TRANE DXHG Water Source Heat Pump Axiom User Guide
- June 9, 2024
- Trane
Table of Contents
TRANE DXHG Water Source Heat Pump Axiom
Copyright
This document and the information in it are the property of Trane, and may not
be used or reproduced in whole or in part without written permission. Trane
reserves the right to revise this publication at any time, and to make changes
to its content without obligation to notify any person of such revision or
change.
Trademarks
All trademarks referenced in this document are the trademarks of their
respective owners.
Revision History
- Updated EXHG009-0024 and 030-070 models general data table.
- Updated DXHG024-070 model general data table.
- Updated Clearance – EXHG/DXHG 0.75 to 6 tons.
Table 1. List of options
Factory Installed Options | Field Installed Options |
---|---|
1-inch or 2-inch Ducted Filter Rack | 2-inch or 4-inch Ducted Filter Rack |
Air-Fi® Wireless Communications | Ducted Panel |
Deluxe 24V, UC400B Controls | Hose Kits (or ship separate hoses and valves) |
Factory-mounted Isolation Valve | Low, Medium and High Electric Heat |
Hot Gas Reheat | Pump Module |
Matte or Foil Face Insulation | Pump Module Hose Kit |
MERV 8 or 13 Filters | Thermostats or Zone Sensors |
Polymer or Stainless Steel IAQ Drain Pan | Waterside Economizer |
Recessed Unit Mounted Disconnect Switch |
Standard or Deluxe Sound Package
Table 2. General data – models EXHG009-024
Model EXHG | 009 | 012 | 015 | 018 | 024 |
---|---|---|---|---|---|
Unit size width x depth x height (in.) | 25.5 x 46 x 17.75 | 25.5 x 46 x 17.75 | |||
25.5 x 49 x 18.75 | 25.5 x 55 x 19.75 | 25.5 x 55 x 19.75 | |||
Compressor type | Rotary | Rotary | Rotary | Rotary | Scroll |
Net weight (lbs.) | 173 | 173 | 173 | 269 | 269 |
Ship weight (lbs.) | 297 | 297 | 297 | 393 | 393 |
Filter size nominal (in.) | 16 x 19 | 17 x 19 | 17 x 20 | 18 x 23 | 19 x 23 |
Water in/out size (FPT) | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 |
Condensate size (NPTI) | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 |
Blower wheel Size (in.) | 9 x 8 | 9 x 8 | 10 x 8 | 10 x 9 | 10 x 9 |
Table 3. General data – models EXHG030-070
Model EXHG | 030 | 036 | 042 | 048 | 060 | 070 |
---|---|---|---|---|---|---|
Unit size width x depth x height (in.) | 28 x 68 x 21.75 | 28 x 68 x 21.75 | ||||
29.38 x 77.75 x 22.13 | 29.38 x 77.75 x 22.13 | 29.38 x 86.75 x 22.13 | 29.38 x |
86.75 x 22.13
Compressor type| Scroll| Scroll| Scroll| Scroll| Scroll| Scroll
Net weight (lbs.)| 313| 313| 381| 381| 434| 434
Ship weight (lbs.)| 458| 458| 560| 560| 613| 613
Filter size nominal (in.)| 20 x 30| 20 x 30| 20 x 20 (qty-2)| 20 x 20 (qty-2)|
30 x 20
20 x 20
| 30 x 20
20 x 20
Water in/out size (FPT)| 3/4| 3/4| 1.00| 1.00| 1.00| 1.00
Condensate size (NPTI)| 3/4| 3/4| 3/4| 3/4| 3/4| 3/4
Blower wheel Size (in.)| 11 x 11| 11 x 11| 11 x 11| 11 x 11| 11 x 11| 11 x 11
Table 4. General data – models EXVG009-030
Model EXVG | 009 | 012 | 015 | 018 | 024 | 030 |
---|---|---|---|---|---|---|
Unit size width x depth x height (in.) | 21.5 x 21.5 x 34 | 21.5 x 21.5 x 34 | ||||
21.5 x 23 x 36 | 21.5 x 26 x 38 | 21.5 x 26 x 38 | 24 x 32.5 x 42 | |||
Compressor type | Rotary | Rotary | Rotary | Rotary | Scroll | Scroll |
Net weight (lbs.) | 152 | 152 | 188 | 222 | 236 | 280 |
Ship weight (lbs.) | 207 | 207 | 246 | 282 | 296 | 343 |
Filter size nominal (in.) | 16 X 19 | 16 X 19 | 17 X 20 | 18 X 23 | 18 X 23 | 20 X |
30
Water in/out size (FPT)| 0.50| 0.50| 0.75| 0.75| 0.75| 1.00
Model EXVG| 009| 012| 015| 018| 024| 030
---|---|---|---|---|---|---
Condensate size (NPTI)| 0.75| 0.75| 0.75| 0.75| 0.75| 0.75
Blower wheel Size (in.)| 9 x 8| 9 x 8| 10 x 8| 10 x 9| 10 x 9| 11 x 11
Table 5. General data – models EXVG036-070
Model EXVG | 036 | 042 | 048 | 060 | 070 |
---|---|---|---|---|---|
Unit size width x depth x height (in.) | 24 x 32.5 x 42 | 25.4 x 32.5 x 49 | 25.4 | ||
x 32.5 x 49 | 25.4 x 32.5 x 55 | 25.4 x 32.5 x 55 | |||
Compressor type | Scroll | Scroll | Scroll | Scroll | Scroll |
Net weight (lbs.) | 281 | 329 | 345 | 367 | 432 |
Ship weight (lbs.) | 344 | 394 | 410 | 436 | 501 |
Filter size nominal (in.) | 20 X 30 | 27 X 30 | 27 X 30 | 30 X 33 | 30 X 33 |
Water in/out size (FPT) | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Condensate size (NPTI) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Blower wheel Size (in.) | 11 x 11 | 11 x 11 | 11 x 11 | 11 x 11 | 11 x 11 |
Table 6. General data – models DXHG024-070
Model DXHG | 024 | 036 | 048 | 060 | 070 |
---|---|---|---|---|---|
Unit size width x depth x height (in.) | 25.5 x 55 x 19.75 | 28 x 68 x 21.75 | |||
29.38 x 77.75 x 22.13 | 29.38 x 86.75 x 22.13 | 29.38 x 86.75 x 22.13 | |||
Compressor type | Two-Stage Scroll | Two-Stage Scroll | Two-Stage Scroll | Two- | |
Stage Scroll | Two-Stage Scroll | ||||
Net weight (lbs.) | 269 | 313 | 381 | 434 | 434 |
Ship weight (lbs.) | 393 | 458 | 560 | 613 | 613 |
Filter size nominal (in.) | 18 x 23 | 20 x 30 | 20 x 20 (qty-2) | 30 x 20 |
20 x 20
| 30 x 20
20 x 20
Water in/out size (FPT)| 3/4| 3/4| 1.00| 1.00| 1.00
Condensate size (NPTI)| 3/4| 3/4| 3/4| 3/4| 3/4
Blower wheel Size (in.)| 10 x 9| 11 x 11| 11 x 11| 11 x 11| 11 x 11
Table 7. General data – models DXVG024-070
Model DXVG | 024 | 036 | 048 | 060 | 070 |
---|---|---|---|---|---|
Unit size width x depth x height (in.) | 21.5 x 26 x 38 | 24 x 32.5 x 42 | 25.4 x | ||
32.5 x 49 | 25.4 x 32.5 x 55 | 25.4 x 32.5 x 55 | |||
Compressor type | Two-Stage Scroll | Two-Stage Scroll | Two-Stage Scroll | Two- | |
Stage Scroll | Two-Stage Scroll | ||||
Net weight (lbs.) | 236 | 279 | 354 | 371 | 437 |
Ship weight (lbs.) | 296 | 342 | 419 | 440 | 506 |
Filter size nominal (in.) | 18 x 23 | 23 x 30 | 27 x 30 | 30 x 33 | 30 x 33 |
Water in/out size (FPT) | 0.75 | 1.00 | 1.00 | 1.00 | 1.00 |
Condensate size (NPTI) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Blower wheel Size (in.) | 10 x 9 | 11 x 11 | 11 x 11 | 11 x 11 | 11 x 11 |
Table 8. ANSI/AHRI/ASHRAE/ISO13256-1 WLHP, GWHP and GLHP performance – 0.75 to 6 tons
Model
|
Rated GPM
|
Rated CFM
| Water Loop Heat Pump| Ground Water Heat Pump| Ground Loop Heat
Pump
---|---|---|---|---|---
Cooling 86°F| Heating 68°F| Cooling 59°F| Heating 50°F|
Full Cool 77°F| Full Heat 32°F
Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
EXV/H009| 2.25| 285| 7900| 16.10| 9900| 5.6| 8800| 25.0| 8200| 4.8| 8300|
18.8| 6100| 3.7
EXV/H012| 3.00| 380| 11600| 16.40| 15200| 5.8| 13700| 27.9| 12300| 5.0| 12300|
19.5| 9300| 4.0
EXV/H015| 3.75| 475| 15100| 16.10| 18700| 5.3| 17000| 25.8| 15300| 4.6| 15800|
19.0| 12100| 3.8
EXV/H018| 4.50| 570| 18800| 17.60| 23600| 5.7| 21100| 28.7| 18800| 4.9| 19600|
20.6| 14600| 4.1
EXV/H024| 6.00| 760| 24600| 17.40| 32100| 5.7| 27400| 27.2| 25900| 5.0| 25600|
20.3| 19500| 3.9
EXV/H030| 7.50| 950| 31400| 17.80| 38400| 5.8| 35000| 27.2| 31000| 5.0| 32800|
20.7| 23600| 4.1
EXV/H036| 9.00| 1140| 35500| 17.60| 43100| 5.8| 39400| 26.5| 35000| 5.0|
37100| 20.4| 27200| 4.1
EXV/H042| 10.50| 1330| 38400| 18.00| 48000| 6.4| 43300| 27.5| 38500| 5.5|
40500| 21.1| 29400| 4.3
EXV/H048| 12.00| 1520| 45400| 17.70| 55600| 6.1| 50400| 26.4| 44800| 5.3|
47100| 20.3| 34600| 4.3
EXV/H060| 15.00| 1900| 55700| 17.50| 69000| 5.9| 60800| 25.7| 55900| 5.1|
57700| 20.1| 42900| 4.1
EXV/H070| 17.50| 2215| 63800| 17.30| 82100| 5.40| 68900| 24.9| 66900| 4.8|
66100| 19.80| 52000| 4.1
Note: Rated in accordance ANSI/AHRI/ASHRAE/ISO13256-1. Certified conditions are 80.6°F DB/66.2°F WB EAT in cooling and 68°F DB/59°F WB EAT in heating. Entering liquid temperature in cooling is 86°F for Water Loop, 77°F for Ground Loop (full load), 68°F for Ground Loop (part load), and 59°F for Ground Water. Entering liquid temperature in heating is 68°F for Water Loop, 32°F for Ground Loop (full load), 41°F for Ground Loop (part load), and 50°F for Ground Water.
Table 9. ANSI/AHRI/ASHRAE/ISO13256-1 WLHP, GWHP and GLHP performance – 2 to 6 tons
Model
|
Load
|
Rated GPM
|
Rated CFM
| Water Loop Heat Pump| Ground Water Heat Pump| Ground Loop Heat
Pump
---|---|---|---|---|---|---
Cooling 86°F| Heating 68°F| Cooling 59°F| Heating 50°F|
Full Cool 77°F| Full Heat 32°F
Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
DXV/H024| Full| 6.0| 760| 24700| 16.8| 32100| 5.5| 27500| 24.4| 25700| 4.9|
25900| 19.2| 19400| 3.9
DXV/H024| Part| 6.0| 608| 18500| 17.7| 24100| 5.9| 20500| 28.3| 18900| 4.9|
20000| 24.5| 16300| 4.3
DXV/H036| Full| 9.0| 1140| 33000| 17.3| 40900| 5.9| 37100| 25.1| 32900| 5.1|
34500| 19.7| 25500| 4.1
DXV/H036| Part| 9.0| 912| 24500| 18.3| 30500| 6.3| 27600| 29.3| 24300| 5.2|
26600| 25.2| 21100| 4.5
DXV/H048| Full| 12.0| 1520| 45200| 17.9| 55200| 6.1| 50400| 26.4| 44400| 5.3|
46600| 20.6| 34500| 4.3
DXV/H048| Part| 12.0| 1216| 32800| 18.7| 40000| 6.6| 36900| 31.2| 31900| 5.3|
35700| 26.7| 28000| 4.7
DXV/H060| Full| 15.0| 1900| 52100| 17.6| 63900| 6.0| 56600| 24.8| 51700| 5.2|
53900| 19.9| 39800| 4.2
DXV/H060| Part| 15.0| 1520| 38300| 18.7| 47300| 6.6| 42000| 29.9| 37800| 5.4|
41000| 25.8| 32400| 4.6
DXV/H070| Full| 17.5| 2215| 64400| 17.3| 82700| 5.4| 69100| 23.8| 67400| 4.8|
66800| 19.6| 52900| 4.0
DXV/H070| Part| 17.5| 1772| 47100| 18.9| 59700| 6.0| 51100| 29.7| 48000| 5.0|
50000| 25.6| 42000| 4.4
Note: Performance data EXVG 0.5 Ton or 0.75 Ton Rated in accordance with ANSI/AHRI/ASHRAE/ISO13256-1. Certified conditions are 80.6°F DB/66.2°F WB EAT in cooling and 68°F DB/59°F WB EAT in heating. Entering liquid temperature in cooling is 86°F for Water Loop, 77°F for Ground Loop (full load), 68°F for Ground Loop (part load), and 59°F for Ground Water. Entering liquid temperature in heating is 68°F for Water Loop, 32°F for Ground Loop (full load), 41°F for Ground Loop (part load), and 50°F for Ground Water.
*Table 10. Electrical data – 0.75 to 6 tons, EX009-070**
Model No.| Unit Volts| Blower Motor HP| Minimum Circuit
Ampacity| Maximum Overcurrent Protective Device
---|---|---|---|---
DXH/DXV024| 208-230/60/1| 1/2| 17/17| 25/25
DXH/DXV024| 265/60/1| 1/2| 13| 20
DXH/DXV024| 208-230/60/3| 1/2| 10/10| 15/15
DXH/DXV024| 460/60/3| 1/2| 6| 15
DXH/DXV036| 208-230/60/1| 3/4| 19/19| 30/30
DXH/DXV036| 265/60/1| 3/4| 15| 20
DXH/DXV036| 208-230/60/3| 3/4| 13/13| 20/20
DXH/DXV036| 460/60/3| 1| 7| 15
DXH/DXV048| 208-230/60/1| 1| 25/25| 40/40
DXH/DXV048| 208-230/60/3| 1| 21/21| 30/30
DXH/DXV048| 460/60/3| 1| 10| 15
DXH/DXV060| 208-230/60/1| 1| 31/31| 50/50
DXH/DXV060| 208-230/60/3| 1| 22/22| 35/35
DXH/DXV060| 460/60/3| 1| 10| 15
DXH/DXV070| 208-230/60/1| 1| 39/39| 60/60
DXH/DXV070| 208-230/60/3| 1| 26/26| 40/40
DXH/DXV070| 460/60/3| 1| 12| 15
Model No.| Unit Volts| Blower Motor HP| Minimum Circuit
Ampacity| Maximum Overcurrent Protective Device
---|---|---|---|---
EXH/EXV018| 208-230/60/1| 1/2| 12/12| 20/20
EXH/EXV018| 265/60/1| 1/2| 10| 15
EXH/EXV024| 208-230/60/1| 1/2| 19/19| 30/30
EXH/EXV024| 265/60/1| 1/2| 13| 20
EXH/EXV024| 208-230/60/3| 1/2| 11/11| 15/15
EXH/EXV024| 460/60/3| 1/2| 6| 15
EXH/EXV030| 208-230/60/1| 3/4| 20/20| 30/30
EXH/EXV030| 265/60/1| 3/4| 16| 25
EXH/EXV030| 208-230/60/3| 3/4| 13/13| 20/20
EXH/EXV030| 460/60/3| 3/4| 7| 15
EXH/EXV036| 208-230/60/1| 3/4| 23/23| 35/35
EXH/EXV036| 265/60/1| 3/4| 17| 25
EXH/EXV036| 208-230/60/3| 3/4| 15/15| 20/20
EXH/EXV036| 460/60/3| 1| 7| 15
EXH/EXV042| 208-230/60/1| 3/4| 25/25| 40/40
EXH/EXV042| 208-230/60/3| 3/4| 17/17| 25/25
EXH/EXV042| 460/60/3| 1| 9| 15
EXH/EXV048| 208-230/60/1| 1| 25/25| 40/40
EXH/EXV048| 208-230/60/3| 1| 20/20| 30/30
EXH/EXV048| 460/60/3| 1| 9| 15
EXH/EXV060| 208-230/60/1| 1| 31/31| 50/50
EXH/EXV060| 208-230/60/3| 1| 22/22| 35/35
EXH/EXV060| 460/60/3| 1| 10| 15
EXH/EXV070| 208-230/60/1| 1| 39/39| 60/60
EXH/EXV070| 208-230/60/3| 1| 26/26| 40/40
Clearances – EXHG/DXHG 0.75 to 6 tons
A minimum 14-inch clearance for servicing the unit is required for all EXH 0.75 to 6 tons configurations from other mechanical and electrical equipment (where shown) to enable panel removal from the unit for service/maintenance ability. The optimum clearance required is 20 inches.
A 24-inch clearance from other mechanical and electrical equipment (where shown) is recommended for most unit configurations. This will enable panel removal from the unit for service/maintenance. The 24-inch side clearance on EXVG/DXVG 0.75-6T models is for optimal access only. Side clearance is not a requirement as most components can be accessed from the front of the unit.
A 1-inch minimum clearance between the filter rack and any obstacle is required for units in a free return application to provide proper air flow to the air-to-refrigerant coil. A 12-inch minimum clearance between the filter rack and any obstacle should be provided to properly attached ductwork.The 1-inch dimension shown in the back of the unit represents the supply duct collar for the back supply option. This clearance is needed to clear these flanges.
Trane – by Trane Technologies (NYSE: TT), a global climate innovator – creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or tranetechnologies.com.
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
WSHP-PRC030C-EN 01 Mar 2023 Supersedes WSHP-PRC030B-EN (Oct 2021)
References