Features

Output: Constant Voltage
Range: 110-277VAC
PFC design: Built-in active PFC function
Efficiency: Up to 91%
Protections: Short circuit/ over load/ over temperature
Heat dissipation: Cooling by free air convection
Waterproof performance: For dry, damp & wet location (24V); For dry & damp location (48V)
Dimming function: Phase dimming: work with Forward phase, MLV and Reverse phase, ELV, TRIAC dimmers.
0-10V dimming: 0-10V/1-10V/Potentiometer/10V PWM 4 in 1
Dimming range: 0-100%
Application: Suitable for the application of LED lighting
Warranty: 5 years warranty
Others: PWM output, High power factor PF≥0.95, flicker-free dimming

Specification

Model KVG-C24384-DWJ KVG-C48384-DWJ
Certificate UL / cUL / FCC / Class 2 / CE / Class P / SELV / RoHS /

REACH
Output| DC Voltage| 24V| 48V
Voltage Tolerance| ±0.5V
Voltage Regulation| ±0.5%
Rated current| 44A| 42A
Rated power| 384W (496W)
Load Regulation| ±1%
Input| Voltage Range| 110-277VAC
Frequency Range| 47 – 63Hz
Power Factor (Typ.)@ full load| 0.99@120VAC     0.99@277VAC| 0.95@120VAC 0.93@277VAC
THD(Typ. ) @ full load| <20%
Efficiency(Typ.) @ full load| 88%@120VAC     91%@277VAC| 87%@120VAC 89%@277VAC
AC Current (Max.)| 4.1A@100VAC
Inrush Current (Typ.)| 30A,1.2ms @50%Ipeak
Leakage current| <0.5mA
Protection| Short Circuit| Shut down o/p voltage, re-power on to recover after fault condition is removed
Over Load| ≤120% Hiccup mode, recovers automatically after fault condition is removed
Over temperature| Shell surface temp.100℃±10℃ shut down o/p voltage, automatically recover after cooling
Environment| Working TEMP.| -40~+60℃ (see below derating curve)
Working Humidity| 20 – 95%RH non-condensing
Storage TEM.,Humidity| -40 – +80℃,10 – 95% RH non-condensing
TEMP.coefficient| ±0.03%/℃(0 – 50℃)
Vibration| 10~500Hz, 5G 12min./1 cycle, period for 72min. each along X,Y,Z axes
Safety & EMC| Safety standards| UL8750     CAN/CSA-C22.2 No.250.13(US)
Withstand voltage| I/P-O/P:1.8KVAC      I/P-FG:1.8KVAC      O/P-FG:1.8KVAC (US)
Isolation resistance| I/P-O/P: 100MΩ / 500VDC / 25℃ / 70% RH
EMC Emission| FCC 47 CFR Part 15, Subpart B(US)
Others| Net Weight| 2.85Kg
Dimension| 323
140.451.8mm (LWH)
Packing| 380
305*160mm      5 pcs/CTN      15.28KG/CTN
Notes|

  1. All parameters NOT specially mentioned are measured at 120VAC input,rated load and 25℃of ambient temperature.
  2. Tolerance: includes set up tolerance and load regulation .

Efficiency Curve (efficiency vs output load)

Efficiency Curve

Derating Curve (output load vs TEMP.)

Derating Curve

  • To extend their life, please refer to the Derating Curve and derate according to the temperature.

Power Factor Curve

Power Factor Curve

Mechanical Specification

Mechanical Specification

24V & 48V Version

  1. Input wire 18AWG, Black and White to be connected to AC L and N,Green wire is ground wire and goes ground.
  2. Output wire 4*16AWG, Red to LED Positive side (+), Black to LED Negative side (-).
  3. Dimming cable 4*18AWG, DIM (+) Purple to 0/1-10V dimmer signal (+), DIM (-) Grey to 0/1-10V dimmer signal (-).
  4. Please DO NOT connect “DIM-“ to “LED-“, “DIM+” to “ LED+”, or other incorrect connection.
  5. Please make sure you connect these correctly otherwise your product will not function correctly and could be damaged.

Warm tips:

  1. 1. Recommended Max. Carrying Current (A) = wire diameter(mm²) x 10A/mm ²
    For example: 1mm ² output cable, Recommended Max. Carrying Current (A) = 1mm ² x 10A/mm ²=10A

  2. Any other requests for, we can customized.

Dimming Operation and Connecting Diagram

  • Using two ways of dimming at the same time, you must be assured that LED lighting is up to the max. Brightness then you could operate with the other dimming;
    Dimming Operation and Connecting Diagram

  • Using one dimming —TRIAC/Phase cut dimming

1. The Pulse-Width Modulation (PWM) of output voltage can be adjusted through input terminal of the AC phase line(L) by connection a phase /Triac dimmer or lighting system.
2. Working with forward phase, MLV and Reverse phase, ELV, TRIAC dimmers or light system.
3. Min. loading is about 10%.
4. Please try to use dimmers with power at least 2 times as the output power of the driver.  

Dimming Operation and Connecting Diagram

  • Using one dimming —0-10/ 1-10V/ 10V PWM/ Potentiometer dimming
    Dimming Operation and Connecting Diagram
    Dimming Operation and Connecting Diagram

Instruction

  1. This driver should be installed by qualified and professional person.
  2. Please make sure the driver is installed with adequate ventilation around it to allow for heat dissipation; If the product is installed in a sealed lamp, it is recommended to reduce the load and use it; The recommended load size is ≤ 80% of the rated load.
  3. Ensure that wiring is correct before test in order to avoid light and power supply damage.
  4. If driver Cannot work normally, don’t maintain privately.

Symbols