OMRON S8BA Integrated Battery Instruction Manual

June 9, 2024
Omron

OMRON logo

OMRON S8BA Integrated Battery

OMRON S8BA Integrated Battery

Thank you for purchasing Omron’s Uninterruptible Power Supply (UPS).
Be sure to read this document and User’s Manual for safe use.
Be sure to store this document and User’s Manual carefully so that it can be referred to at any time when necessary.
User’s Manual catalog number: U726[EN]

Name of each part

OMRON S8BA Integrated Battery 1

  1. DC input terminal block
  2. DC output terminal block
  3. Battery connection terminal block
  4. LED indicators
  5. CONTACT port
  6. Battery communication port
  7. Mode selection / Backup time setting switch
  8. RS232C/USB port

List of connectable cable

OMRON S8BA Integrated Battery 3

  1. Solid wire
  2. Stranded wire

Correct positions

OMRON S8BA Integrated Battery 2

  • Leave at least 50 mm between the upper and lower.
  • When installing devices other than the UPS on the left or right side of the UPS, maintain a clearance of at least 15 mm.

FCC

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.

ICES
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Safety Precautions

Important information for safe operation is described.
Be sure to read it before installation and start of use.

Meanings of Signal Words

Warning Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death.
Additionally there may be significant property damage.

Caution Indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury or property damage.

Meaning of graphical symbols

  • General inhibition
    Notice prohibiting an unspecified general action.

  • General instruction
    Notice instructing an unspecified general action.

  • Do-not-disassemble prohibition
    Notice prohibiting disassembly because disassembling the device may cause such an accident as an electric shock.

  • Prohibition of use in locations subject to water such as a bathroom and shower room.
    Notice prohibiting installation of the device in locations subject to water, because if a device not made water-proof is used in such locations, injury may occur due to an electric leak.

  • Do-not-touch prohibition
    Notice prohibiting touching the device because touching a certain part of the device under certain conditions may result in injury.

  • Explosion alert
    Notice alerting the user to the possibility of explosion under certain conditions.

Note that events categorized as a caution required matter also may cause more serious results under certain conditions.
The information described here is very important and must be strictly observed.

Alert Statements in this Manual

Warning

  • Provide safety measures in external circuits, not in the UPS, in order to ensure safety in the system if an abnormality occurs due to malfunction of the UPS or another external factor affecting the UPS operation. Not doing so may result in serious accidents.
  • Do not short between the connector terminals.
  • Dispose of or collect (recycle) the battery unit according to your own rules set for that purpose or as instructed by laws and regulations.

Installation and connection

Caution

  • Be aware of the weight and balance when carrying the unit, and install on a stable and sturdy base.
  • Keep plastic package bags out of reach of children.
  • Be sure to connect the input power supply of the unit to a DC power supply device having a rated voltage (24 VDC), or a battery power feed system.
  • When an abnormality (unusual sound or smell) occurs, turn OFF the unit’s “Power” switch to stop the output, and stop the supply of commercial power.
  • To use this product as a CE marking compliant device, use a 2m or shorter connection cable.
  • When installing the input cable, make sure to perform the connection as specified. Make sure to stop the primary power supply before connecting the unit to the input power supply terminal.
  • Do not connect any devices other than rated voltage is DC24V.
  • Do not install the unit in other than specified orientations.
  • Do not use the unit at a location where the operating environment temperature is more than 55°C.
  • Do not exceed the ranges specified for environmental conditions during use/storage.
  • When you use plug strip and other plugs to connect additional devices, do not connect devices that exceed the current capacity of the available plugs.
  • Do not use a cable with a damaged jacket.
  • Do not pinch or sharply bend the cable. Do not fold or knot the cable.
  • All of the included accessories are designed to be used with the unit. Do not use the accessories with other devices.
  • Do not block the air vents (upper and lower).
  • Do not drop the battery unit or subject it to intense shock. Risk of injury and fire if the unit is dropped.
  • Do not connect the RS232C/USB port or the CONTACT port to a LAN device.
  • Do not remove the dust cover for ports that are not in use (RS232C, CONTACT).
  • Do not run the unit in series or in parallel.
  • Do not disassemble, repair, or modify the unit.

Use

Caution

  • When the battery unit is dead, replace it immediately or stop using the unit.
  • Occasionally, wipe off dust on the input terminal block and the output terminal block with a dry cloth.
  • If you notice something unusual such as abnormal sound or smell, discoloration, deformation, and heating, turn OFF the unit’s “Power” switch to stop the output and stop the supply from the “input power supply”.
  • The unit is equipped with an output circuit that can supply power to the connected devices even if the unit stops due to a failure or mis-operation of the internal circuit function. If you want to stop the output, stop the source of the “input power supply”.
  • When charging the battery, if the battery cannot be charged completely even after the predetermined charging time, turn OFF the “Power” switch of the unit to stop charging the battery.
  • Do not use the unit in a closed place and do not cover the unit.
  • Do not place any objects on the unit, and do not drop heavy objects onto the unit.
  • Do not allow the unit to come in contact with water. If you drop the unit, stop using it.
  • If fluid leaks from the interior, do not touch the fluid.

Maintenance

Caution

  • When maintaining the connected equipment, turn OFF the unit’s “Power” switch to stop the output, and stop the supply of the “input power supply”.
  • Do not disassemble, repair, or modify the unit.
  • If fluid leaks from the interior, do not touch the fluid.
  • Do not throw the unit into fire.
  • Do not insert metal objects into the input terminal block and the output terminal block of the UPS.
  • Do not insert metal objects into the battery connectors.

For battery replacement

Caution

  • Do not use other than the designated battery unit.
  • Do not replace the battery unit in a place where there is flammable gas.
  • Do not disassemble or modify the battery unit.
  • Do not drop the battery unit and do not expose it to strong impact.
  • Do not short the battery unit with metal objects.
  • Do not dispose of battery units in a fire.
  • If fluid leaks from the battery unit, do not touch the fluid.

Compliance
Do not perform withstand voltage testing or insulation resistance testing.
A surge absorbing element is incorporated, and may be destroyed.

Precautions for Safe Use

Before using

  • The battery has not been charged at the time of purchase. Be sure to charge it before use. Connect this unit to the input power supply to charge the battery unit.
  • When moving the unit from a cold place to a warm place, leave it for several hours before using it.
  • Take measures for handling unforeseen accidents, such as data backup and system redundancy.

Connecting

  • Do not short (ground) the output lines of the unit and the battery connection cable.
  • In the event you transfer or sell this unit to a third party, please include all of the documentation that came with the unit. This is to ensure that the unit is used in line with the conditions described in the included documentation.

Using

  • Before stopping the commercial power to the unit, turn OFF the “Power” switch of the unit.
  • Do not use for an application that frequently requires Battery Mode.
  • If you want the UPS to stand by in a UPS startup state, set 3 months or less for the input power supply stop period.

Storing

  • Storing the battery in UPS for a long term, store at an environment less than 25°C and recharge 15 to 30 minutes the battery within 1 year.
  • Do not install or store the unit in a place exposed to direct sunlight.

Terms and Conditions Agreement

Our product” is designed and manufactured as a general purpose product for use with a general industrial product. It is therefore not intended for the purposes listed below. Should you use “our product” for any of such purposes, we shall not guarantee “our product”. Even for any of such purposes, however, the above is not applicable to cases in which our product is intended for the use with a special product “we” intend and special agreement exists.

  • When a high level of safety is required (such as nuclear control equipment, combustion equipment, aerospace equipment, railway equipment, elevating equipment, entertainment equipment, medical equipment, safety device, and other use that can cause danger to the life or body of a person)
  • When a high level of reliability is required (such as a gas, water, or electricity supply system, 24-hour non-stop operation system, payment system, and other use that handles rights and properties)
  • When the use conditions or environment is severe (such as equipment installed outdoors, equipment susceptible to chemical contamination, equipment susceptible to electromagnetic interference, and equipment susceptible to vibration and impact)
  • When the use conditions or environment is not as written in the “catalog or other documents”

Besides the purposes described from (a) to (d) above, “the product described in this catalog or other documents” is not intended for vehicles (including two-wheel vehicles, and the same applies hereafter). Do not install this product in a vehicle.

For products to be installed in vehicles, consult with our sales personnel. ※The above is part of the conditions for application.
Before using this product, carefully read the content of Disclaimer of Warranty described in Omron’s latest catalogs and manuals such as Best Catalogs, General Catalogs, and data sheets.

Conformance to EU Directives and UK Legislations

  • This product must be installed within a control panel.
  • You must use reinforced insulation or double insulation for the DC power supply connected to this product.
  • Models of this product that comply with EC Directives also conform to the Common Emission Standard. Radiated emission characteristics (10-m regulations), in particular, may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. Therefore, even when using a model of this product that complies with EC Directives, you must confirm and ensure the compliance to EC Directives of the entire machine or equipment.
  • This is a Class A product (for industrial environments). In a residential environment, it may cause radio interference. If radio interference occurs, the user may be required to take appropriate measures.

Conformance to UL

  • This product must be installed within a control panel with an internal heater or other unit to protect against the formation of condensation.
  • Gaps in the door to the control panel must be completely filled or covered with gaskets or other material.
  • For use in Pollution Degree 2 Environment.
  • Make sure to connect the device with Class 2 output to the USB port.

Europe/Middle East Asia/Africa/Russia
OMRON Europe B.V.
Wegalaan 67-69, 2132 JD Hoofddorp, The Netherlands
Phone: 31-23-56-81-300
Fax: 31-23-56-81-388
Web site: http://industrial.omron.eu/

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals