guns)
- Single and dual alarm contacts available
- Hermetically sealed switch contacts
- Fully epoxy potted assembly
- Indoor or outdoor use
Experts agree that the most devastating threats to government and corporate
security have come from employees who were deemed trusted insiders. Armed with
simple magnets, unscrupulous insiders can disable even triple-balanced BMS
magnetic contacts while the system is unarmed, and enter undetected at a later
time, leaving no evidence of tamper.
The P2 High Security Switch (HSS) combined with Magnasphere technology meets
the UL 634 Level 2 High Security Standard. The P2 HSS meets standards for use
with SCIF and all other High Security Applications. The P2 HSS is resistant to
external and internal magnetic defeat. In addition, the switch resists
permanent contact welding due to lightning, power surges, or stun guns.
In addition to the sensors inside that will detect the presence of a stronger
defeat magnet placed on any surface of the HSS, the removal tamper circuit
will alarm before the HSS can be removed.
The construction of the HSS devices incorporates robust, hermetically sealed
Magnasphere switch technology as well as complete epoxy encapsulation of all
electrical components and magnetic actuation.
This allows the HSS models to conform to the requirements of UL 913 and be
used as an intrinsically safe simple apparatus device in hazardous locations.
The P2 HSS devices must be used in conjunction with an intrinsically safe
barrier.
Creative design of the P2 HSS switch itself eliminates the need for L or Z
brackets.
Aluminum Case | Silver grey anodized |
---|---|
Wire Lead Type | Solid color coded lead wires |
Single Alarm Contact (P2S) | Closed or open loop |
Dual Alarm Contact (P2D) | Closed loop |
Removal Tamper Circuit | Closed loop |
Max. Current | 0.25 A resistive |
Max. Voltage | 30 VDC |
Max. Power | 0.250 W |
Operating Temperature | -40°F to 176°F (-40°C to 80°C) |
Wiring
Single alarm contact either closed or open loop, with tamper circuit, closed
loop.
For built-in EOL resisitor configurations and values not shown, contact
Potter. Dual alarm contacts both closed loop, with tamper circuit, closed
loop.
For built-in EOL resistor configurations and values not shown, contact Potter.
Dimensions
Potter Electric Signal Co., LLC
St. Louis, MO
Cust Service: 866-240-1870
Tech Support:866-956-1211
Canada 888-882-1833
www.pottersignal.com
MKT. #8880142 – REV D
firealarmresources.com
References
- Fire Alarm Resources | Download fire alarm documents
- Potter Electric: Fire Alarms & Fire Sprinkler Systems