INSTALLATION

The subfloor must be clean and dry and if necessary, smoothed
with a self-levelling compound to give an even surface.
NOTE: The maximum permissible departure from a 2 m straight
edge, resting under its own weight on the subfloor is 3 mm. (SR1
Standard – BS 8204).

Prime subfloors with a dilute (1:4) SBR solution. For proprietary
subfloors refer to the manufacturer instructions.

Provided the subfloor is adequately prepared and clean, it may not be necessary to prime. This can vary depending tile adhesive selection. Please refer to the tile adhesive manufacturers instructions for priming information.

Ultralight should be installed using a flexible, cement-based adhesive. The adhesive should be trowelled out and combed through using a 6 mm x 6 mm (¼” x ¼”) square notch trowel to give a ribbed bed, any slight depressions in the subfloor being filled by the mortar.

NOTE: If you plan to apply a levelling compound over Ultralight
apply Warmup perimeter strip to the edge of the room to allow for
differential movement between the finished floor level and walls.

Ultralight should be laid on the freshly applied ribbed bed and
thoroughly bedded in to ensure that no voids are left beneath the
boards and they are solidly supported. All boards should be laid
with staggered joints.

NOTE: Allow the adhesive attaching the boards to the subfloor
to cure before laying electric underfloor heating directly onto the boards.

TECHNICAL SPECIFICATION

Product Code| WCI-16| Compressive Strength, 10% Compression, EN 826| 220 kPa
---|---|---|---
Pack Size| 16 Boards| Point Loading, tiled ANSI A118.| 12 ≥ 2.2 kN
Thickness| 6 mm| Robinsons test, 100 – 199 mm tiles, ASTM C627| Domestic
Dimensions| 800 mm (W) x 1200 mm (L| Robinsons test, 200 – 599 mm tiles, ASTM C627| Light Commercial
Area| 0.96m²| Robinsons test, ≥ 600 mm tiles, ASTM C627| Heavy Commercial
Weight of Board| 1.1kg| 7 Day Shear Strength, ANSI A118.12| 113 psi (780 kPa)
Thermal Resistance EN 12667| 0.111 m²K/W| Crack Resistance (Anti- Fracture / Decoupling), ANSI A118.12| ≥ 1/8″ => High Performance
Thermal Conductivity EN 12667| 0.054 W/mK| Long Term Water Absorption, EN 12087| 0.052% w/w
Reaction to Fire, EN 13501-1 EN ISO 11952-2| Euroclass E| Water Vapour Permeability, EN 12086| 9.12 mg/m²h
Release of Dangerous Substances, REACH| SVHC ≤ 0.1% w/w| Mould Growth, ANSI A118.12| Does not support mould growth

ACOUSTIC PERFORMANCE*

Floor Construction Standards Result Report No.

3/4” (19mm) OSB board

18” (450mm) Open Web Joists

3.5” (90mm) Fibreglass Insulation

1/2” (12.7mm) RC Deluxe Resilient Channel 5/8” (15.9mm) Gypsum Panel

| ISO 717-1

ISO 10140-2 ISO 10140-3 ASTM E90 ASTM E492

| Rw 54 dB

Ln,w 60 dB

STC 54

IIC 50

HIIC 50

| M5642.01- 113-11-R0

M5642.02- 113-11-R0

75 lb/ft² (350 kg/m²) Concrete Slab| ISO 717-1 ISO 10140-2 ISO 10140-3 ASTM E90 ASTM E492 ASTM 3222 ASTM E2179| Rw 53 dB Ln,w 67 dB ΔLn,w 11 dB STC 53 IIC 43 ΔIIC 15 HIIC 42 ΔIIC 14| M5643.01- 113-11-R0

M5643.02- 113-11-R0

WARRANTY

Subject to the conditions and limitations stated below, Warmup plc
(“Warmup”) warrants that Warmup Ultralight (“the product”) will
be free from manufacturing defects and will not deteriorate under
normal usage for a period of 10 years from the date of purchase
when installed and used in accordance with the product installation
guide.

THIS WARRANTY APPLIES:

Only if registered with Warmup within 30 days of purchase.
Registration can be completed online at www.warmup.co.uk. In the event of a claim, proof of purchase is required in the form of an invoice or receipt. Such invoice or receipt must indicate the purchase date of the product associated with the claim.

This warranty is void if the floor covering over the product has been lifted, replaced, repaired, or covered with subsequent layers of flooring.

The warranty period begins on the date of purchase. During the
period of the warranty Warmup will arrange for any sheet of the
product, that has been proven to be defective, to be either replaced
free of charge or issue a refund against the product only. These are the only remedies under this warranty, which does not affect your statutory rights. Such cost does not extend to any cost other than direct cost of replacement by Warmup and does not extend to costs of relaying, replacing, or repairing any floor covering or floor.
WARMUP PLC SHALL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO EXTRA UTILITY EXPENSES OR DAMAGES TO PROPERTY.

WARMUP PLC IS NOT RESPONSIBLE FOR:

  1. Damage or repairs required because of faulty installation or
    improper application.

  2. Damage because of floods, fires, winds, lightening, accidents,
    corrosive atmosphere or other conditions beyond the control of
    Warmup plc.

  3. Use of components or accessories not compatible with the product.

  4. Products installed outside of any country or territory within which Warmup operates.

  5. Products not supplied or designated by Warmup.

  6. Damage or repairs required because of any improper use.

  7. Changes in the appearance of the product that does not affect its
    performance.

Warmup plc
www.warmup.co.uk
uk@warmup.com
Tel: 0345 345 2288
Fax: 0345 345 2299

The WARMUP word and associated logos are trade marks. © Warmup Plc. 2022 – Regd.™ Nos. 1257724, 4409934, 4409926,
5265707. E & OE.

Warmup plc n 704 Tudor Estate n Abbey Road n London n NW10 7UW n UK

Warmup GmbH n Ottostraße 3 n 27793 Wildeshausen n DE

Warmup – IM – Ultralight – V1.6 2022-11-07_EN

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals