Danfoss PVH57-63 Variable Displacement Piston Pump Instructions

June 9, 2024
Danfoss

Danfoss PVH57-63 Variable Displacement Piston Pump Instructions

PVH57/63

FIG 1.JPG

FIG 2.JPG

FIG 3.JPG

FIG 4.JPG

FIG 5.JPG

FIG 6 Load Sensing & Pressure.JPG

FIG 7 Pressure Compensator Control C & CM.JPG

All parts shown are included in control kit.
Pressures must be set by user to circuit requirements.

FIG 8 Industrial Control \(IC\).JPG

FIG 9 Torque Limiter.JPG

FIG 10 A Thru –drive..JPG

FIG 11 A Thru –drive..JPG

Notes:

  1. ‘‘F ’’ type equal SAE threads
  2. ‘‘M’’ type equal metric threads
  3. ‘‘B’’ and ‘‘C’’ thru-drives created from ‘‘A’’ thru-drive pump with ‘‘B’’ or ‘‘C’’ thru-drive adapter kit installed.
  4. All screws/O-rings are included with each ‘‘kit’’ to convert from ‘‘A’’ to ‘‘B’’ or ‘‘C’’ thru-drive unit.

Typical Cross Section

FIG 12 Typical Cross Section.JPG

Note
Parts are shown as installed for right hand rotation. For left hand rotation, install control rod and control piston in valve block port #2. Install bias rod, bias piston and spring in valve block port #2.

Pump Startup
Make sure the reservoir and circuit are clean and free of dirt and debris prior to filling with hydraulic liuid.

Fill the reservoir with filtered oil to a level sufficient to prevent vortexing at suction connection to pump inlet. It is good practice to clean the system by flushing and filtering using an external slave pump.

Before starting the pump, fill with fluid through one of the ports. This is particularly important if the pump is above the fluid level of the reservoir.

When initially starting the pump, remove all trapped air from the system. This can be accomplished by loosening the pump outlet fittings or connections before starting the pump, or by using an air bleed valve. All inlet connections must be tight to prevent air leaks.

Once the pump is started, it should prime within a few seconds. If the pump does not prime, check to make sure that there are no air leaks in the inlet line and connections. Also check to make sure that trapped air can escape at the pump outlet.

After the pump is primed, tighten the loose outlet connections, then operate for five to ten minutes (unloaded) to remove all trapped air from the circuit. If reservoir has a sight gage, make sure the fluid is clear —not milky.

Add fluid to the reservoir up to the proper fill level.

Model Code

FIG 13 Model Code.JPG

FIG 14 Model Code.JPG

Products we offer:

  • Cartridge valves
  • DCV directional control valves
  • Electric converters
  • Electric machines
  • Electric motors
  • Gear motors
  • Gear pumps
  • Hydraulic integrated circuits (HICs)
  • Hydrostatic motors
  • Hydrostatic pumps
  • Orbital motors
  • PLUS+1® controllers
  • PLUS+1® displays
  • PLUS+1® joysticks and pedals
  • PLUS+1® operator interfaces
  • PLUS+1® sensors
  • PLUS+1® software
  • PLUS+1® software services, support and training
  • Position controls and sensors
  • PVG proportional valves
  • Steering components and systems
  • Telematics

Hydro-Gear
www.hydro-gear.com

Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com

Danfoss Power Solutions is a global manufacturer and supplier of high- quality hydraulic and electric components. We specialize in providing state- of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market as well as the marine sector. Building on our extensive applications expertise, we work closely with you to ensure exceptional performance for a broad range of applications. We help you and other customers around the world speed up system development, reduce costs and bring vehicles and vessels to market faster.

Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile electrification.

Go to www.danfoss.com for further product information.

We offer you expert worldwide support for ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide you with comprehensive global service for all of our components.

Local address:

Danfoss
Power Solutions (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000

Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumünster, Germany
Phone: +49 4321 871 0

Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222

Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 2080 6201

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals