BUSCH JAEGER 2CKA000073B5189 Comfort Sensor 180 Flex User Manual
- June 9, 2024
- BUSCH-JAEGER
Table of Contents
- BUSCH JAEGER 2CKA000073B5189 Comfort Sensor 180 Flex
- INSTALLATION INSTRUCTION
- Comfort sensor 180 flex, multi-lens, wireless
- Intended use
- Declaration of conformity
- Technical data
- Modular system
- Connection
- Mounting
- Detection range
- Setting and operation
- Additional information
- Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BUSCH JAEGER 2CKA000073B5189 Comfort Sensor 180 Flex
INSTALLATION INSTRUCTION
Comfort sensor 180 flex, multi-lens, wireless
DANGER
Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. Work improperly carried out on current-carrying parts can cause fires.
- Disconnect the mains voltage prior to mounting and dismantling!
- Permit work on the 110 – 240 V mains network to be carried out only by specialist staff.
■ Please read the mounting instructions carefully and keep them for future
use.
■ Additional user information and information about planning is available by
scanning the QR code in this manual.
Intended use
The movement detector serves for switching lighting systems in dependence of
brightness and/or movement. It is designed only for interior areas of
buildings. The device is pre-programmed. The function depends on the flex
insert the device has been attached to.
Mounting, among others, is practical on the following flex inserts:
- Relay inserts
- e-contact inserts
- LED dimmer inserts
- Extension unit inserts
The device is not suitable for use as an intrusion or attack alarm since it lacks the required security against sabotage in accordance with the German VdS (Authority on Safety and Security) regulations.
ATTENTION
The device contains highly sensitive sensors and lens systems.
- Do not cover or mask lens segments since this will interfere with the function of the device.
- Do not clean the device and the lens system with abrasive or aggressive cleaning agents.
Declaration of conformity
Busch-Jaeger | ABB herewith declares, that radio system type 62764-xxx-WL conforms to directive 2014/53/EU. The complete text of the EU Declaration of Conformity is available in this manual under the QR code.
Technical data
Opening angle: | 180° |
---|---|
Brightness limit value: | 5 – 500 lux, daytime operation |
Mounting height: | 0.8 m – 2,2 m |
Degree of protection | IP20 |
Temperature range | -5 °C to +45 °C |
Storage temperature | -25 °C to +70 °C |
Transmission protocol | ■ free@home wireless (IEEE 802.15.4) |
■ Bluetooth low energy
Transmission frequency| 2.400 to 2.483 GHz
Maximum transmission|
power|
■ WL (wireless)| < 15 dBm
■ Bluetooth LE (BLE)| < 10 dBm
Modular system
Notice
The movement detector sensors [5 – 6] can be freely combined physically with the flex inserts [1 – 4]. Although not all combinations may be practical with regard to the desired functions.
Function
The function depends on the flex insert used. Depending on the flex insert used, the movement detector [6] operates in one of the following modes:
- Relay insert, 1gang or e-contact insert:
- At movement it switches in dependence of the ambient brightness.
- Relay insert, 2gang:
- At movement, channel 1 switches in dependence of the ambient brightness.
- LED dimmer insert:
- At movement the light dims to the set value.
- Extension unit insert:
- – For the extension of the detection range.
Connection
See the documentation of the respectively used flex insert.
Mounting
Attach the movement detector together with the cover frame on the flex insert [1] / [2]. Flex insert and cover frames are not included in the scope of delivery and must be purchased separately.
Notice
The devices communicate via radio control. The range depends on the structural conditions.
- Walls or ceilings, especially steel reinforcements or metal claddings, reduce the transmission range.
- The distance of components to other transmitters that also emit high-frequency signals (e.g. computers, audio and video systems) should be at least 1 m.
Detection range
The detection range is, among others, dependent on the ambient temperature. The specified values refer to an ambient temperature of 21°C. The detection range is reduced at higher ambient temperatures.
[3+5] Mounting heights / Detection levels [4+6] Detection range Detection range
Mounting height (H)| Lengthways toward the detector| Crosswise
toward the detector
1.1 m| 5 m| 7 m lateral
8 m frontal
2.2 m| 4 m| 8 m
Setting and operation
Setting
The sensor is ready for operation directly after it is attached to the flex
insert. The function depends on the flex insert used. A subsequent further
parameter setting is carried out via the application depending on the
operating mode.
Three different operating modes are available:
- Push-button switch mode
- Local manual operation on the device is always possible via touch rocker [8] / [9].
- Bluetooth® via mobile device or tablet.
- In this operating mode access is established to individual devices or to the entire mesh network via the “Busch-/ABB-free@home® App Next” app.
- System Access Point
- As soon as a System Access Point (from Firmware version 3.0 of the System Access Point) is available in the system, the devices are made operational via the user interface of the System Access Point.
A non-programmed device is made operational via the Busch-/ABB-free@home® App Next app with Bluetooth® or via the System Access Point.
- A login of a non-programmed device into the system is possible at all times via Bluetooth®.
- A login via the commissioning interface of the System Access Point is possible 30 minutes after being energized.
- During this time the device is in programming mode.
- Bluetooth® is deactivated after the device has been programmed via the System Access Point.
A device that has already been logged in must be reset to enable it to be set again into programming mode.
- Keep the bottom button pressed for 20 seconds.
- No LED function for 10 seconds
- The LED flashes slowly for 5 seconds
- The LED flashes fast for 5 seconds
- The LED goes out
- Then press the bottom button again briefly twice.
Additional information
- The device must be parameterized for the use of additional
- Detailed information on commissioning and parameterization is available in the product manual.
- The firmware update takes place via the Busch-/ABB- free@home® App Next app or the System Access Point.
Service
Busch-Jaeger Elektro GmbH – A member of the ABB Group,
Freisenbergstraße 2,
D-58513 Lüdenscheid,
Germany,
Tel.: +49 2351 956-1600;
www.BUSCH-JAEGER.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>