Fein Dustex 25L Wet and Dry Vacuum Cleaner Instruction Manual

June 9, 2024
Fein

Fein logo Dustex 25L/ 35L Wet and Dry Vacuum Cleaner
Instruction ManualFein Dustex 25L Wet and Dry Vacuum
Cleaner

Dustex 25L Wet and Dry Vacuum Cleaner

FEIN Dustex 25L () – 9 20 35 …**

| | … 211240| … 223000| … 223080| … 223240
P1| W| 1000| 1200| 1200| 1200
PMax| W| 1000| 1380| 1380| 1380
PA| W| 750| 2200| 1100| 1800
U| V| 110| 220–240| 220–240| 220–240
f| Hz| 50/60| 50-60| 50-60| 50-60
| l| 22| 22| 22| 22
| l| 13| 13| 13| 13
| l/s| 30| 33| 33| 33
| l/s| 67| 72| 72| 72
| hPa| 213| 213| 213| 213
| kg| 8,6| 8,6| 8,6| 8,6
LpA| dB| 68| 68| 68| 68
KpA| dB| 2| 2| 2| 2
LwA| dB| 81| 81| 81| 81
ah| m/s²| < 2,5| < 2,5| < 2,5| < 2,5
Ka| m/s²| 0,2| 0,2| 0,2| 0,2
| | | | |
| | IPX4| IPX4| IPX4| IPX4
L x B x H| mm| 440 x 380 x 471
---|---|---
| | 3 13 45 250 01 0
| | 3 13 45 066 01 0
| | 3 13 45 061 01 0
| CELLULOSE| 3 13 45 012 01 0
| PES| 3 13 45 059 01 0
| HEPA| 3 13 45 060 01 0
FEIN Dustex 25L () – 9 20 35 …**

| | … 211240| … 223000| … 223080| … 223240
P1| W| 1000| 1200| 1200| 1200
PMax| W| 1000| 1380| 1380| 1380
PA| W| 750| 2200| 1100| 1800
U| V| 110| 220–240| 220–240| 220–240
f| Hz| 50/60| 50-60| 50-60| 50-60
| l| 32| 32| 32| 32
| l| 26| 26| 26| 26
| l/s| 30| 33| 33| 33
| l/s| 68| 72| 72| 72
| hPa| 213| 253| 253| 253
| kg| 9,6| 9,6| 9,6| 9,6
LpA| dB| 68| 68| 68| 68
KpA| dB| 2| 2| 2| 2
LwA| dB| 81| 81| 81| 81
ah| m/s²| < 2,5| < 2,5| < 2,5| < 2,5
Ka| m/s²| 0,2| 0,2| 0,2| 0,2
| | | | |
| | IPX4| IPX4| IPX4| IPX4
L x B x H| mm| 440 x 380 x 569
---|---|---
| | 3 13 45 250 01 0
| | 3 13 45 066 01 0
| | 3 13 45 062 01 0
| CELLULOSE| 3 13 45 012 01 0
| PES| 3 13 45 059 01 0
| HEPA| 3 13 45 060 01 0

Fein Dustex 25L Wet and Dry Vacuum Cleaner - Figure 1Fein Dustex 25L Wet and Dry Vacuum Cleaner - Figure
2Fein Dustex 25L Wet and Dry Vacuum Cleaner -
Figure 3Fein Dustex 25L Wet and Dry Vacuum
Cleaner - Figure 4Fein Dustex 25L Wet and
Dry Vacuum Cleaner - Figure 5Fein Dustex 25L Wet
and Dry Vacuum Cleaner - Figure 6Fein Dustex 25L Wet and Dry Vacuum Cleaner - Figure
7Fein Dustex 25L Wet and Dry Vacuum Cleaner -
Figure 8Fein Dustex 25L Wet and Dry Vacuum
Cleaner - Figure 9Fein Dustex 25L Wet and
Dry Vacuum Cleaner - Figure 10Fein Dustex 25L Wet and Dry Vacuum Cleaner - Figure
11

Translation of the Original Instructions.

Symbols, abbreviations and terms used.

Symbol, character Explanation
**** Make sure to read the enclosed documents such as the

Instruction Manual and the General Safety Instructions.
| Before commencing this work step, pull the mains plug out of the socket. Otherwise there will be danger of injury if the power tool should start unintentionally.
| Observe the instructions in the text or graphic opposite!
| Observe the instructions in the text or graphic opposite!
| Use eye protection during operation.
| Use ear protection during operation.
| Switching on
| Switching off
| Confirms the conformity of the power tool with the directives of the European Community.
| Confirms the conformity of the power tool with the directives of Great Britain (England, Wales, Scotland).
| Confirms the conformity of the power tool with the Guidelines of the European Customs Union.
| General prohibition sign. This action is prohibited.
| Additional information.
WARNING| This sign indicates a possible dangerous situation that could cause severe or fatal injury.
CAUTION| This sign warns of a possible dangerous situation that could cause injury.
****| Worn out power tools and other electrotechnical and electrical products should be sorted separately for environmental-friendly recycling.
| Product with basic insulation plus additional insulation on touchable, conductive parts connected to the protective conductor.
IPX4| Protection class
| Electrostatically conductive
Character| Unit of measurement,
international| Unit of measurement,
national| Explanation
---|---|---|---
P1| W| W| Power input
PMax| W| W| Power consumption, max.
PA| W| W| Max. connected load of the integrated socket outlet
U| V| V| Rated voltage
f| Hz| Hz| Frequency
| l| l| Container capacity
| l| l| Capacity for liquids
| l/s| l/s| Air flow with 4 m hose Ø 35 mm
| l/s| l/s| Air flow at fan
| hPa| hPa| Vacuum
L x B x H| mm| mm| Length x Width x Height
| mm| mm| Diameter of a round part
| kg| kg| Weight according to EPTAProcedure 01
Lw| h-1| h-1| Air-exchange rate
LpA| dB| dB| Sound pressure level
LwA| dB| dB| Sound power level
K…| | | Uncertainty
a| m/s²| m/s²| Vibrational emission value according to EN 60745 (vector sum of three directions)
| m, s, kg, A, mm, V, W, Hz, N, °C, dB,2 min, m/s| m, s, kg, A, mm, V, W, Hz, N, °C, dB,2 min, m/s| Basic and derived units of measurement from the international system of units SI.

For your safety.

WARNING: Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
Do not use this vacuum cleaner before your have thoroughly read and completely understood this instructions manual and the enclosed “safety warnings”. The documents mentioned should be kept for later use and enclosed with the vacuum cleaner, should it be passed on or sold.
Please also observe the relevant national industrial safety regulations.

Intended use of the vacuum cleaner:

Wet/dry vacuum cleaner for vacuuming and extraction of dry, nonhazardous dusts of dust category L, minor dust particles, particularly when carrying out dust- forming work with a power tool, and noncombustible liquids, in weather- protected environments using the application tools and accessories recommended by FEIN.
This vacuum cleaner is intended for commercial use, such as in hotels, schools, hospitals, factories, shops, offices and rental businesses.
Only for EU countries:
Vacuum cleaners of dust category L according to IEC/EN 60335-2-69 for dry vacuuming of hazardous dusts with an exposition limit value > 1 mg/m 3.
Only for Switzerland:
The vacuum cleaner’s socket outlet may only be used in dry environments.
WARNING: The vacuum cleaner contains materials that are hazardous to one’s health. Have the emptying and maintenance, incl. the disposal of dustcollection containers, carried out only by specialists. Appropriate protective equipment is required. Do not operate the vacuum cleaner without the complete filter system. Otherwise there is danger to your own health.
WARNING: The vacuum cleaner contains materials that are hazardous to one’s health. Have the emptying and maintenance, incl. the disposal of dustcollection containers, carried out only by specialists. Appropriate protective equipment is required. Do not operate the vacuum cleaner without the complete filter system. Otherwise there is danger to your own health.
This vacuum cleaner is also suitable for use with AC generators with sufficient power output that correspond the the Standards ISO 8528, design type G2. This Standard is particularly not complied with when the so-called distortion factor exceeds 10 %. When in doubt, please refer to the generator instructions/specification guide.

Special safety instructions.

This machine is not intended to be used by persons (including children) with limited physical, sensory or mental capabilities, or lack of experience and/or knowledge. Children should be supervised in order to ensure that they do not play with the machine.
Cleaning and maintenance of the vacuum cleaner shall not be made by children without supervision.
**WARNING: Operating personnel must be appropriately instructed in the use of this vacuum cleaner. Before usage, the person operating the vacuum cleaner must have been provided with information, instructions and training on using the vacuum cleaner and the materials to be vacuumed, including the safe procedure for disposal of vacuumed materials. The person operating the vacuum cleaner must observe the relevant safety regulations for the materials being vacuumed.
Wear personal protective equipment. Depending on application, use face shield, safety goggles or safety glasses. Where appropriate, wear dust mask, hearing protectors, gloves and workshop apron capable of stopping small abrasive or workpiece fragments. The eye protection must be capable of stopping flying debris generated by various operations. The dust mask or respirator must be capable of filtrating particles generated by your operation. Prolonged exposure to high intensity noise may cause hearing loss.
Operate the vacuum cleaner only from socket outlets with earthing contact that are according to regulations. Use only undamaged supply cords and regularly checked extension cords with earthing contact. A protective conductor without continuity can lead to electric shock. The earthed connection socket discharges static charges. In connection with electrostatically discharging accessories (optional), this prevents the formation of sparks and current surges.
When wet vacuuming, operate the vacuum cleaner only when the container is level. Otherwise there is danger of electric shock from water penetrating into the vacuum  leaner motor.
Do not misuse the power supply cord to pull the vacuum cleaner around or pull the mains plug from the socket outlet. Keep the power supply cord away from heat, oil sharp edges, or moving parts. Do not drive over or pinch the power supply cord. Damaged or entangled power supply cords increase the risk of an electric shock.
Before replacing accessories, pull the mains plug from the socket outlet. This safety measure reduces the risk of electric shock.
Do not vacuum materials that are hazardous to one’s health, e. g., dust from beech or oak wood, masonry dust, asbestos. These materials are considered carcinogenic.
When vacuuming larger quantities of fine dust, electrostatic charging may occur.
Provide for good ventilation of the workplace.
Do not vacuum inflammable or explosive fluids; for example, benzene, oil, alcohol, solvents. Do not vacuum hot or inflammable dusts. Do not operate the vacuum cleaner in rooms where the danger of an explosion exists. The dusts, vapours or fluids can ignite or explode.
Do not rivet or screw any nameplates or designs to the vacuum cleaner. If the insulation is damaged, protection against an electric shock will be ineffective. Adhesive labels are recommended.
Do not use accessories not specifically intended or recommended for this vacuum cleaner. Just because the accessory can be attached to your vacuum cleaner, it does not assure safe operation.
Before starting operation (see page 6–9), check the power supply cord and the mains plug for damage.
****
WARNING:** Use the vacuum cleaner’s socket outlet only for connection of an external power tool. The vacuum cleaner is automatically switched on and off via the connected power tool. The connected load of the power tool may not exceed the maximum connected load PA of the vacuum cleaner’s socket outlet.
Please also observe the operating instructions and safety warnings of the power tool being connected to the socket outlet of the vacuum cleaner.
Recommendation: Always operate the vacuum cleaner via a residual current device (RCD) with a rated residual current of 30 mA or less. The vacuum cleaner may only be stored indoors.

Operating Instructions.

Operation, see page 10.
Filter replacement and filter cleaning, see page 11–13/ 30 section “Fault Finding.”
Never vacuum without the flat-fold filter, as otherwise the motor will be damaged and a health hazard will occur through increased exposure of fine dust. When vacuuming fine dust, a fleece filter bag must be used additionally.
An adequate ventilation rate L must be provided for when the outgoing air is circulated. The circulated airflow must not exceed 50 % (max.) of the fresh air volume (room volume x ventilation rate Lw). The following applies without special ventilation measures: Lw =1h -1.
When inserting the fleece filter bag, pay attention that the closing cover and the fleece bag face completely against the interior side of the container.
After removing the fleece filter bag, seal it with the closing cover in order to avoid debris.
For vacuuming dusts of dust category L, only dry flat-fold filters, which have not been moist or wet, are permitted to be used.
Before switching from wet to dry vacuuming, allow the flatfold filter to dry or replace through a dry one. Otherwise, the flat-fold filter will become unusable.
Keep the flat-fold filter dry and clean it regularly.
Mount accessories applying only slight pressure. For disassembling, turn the parts somewhat against each other and pull apart.
Switch the vacuum cleaner off before connecting a power tool to the vacuum cleaner’s socket outlet. Make sure that the power tool is switched off when inserting its plug into the vacuum cleaner’s socket outlet. After switching off a power tool connected to the vacuum cleaner’s socket outlet, the vacuum cleaner will run on for approx. 15 seconds and then automatically switch off. When wet vacuuming electrically conductive liquids, the vacuum cleaner is automatically switched off (automatic shut-off) when reaching the maximum filling height of the container. Pull the mains plug from the socket outlet and empty the container.
When wet vacuuming electrically non-conductive liquids (e. g., oils, drilling emulsions), the vacuum cleaner is not automatically switched off when reaching the maximum filling height of the container. Empty the container in time.
After finishing the wet vacuuming, clean the sensors and the space in between using a brush.
**WARNING:** Check the sensors regularly for signs of damage.
Switch the vacuum cleaner off immediately as soon as foam or water comes out, and empty the container.
In case of a short-circuit and/or heavy discharge of dust, switch the vacuum cleaner off immediately and disconnect it from the power supply.
For transport of the vacuum cleaner, activate the vacuum cleaner’s lockable castor brake.

Repair and customer service.

Check the connections, seals and hoses. Have damage repaired only through a qualified repair person and only using original FEIN replacement parts.
Use commercially available, nonscouring cleaning agents and water for cleaning the vacuum cleaner.
After cleaning, allow the vacuum cleaner to dry completely.
Empty the container each time after using and remove coarse debris and dust.
Empty the container after vacuuming liquids. Afterwards, run the vacuum cleaner with the accessories connected for several minutes in order to dry them.
Dispose of used flat-fold filters and filter bags according to statutory regulations.
When the machine’s power supply cord is damaged, it must be replaced by the manufacturer or their representative.
Have a dust-technical inspection carried out at least once every year by the manufacturer or an instructed person, e. g., for damage of the filter, function and tightness against leakage of the vacuum cleaner.
For category L vacuum cleaners that were in contaminated environments, the exterior as well as all machine parts should be cleaned or treated with sealants. When performing maintenance and repair work, all contaminated components that cannot be cleaned to satisfactory must be disposed of. Such components must be disposed of in impermeable plastic bags conforming with the valid regulations for the disposal of such waste.
For maintenance on behalf of the user, the vacuum cleaner must be disassembled, cleaned and maintained as far as feasible, without causing a risk for the maintenance personnel or other persons. Prior to disassembly, the vacuum cleaner should be cleaned in order to prevent any risks. The room/enclosure in which the vacuum cleaner is disassembled should be well ventilated. Wear personal protective equipment during maintenance. After the maintenance, the maintenance area should be cleaned.
Products that have come into contact with asbestos may not be sent in for repair. Dispose of products contaminated with asbestos according to the applicable countryspecific regulations for such disposal.
The current spare parts list for this vacuum cleaner can be viewed on the Internet at www.fein.com.
If required, you can change the following parts yourself:
Fleece filter bag, flat-fold filter, filter cartridge, hose, tool sleeve

Fault Finding.

Malfunction Cause Troubleshooting

Vacuum cleaner cannot be switched
on.| Circuit breaker of power connection has
tripped.| Ensure power supply.
Vacuum cleaner in remote control operation.| Set operating-mode selector switch to “I”.
Reduced vacuuming capacity.| Vacuum cleaner not fitted correctly.| Mount vacuum cleaner lid properly and completely close both
fasteners.
Vacuum system clogged.| Clean vacuum hose and extension tubes.
Fleece filter bag full.| Replace fleece filter bag.
Flat-fold filter full.| Replace flat-fold filter.
Dust escapes during vacuuming.| Incorrect installation position of flat-fold filter| Correct installation position of flat-fold filter.
No suction capacity when wet vacuuming.| Container full.| Empty container.
Automatic shut-off does not actuate.| Sensors soiled/dirty.| Clean sensors and space in between with a brush.

Warranty and liability.

The warranty for the product is valid in accordance with the legal regulations in the country where it is marketed. In addition, FEIN also provides a guarantee in accordance with the FEIN manufacturer’s warranty declaration.
The delivery scope of your vacuum cleaner may include only a part of the accessories described or shown in this instruction manual.

Declaration of conformity.

This CE declaration is only valid for European Union and EFTA (European Free Trade Association) countries and only for products intended for the EU- or EFTA market. After placing the product on the EU market the UKCA mark loses its mark validity.
The UKCA declaration is only valid for the Great
Britain market (England, Wales and Scotland) and only for products intended for the Great Britain market. After placing the product on the Great Britain market the CE mark loses its mark validity.
FEIN declares itself solely responsible for this product conforming with the relevant provisions given on the last page of this Instruction Manual.
Technical documents at:
C. & E. Fein GmbH
Hans-Fein-Straße 81
73529 Schwäbisch Gmünd-Bargau,
Germany

Environmental protection, disposal.

Packaging, worn out vacuum cleaners and accessories should be sorted for environment-friendly recycling.

This CE declaration is only valid for European Union and EFTA (European Free Trade Association) countries and only for products intended for the EU or EFTA market.
After placing the product on the EU market the UKCA mark loses its mark validity.
The UKCA declaration is only valid for the Great Britain market (England, Wales and Scotland) and only for products intended for the Great Britain market. After placing  the product on the Great Britain market the CE mark loses its mark validity.

**** ****

EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 +
A1:2019 + A14:2019 + A2:2019
EN 60335-2-69:2012
EN 55014-1:2017+A11:2020
EN 55014-2:1997+A1:2001+A2:2008
EN 55014-2:2015+Cor:2016
EN 61000-3-2:2014
EN 61000-3-2:2019
EN 61000-3-3:2013
EN 61000-3-3:2013+A1:2019
EN 62233:2008
2006/42/EG, 2014/30/EU,
2011/65/EU| EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 +
A1:2019 + A14:2019 + A2:2019
EN 60335-2-69:2012
EN 55014-1:2017+A11:2020
EN 55014-2:1997+A1:2001+A2:2008
EN 55014-2:2015+Cor:2016
EN 61000-3-2:2014
EN 61000-3-2:2019
EN 61000-3-3:2013
EN 61000-3-3:2013+A1:2019
EN 62233:2008
Supply of Machinery Regulations 2008, EMC Regulation 2016, The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
| | |
---|---|---|---
i. V. S. Böhm
Director of Quality
Management| i. V. Dr. M. Hergesell
Director of Product
Development| i. V. Dr. M. Hergesell
Director of Product
Development| i. V. Dr. M. Hergesell
Director of Product
Development
Schwäbisch Gmünd-Bargau, 11.06.2021| Schwäbisch Gmünd-Bargau, 11.06.2021

Fein logo 34101265060
C. & E. Fein GmbH
Hans-Fein-Straße 81
73529 Schwäbisch Gmünd-Bargau, Germany
www.fein.com
Printed in Romania. 3 41 01 265 06 0. 2022-10-18.