OVERVIEW
1 | Display | Shows the desk height and other additional functions |
---|---|---|
2 | Up | Adjustment of the desk height upwards |
3 | Down | Adjustment of the desk height downwards |
4 | Preset 1/2/3 | Desk height adjustment to one of three positions saved by the |
user
5| Lock/Presets| Unlock/Lock the control panel and save presets
6| Timer| Setting the prompt to change the working position
USING THE CONTROL PANEL
Plug the end of the control panel cable into the input port on the desk.
Control panel lock
If you wish to prevent changes to the settings, hold down the M butt-on for
3 seconds to leck the control panel. The control panel lock is active when the
display shows —.
The control panel lock can also be activated automatically after 1 minute –
see “Control panel lock settings” below in the manual. Press and hold the M
for 3 seconds to unlock the control panel. The display shows the current
height of the desk.
Note: After 1 minute of inactivity, the control panel lock automati- cally
activates.
Setting the height of the desk
To change the height of the desk press and hold the button up or down until
the desk reaches the desired height.
Presets
Press the button M to save the height in one of the presets. The S- on the
display starts flashing. While the S- flashes, press one of the buttons 1, 2
or 3. Each of the preset buttons allows you to save one user-defined height.
Press the corresponding button to recall saved height preset.
Note: You can stop any movement of the desk top by pressing any button
(except the T button).
Reset
If you are using the control panel for the first time, or if you have not
used it for a long time, we recommend that you reset the system before using
it again.
To reset, press the buttons up and down in the same time. An alert sounds and
the display shows -57. The desk top lowers to the lowest possible height and
then rises a little. The display shows the current height of the desk. An
alert sounds and the reset process is successfully completed. Never release
the buttons until the se- cond alert sounds.
Timer
The timer notifies the user to change the working position.
Press the button T to set the timer. The display shows “0.5”. Press repeatedly
the button T to set the required timer time from 30 minutes to 2 hours. Each
press of the button T extends the timer by 30 minutes. When the setting is
completed, the display flashes for a few seconds, and when the desk height is
displayed, the set time is saved and the countdown starts. An icon showing
the timer setting appears in the upper corner of the screen.
When the set time has elapsed, an alert sounds five times.
If you want to cancel the times, press repeated the T button, until the
display shows the height of the desk and the timer icon disappears from the
display.
Unit change
The display of the units on the control panel display is preset to
centimeters.
Press and hold the T button for 3 seconds to change the units. The unit
changes to inch. Repeat the procedure to change the units back to centimeters.
Power save mode
The control panel automatically switches to power save mode after 10
minutes of inactivity. The display turns off.
Press any button to wake.
SETTINGS
Setting | Description | Factory default | Values range |
---|---|---|---|
Setting the minimum desk height | 62 cm | 62-118 cm | |
Setting the maximum desk height | 72 cm | 72-128 cm | |
Adjust the sensitivity of the anti-collision sensor when the board moves | |||
upwards | 4 | 0 up to 8 | |
Adjust the sensitivity of the anti-collision sensor when the board moves | |||
down | 4 | 0 up to 8 | |
Setting the sensitivity of the gyroscopic sensor | 4 | 0 up to 8 | |
Adjusting the thickness of the desk top for correct display of the desk | |||
height | 0.0 | 0 up to 5 cm | |
Control panel automatic lock setting | 0 | 0 (off) 1 (on) |
Procedure to change settings
- Toenter the settings, press and hold the M and T button simultaneously for 5 seconds until an alarm sounds and $-1 starts flashing on the display.
- Select the reuired setting (S-1 to S-7) using the buttons up and down and confirm by pressing the M button.
- The display shows the factory settings and using the up and down buttons set the required value of the setting.
- To save the setting press the M button. The display shows X-S if saved successfully and X-F if unsuccessful.
- You can exit the settings at any time using the T button or wait 8 seconds until the display shows the height of the desk.
Note: The setting ends automatically after 10 seconds of inactivity.
The desk height shown does not include the thickness of the tabletop.
TROUBLESHOOTING
Message | Description | Solution |
---|---|---|
The automatic control panel lock is active. | Hold the M button for 3 |
seconds.
| The system requires a reset.| Reset.
| The system has diagnosed an unspecified electronic error.| Disconnect the
desk from the power supply and then reconnect.
| Different leg heights| Reset.
| Control panel connection error| Disconnect the desk from the power supply
and check the control panel connection.
| The system detected a collision.| Remove all objects impeding movement.
| The system has diagnosed an unspecified electronic error.| Disconnect the
desk from the power supply and then reco- nnect. If the problem persists,
replace the control box.
| The system detected a collision.| Remove all objects impeding movement.
The control panel is not placed/connected correctly.| Make sure that the
control panel is properly connected ac- cording to the instructions in this
manual or that it is placed ona flat surface.
The control panel cable end has been pulled out.| Plug in the end of the
control panel cable and make sure that it cannot be easily pulled out.
| Motor connection error| Check connections or replace cables. E11 corresponds
to cable M1, E21 corresponds to cable M2.
| The system has diagnosed an unspecified electronic error.| Disconnect the
desk from the power supply and then reco- nnect. If the problem persists,
replace the control box.
| Defective motor cable| Check connections or replace cables. E13 corresponds
to cable M1, E23 corresponds to cable M2.
| Defective distribution cables| Check connections or replace cables. E14
corresponds to cable M1, E24 corresponds to cable M2.
| Short-circuit| Replace motor. E15 corresponds to cable M1, E25 corre- sponds
to cable M2.
| The desk top is too laden and the motor does not manage the weight of the
top.| Remove items from the desk top and try again.
Always remove all heavy objects from the desk top before adjusting it.
| The desk top is moving in the wrong direction.| Check connections or replace
cables. E17 corresponds to cable M1, E27 corresponds to cable M2.
| Desk overload| Remove items from the desk top and try again.
Always remove all heavy objects from the desk top before adjusting it.
| Memory error| Disconnect the desk from the power supply and then reconnect.
If the problem persists, replace the control box.
| Anti-collision system sensors error| Replace the control box.
| System overheating| Allow the system to cool. Do not change the desk height
for about 18 minutes.
www.alzaergo.com
Co. Reg. No. 27082440
Alza.cz a.s., Jankovcova 1522/53, 170 00 Prague 7, Czech Republic
© 2022 Alza.cz a.s. All Rights Reserved.
Documents / Resources
| alza
ergo APW-EGET8100 Control
Panel
[pdf] User Manual
APW-EGET8100 Control Panel, APW-EGET8100, Control Panel
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>