KICHLER 38259 Kira Flush Mount Ceiling Fixture Instruction Manual

June 9, 2024
KICHLER

KICHLER - logo

38259 Kira Flush Mount Ceiling Fixture
Instruction ManualKICHLER 38259 Kira Flush Mount Ceiling
Fixture

ITEM # 1073457
MODEL # 38259
KIRA FLUSH MOUNT CEILING FIXTURE

38259 Kira Flush Mount Ceiling Fixture

ATTACH YOUR RECEIPT HERE
Serial Number………….
Purchase Date………….

KICHLER 38259 Kira Flush Mount Ceiling Fixture - fig

PART DESCRIPTION QTY.
A Mounting Bracket 1
B Canopy 1
C Shade 1
D Socket 1

HARDWARE CONTENTS

KICHLER 38259 Kira Flush Mount Ceiling Fixture -
HARDWARE

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING

  • CAUTION – RISK OF SHOCK –
    Disconnect Power at the main circuit breaker panel or main fuse box before starting and during the installation.
    WARNING:
    This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.

  • Do not use bulbs with wattage greater than specified on this fixture.

  • California Proposition 65
    WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer, birth defects, or other reproductive harm.
    For more information, go to http://www.P65Warnings.ca.gov

CAUTION

  • If you have any doubts about how to install this lighting fixture, or if the fixture fails to operate completely, please contact a licensed electrical contractor.
  • All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken.  Failure to obey this instruction could invalidate ETL listing and/or C.S.A. certification of this fixture.

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.
Estimated assembly time: 30 minutes to 1 hour
Tools Required for Assembly (not included): Phillips screwdriver, flathead screwdriver, wire strippers, electrical tape, ladder, safety glasses.

ASSEMBLY INSTRUCTIONS

  1. Orient the mounting bracket (A) so that the raised center portion is facing up. Insert long machine screws (DD) through mounting bracket (A) so the  long machine screws (DD) protrude downward. Connect the mounting bracket (A) to the outlet box (not included) with short machine screws (BB).KICHLER 38259 Kira Flush Mount Ceiling Fixture - fig2 Hardware UsedKICHLER 38259 Kira Flush Mount Ceiling Fixture - Used
  2. Wire connection guide:
    Ground wire:
    For installation in the United States: Wrap ground wire from outlet box around ground screw on mounting bracket (A) no less than 2 in. from wire  end. Tighten ground screw. If fixture is supplied with a ground wire, connect to outlet ground wire with a wire connector (AA).
    For installation in Canada: If fixture is supplied with ground wire, wrap ground wire around ground screw on mounting bracket (A). Tighten ground screw. Connect fixture ground wire to outlet ground wire with a wire connector (AA).KICHLER 38259 Kira Flush Mount Ceiling Fixture -
fig3
    Supply wires:
    • Connect the Neutral (White) supply wire from the outlet box to the Neutral fixture wire (White or Parallel Cord “D” shaped and ribbed).
    •  Connect the Hot (Black) supply wire from the outlet box to the Hot fixture wire (Black or Parallel Cord round and smooth).
    NOTE:
    Fixture wires will either be:
    • Black and White.
    • Parallel Cord SPT-1 lamp wire with one round smooth wire and one “D” shaped ribbed wire.

Hardware UsedKICHLER 38259 Kira Flush Mount Ceiling Fixture -
fig1 3a. Pass canopy (B) over the long machine screws (DD) protruding from mounting bracket (A) then secure in place with lock washers (EE) and threaded knobs (CC).
NOTE: The bottom edge of an outlet box should be flush with the bottom surface of a ceiling. However, many boxes are recessed into the ceiling.  The long machine screws (DD) are designed to have extra length to accommodate to various box depths.KICHLER 38259 Kira Flush Mount Ceiling Fixture -
fig53b. 1) The long machine screws (DD) may, at first, protrude too far past the surface of the canopy (B).
2) Screw the threaded knobs (CC) onto the long machine screws (DD). The screws will back thread into the mounting bracket (A) until the canopy  (B) is tight against the ceiling.
Hardware UsedKICHLER 38259 Kira Flush Mount Ceiling Fixture -
fig4

  1. Insert 60-watt max. medium base bulb or LED equivalent (not included) into socket (D).KICHLER 38259 Kira Flush Mount Ceiling Fixture - fig6

CARE AND MAINTENANCE

  • Always be certain that electric current is turned o before cleaning this item.
  • Use a soft, moist cloth with mild non-abrasive soap to clean fixture. Never use glass cleaner on fixture, as it will damage the metal finish.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Fixture does not light. 1. Fixture may be wired incorrectly.
2. Worn or broken bulb. 1. Check wiring.

2. Replace bulb.

Distributed by:
Kichler Lighting LLC
30455 Solon Rd
Solon, OH 44139
Printed in ChinaKICHLER - logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KICHLER User Manuals

Related Manuals