ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower Owner’s Manual

June 9, 2024
ATRIX

ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING APPLIANCE

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY:

  1. Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
  2. Electrical shock may occur if used outdoors or on wet surfaces.
  3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
  4. Use only as described in this manual. Use only the manufacturer™s recommended instructions.
  5. Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return to Atrix International.
  6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges of corners. Do not run appliance over cord. Keep cord away from heated surfaces.
  7. Do not unplug by pulling on cord. To unplug, grasp plug, not the cord.
  8. Do not handle plug or appliance with wet hands.
  9. Do not put any object into any openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
  10. Keep hair, loose clothing, fingers and all body parts away from openings and moving parts.
  11. Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
  12. Do not use without filter in place.
  13. Turn off all controls before unplugging.
  14. Use extra care when cleaning on stairs.
  15. Do not use to pick up any liquids, including flammable or combustible liquids such as gasoline or use in areas where they may be present.
  16. Connect to a properly grounded outlet only.
  17. This appliance is not intended for use by persons (including children) with reduced physical, sensory and mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of appliance by person responsible for their safety.
  18. Children should be supervised to ensure that they do not play with the appliance.

SAVE THESE INTRUCTIONS!

GET TO KNOW YOUR ERGO EDGE WALL MOUNT VACUUM

ATRIX VACBP1WV Ergo Edge
Wall Mount Vacuum or Blower FIG- \(1\)

  1. Main Unit
  2. Exhaust Filter Cover
  3. On/Off Power Switch
  4. Latch
  5. 30′ Stretch Hose
  6. Telescopic Tube
  7. Variable Suction Control
  8. Hose and Tool Caddy Hanger
  9. Hose Inlet
  10. Canister Lid
  11. Wall Bracket
  12. Vacuum Bracket Set (2 piece)
  13. Tool Caddy
  14. Hardware Kit (four (4) Vac Screws, six (6) Wall Screws and Anchors)
  15. Telescopic Tube Button
  16. Hard Floor Brush
  17. Air Driven Turbo Brush
  18. Round Dusting Brush
  19. Extraction Tool
  20. Crevice Tool
  21. Blowing Port
  22. Blowing Attachments
  23. Exhaust Filter (not shown)
  24. HEPA Dust Bag
  25. Shake-Out Bag (not shown)
  26. HXEPA Pre-Motor Filter (not Shown)

See Ergo Edge Wall Mount Installation Instructions

OPERATING INSTRUCTIONS

Warning : To reduce the risk of electric shock, the power cord must be disconnected before removing the dust bag, shake-out bag, changing the filters or performing maintenance or trouble-shooting checks.

Assembling Your Vacuum Cleaner – Note: Always remove the power plug from the wall outlet before attaching or removing accessories.
Important : Do NOT use the vacuum without all filters, shake-out bag, and HEPA dust bag in place.

  1. Unplug the power cord and remove the flexible hose.
  2. To open the canister lid, press on the canister lid tabs on each side of the unit and lift canister lid. (Fig. 1)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(2\)
  3. Pull the tab on the HEPA dust bag holder out slightly and flip upwards. (Fig. 2)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(3\)
  4. Holding the HEPA dust bag in your hand, slide it firmly between the slots in the bag holder. (Fig. 2)
  5. The cardboard face to the new bag should rest securely in the dust bag cover guidelines. (Fig. 3)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(4\)
  6. Ensure that the shake-out bag is in place. (Fig. 4)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(5\)
  7. Flip the HEPA bag holder over, pressing the tab on the bag holder until it clicks, then replace the canister lid.
  8. The canister lid can be replaced on the unit with the hose opening on the right or left, as per your preference. (Fig. 5)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(6\)

Attaching the Telescopic Tube to the Flexible Hose Handle

  1. Holding the telescopic tube, insert the handle into the telescopic tube receptacle. Push the handle in. (Fig.6)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(7\)
  2.  Push forward on the plastic button and pull the inner tubeoutward to extend for a longer reach. (Fig. 7)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(8\)
  3. To remove the telescopic tube from the flexible hose, pull on the telescopic tube and flexible hose handle to pull it out.

Manual Suction Control

Your vacuum cleaner includes a manual variable suction control on the flexible hose handle. The suction power can be adjusted by moving the suction regulator to the desired position between open and closed. (Fig. 8) Open gives you less suction, closed maximum suction. For example, less suction is required on upholstery and draperies compared to thick carpets, which require maximum suctionATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG-
\(9\)

Using the Attachments

Air Driven Turbo Brush

The efficiency of your air driven turbo brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this. In order to ensure that maximum air suction is maintained, please read the following instructions:

  1. Change the HEPA dust bag or empty the shake-out bag frequently.
  2. Replace the pre-motor and exhaust filters as needed.
  3. Ensure that the rotating brush is kept free of hair and string, which may accumulate and decrease brush performance.
  4. To attach the air driven turbo brush, insert the telescopic tube into the air driven turbo brush.
  5. To adjust the suction control on the air driven turbo brush, slide the suction control for more or less as desired.

Blower Attachments

The blower attachments can be used with the vacuum to pick up very fine dirt particles in tight crevices or spots, or to inflate inflatable items or air mattresses. The blower attachments have air bleed holes. These air bleed holes help relieve some air pressure so that the attachment does not blow off. However, should an increase in air pressure be desired, simply cover one or more of the air bleed holes.

  1. Pull up and hold the exhaust tab, with the free hand pull out the exhaust filter cover grill. (Fig. 9)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(10\)
  2. Remove the exhaust filter.
  3. To place the power port into the exhaust outlet, align the lower tabs on the blower port with the slots on the exhaust. Pull up on the exhaust tab and push the tab and push the top of the blower port until it snaps into place.
  4. To attach the hose to the blower port, align the flexible hose and turn counter-clockwise until it stops. The hose is now securely in place. (Fig. 10)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(11\)
  5. To blow up inflatable items, select the appropriate size blower attachment that will fit into the air valve.
  6. Turn the unit on and hold the blower attachment and air valve while the vacuum exhaust is pumping air into the inflatable.
  7. To detach the flexible hose, turn clockwise and pull out from blower port

Using the Blower Attachments

The blower attachments are extremely useful for vacuuming in hard to reach crevices and small compartments such as in cars.
Important Note : When blocking the air holes. Grasp the blower attachment firmly so that they do not blow off.
Do not use blower function to clear dust of fragile or delicateobjects unless they are secured or held firmly in place as the blower action is quite strong and may cause damage

Using Your Vacuum

  1. Insert the power plug into the wall outlet.
  2. Connect the hose, and telescopic tube if desired.
  3. Turn the unit on by pressing the switch located near the base of the unit to turn the vacuum cleaner on

Warning: To reduce the risk of electric shock, the power cord must be disconnected before removing the dust bag, shake-out bag, changing the filters or performing maintenance or trouble-shooting checks.

Removing & Replacing HEPA Dust Bag

Important Note : DO NOT use the vacuum without all filters, shake-out bag, and with or without HEPA dust bag in place

  1. To remove the HEPA dust bag, press on the canister lid tabs on each side of the unit and lift canister lid. (Fig. 11)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(13\)
  2. Pull the tab on the HEPA dust bag holder out slightly and flip upwards.
  3. Hold the HEPA dust bag in your hand, slide it out from the slots in the bag holder. Hold carefully to avoid having dust fall out of the HEPA dust bag. (Fig. 12)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(14\)
  4. Replace the HEPA dust bag with a new bag. Do not reuse the same bag.
  5. The cardboard face of the new bag should rest securely in the dust bag cover guides. (Fig. 13)ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(15\)

Cleaning & Replacing the Shake-Out Bag

Note : Clean the shake-out bag outdoors when changing the HEPA dust bag.
Optimum performance is achieved by using the HEPA dust bag with the shakeout bag decreasing the need for washing the shake-out bag.

Cleaning & Replacing when used with the HEPA Dust Bag:

  1. Replace the shake-out bag, holding the handle at the bottom of the bag, shake outdoors vigorously over a garbage receptacle until there is no more dust.
  2. Inspect shake-out bag regularly for tears or damage. Replace shake-out bags if damage or tears are present.

Cleaning the Shake-Out Bag:

  1. Remove the shake-out bag, shake vigorously outdoors or over your trash bin until there is no more dust.
  2. The shake-out bag is hand washable in lukewarm water.
  3. Allow to air dry for 24 hours. The shake-out bag should be replaced when needed. Never replace into the vacuum if still wet.
  4. Replace clean shake-out bag in unit and replace the canister lid onto the vacuum

Cleaning the HEPA Pre-Motor Filter

Important – Please Note: The HEPA pre-motor filter will stop most dust particles and airborne allergens from re-entering the air you breathe. The HEPA pre-motor filter will accumulate many fine dust particles that are difficult to see. Be assured that the HEPA pre-motor filter is doing the job. Clean or replace the HEPA pre-motor filter from time to time, when it is visibly dirty or if you notice reduced suction, as described in this section.

  1. Remove the shake-out bag from the canister. The HEPA pre-motor filter is located underneath the shake-out bag. Pull up near the tabs on the sides of the HEPA filter. This is a press fit system.
  2. Vigorously “Tap Clean” the HEPA pre-motor filter on a hard surface to remove any residual dust that might still be on the HEPA pre-motor filter.
  3. You can wash the HEPA pre-motor filter by running it under the tap and allowing the water to run on the dirty side at least once a month or when suction appears to be decreased.ATRIX VACBP1WV Ergo Edge Wall Mount Vacuum or Blower FIG- \(16\)

WARRANTY INFORMATION

Warranty/Service Information: For warranty service information, please contact Atrix or your local Atrix distributor.

Atrix Ergo Edge Wall Mount Vacuum/Blower Limited Warranty: To the original user purchasing the Atrix Ergo Edge Wall Mount Vacuum/Blower, Atrix warrants that the vacuum will be free of defects in material and manufacture for a period of one (1) year from the date of purchase. Should any failure to conform to this warranty appear within this period, Atrix will, at its option, repair or replace the defective product. It is the user’s responsibility to return the product, freight prepaid, to Atrix International. These remedies are the user’s exclusive remedies for breach of this warranty.
Exclusions to warranty coverage: The above warranty will not apply to any special configurations or to any unit that have been modified, or damaged by negligence, misuse, accident or failure to follow Atrix’s Instruction manual. Consumable supplies, such as filters, accessories, and motor brushes are not covered by this warranty.
Disclaimer of Warranty: EXCEPT FOR THE IMPLIED WARRANTIES OF TITLE AND AGAINST PATENT INFRINGEMENT, ATRIX MAKES NO OTHER WARRANTIES WITH RESPECT TO THE ATRIX BACKPACK VACUUM CLEANER, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Limitation of Liability :

ATRIX WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY COINCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGES OR ECONOMICAL LOSS, BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY IN TORT OR ANY OTHER LEGAL THEORY, EVEN IF ATRIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES INCLUDING, BUT NOT LIMITED TO LOSS OF PROFITS, REVENUE, EQUIPMENT USE, DATA OR INFORMATION OF ANY KIND. THE LIABILITY OF ATRIX SHALL NOT UNDER ANY CIRCUMSTANCE, EXCEPT AS EXPRESSLY PROVIDED HEREIN, EXCEED THE PRICE OF THE ATRIX BACKPACK VACUUM.

To Register your Warranty Visit:
www.atrix.com

Ergo Edge Wall Mount Installation InstructionsATRIX VACBP1WV Ergo Edge
Wall Mount Vacuum or Blower FIG- \(17\)

  1. Step 1

  2. Locate an area to hang the wall bracket and mark your 4 holes using the bracket as your guide.

  3. Step 2

  4. Install the wall bracket using 4 of the 1-1/2” screws. Use plastic anchors as well for drywall.

  5. Step 3

  6. Locate an area close to the vacuum to hang the hose and tool caddy hanger (preferably on the same side as your hose) and mark your 2 holes using the hanger as your guide. The center distance between the two holes should be about 2-5/8”.
    Please note : the vacuum hose can be oriented either left or right of the vacuum by removing the vacuum lid and turning the lid 180 degrees.
    Once installed, the vacuum should look like the below image:

  7. Step 4

  8. Install the hose and tool caddy hanger on the same side as your hose using 2 of the 1-1/2” screws. Use plastic anchors as well for drywall.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals