NOTE: RED wire has priority over wire when both wires are activated.

Operation

This lighthead is designed with 2 sets of memory to allow instant switch between 2 pre-set flash patterns with a simple switch of a button (user- supplied). Connect BLACK wire to Ground, and apply +VDC to WHITE wire to activate Memory1 or to RED wire to activate Memory2.

Step 1

Select Function & Flash Pattern

a. Activate Memory1 by applying +VDC to wire.
b. While wire is activated, momentarily apply +VDC to YELLOW wire:

  • once for <1 second for next flash pattern.
  • quickly three times for reset to default.

cell2 ID6 Surface Mount - Select Function

Step 2 Select Mode

a. While wire is activated, apply +VDC to YELLOW wire for >3 seconds to enter Mode setting.
b. Once in Mode setting, lighthead will display dim slow pulses based on its Mode and Group (single or double pulses respectively).
c. Momentarily apply +VDC to YELLOW wire for <1 second for next Mode. (refer to Mode charts).
d. Momentarily apply +VDC to YELLOW wire quickly 3 times within 1 second to reset to Mode1.
e. When desired mode is selected, apply +VDC to YELLOW for >3 seconds or disconnect all power to exit Mode setting.
f. To configure Memory2, apply +VDC to RED wire and repeat the above steps A & B.

NOTE: For mutiple lighthead installation, heads in the same Group flash together. [G1] Heads alternate with [G2] Heads. For synchronization all YELLOW wires must be connected together, and set at the same Flash Pattern.

| Mode| Warning Effect
---|---|---
1| All (single pulse)| All [G1]
2| All (double pulse)| All [G2]
3| Split (single pulse)| Split [G1]
4| Split (double pulse)| Split [G2]
5| Left (single pulse)| Left only [G1]
6| Left (double pulse)| Left only [G2]
7| Right (single pulse)| Right only [G1]
8| Right (double pulse)| Right only [G2]

All = Left & Right simultaneous
Split = Left & Right alternating
[G1] = Group1 [G2] = Group2

| Mode| Steady &Warning Effect
---|---|---
1| All (single pulse)| Left Steady & Right Double Flash [G1]
2| All (double pulse)| Left Steady & Right Double Flash [G2]
3| Split (single pulse)| Right Steady & Left Double Flash [G1]
4| Split (double pulse)| Right Steady & Left Double Flash [G2]
5| Left (single pulse)| Left Steady & Right Quad Flash [G1]
6| Left (double pulse)| Left Steady & Right Quad Flash [G2]
7| Right (single pulse)| Right Steady & Left Quad Flash [G1]
8| Right (double pulse)| Right Steady & Left Quad Flash [G2]

All = Left & Right simultaneous
Split = Left & Right alternating
[G1] = Group1 [G2] = Group2

| Mode| Full Steady Effect
---|---|---
1| All (single pulse)| All high power
2| All (double pulse)| All low power
3| Split (single pulse)| All high power
4| Split (double pulse)| All low power
5| Left (single pulse)| Left high power
6| Left (double pulse)| Left low power
7| Right (single pulse)| Right high power
8| Right (double pulse)| Right low power

All = Left & Right simultaneous
Split = Left & Right alternating

Examples
Example Configuration#1:
I would like Memory1 to be Full Steady (All low power), and Memory2 to be split Ultra flash (Left row LEDs alternate Right row LEDs).

  1. Activate wire and select FP#15.
  2. Enter Mode setting and select Mode#2.
  3. Activate RED wire and select FP#11.
  4. Enter Mode setting and select Mode#3 (or Mode#4).

cell2 ID6 Surface Mount - Right row

Example Configuration#2:
I would like Memory1 to be Left Steady & Right Double Flash, and Memory2 to be All Ultra flash.

  1. Activate wire and select FP#14.
  2. Enter Mode setting and select Mode#1 (or Mode#2).
  3. Activate RED wire and select FP#11.
  4. Enter Mode setting and select Mode#1 (or Mode#2).

cell2 ID6 Surface Mount - Double Flash

**Quick reference chart

**

cell2 ID6 Surface Mount - TABILE

Documents / Resources

| cell2 ID6 Surface Mount [pdf] Instruction Manual
ID6 Surface Mount, ID6, Surface Mount, Mount
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals