BUSCH-JAEGER 1099 UHK Room Thermostat Cover Plate Instruction Manual

June 3, 2024
BUSCH-JAEGER

BUSCH-JAEGER 1099 UHK Room Thermostat Cover Plate Instruction Manual

1099 UHK Room Thermostat Cover Plate

Safety

| Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
---|---

Intended use

The device is to be used exclusively with the components that are supplied and licensed as described in chapter “Setup and function”.

Environment

| Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
– The device contains valuable raw materials which can be recycled. Therefore , dispose of the device at the appropriate collecting depot.
---|---

All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies.
The products meet the legal requirements , in particular the laws governing electronic and electrical devices and the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)

Setup and function

The temperature controller is used to control the temperature in closed rooms. Application only for de-energized closed actuating drives.

Features of function and equipment
1099 UHKEA 1099 UHK
With manual switch for switchover between cooling/OFF/heating With external

input for switchover between heating and cooling.

Operation

1099 UHK Room Thermostat Cover Plate Operation

No. Function
A LED red Operating mode “Heating” LED blue Operating mode “Cooling”
B Sliding switch at 1099 UH KEA for selecting function B
C Control knob for selecting the desired room temperature

Offset function

1099 UHK Room Thermostat Cover Plate Offset function

Reaching the selected room temperature strongly depends on the ambient conditions such as heating/cooling system capacity (5 K/h min.), room size, ambient temperature, insulation etc.
That is why the values in the scale are merely guide values. To obtain a setting that is as accurate as possible, the adjusting knob (1) can be offset in 4 stages by a total of +/-6°C.
To do so , pull off the control knob and cut off the position lug (2) on its underside using a suitable tool.
Then shift the control knob by the desired correction temperature in relation to the vertical and put it back on.

Technical data

General

Nominal voltage 230 V ~ ±10%, 50 / 60 Hz
Switching capacity (inductive) heating 10 (4) A, 230 V ~
Switching capacity (inductive) cooling 5 (2) A, 230 V ~
Connection 1.5 mm² … 2.5 mm²
Temperature adjustment range ~ 5 to 30°C (1 = 5°C
20°C 5 = 25°C
Switching temperature difference * Approx. +/- 0.5 K
Protection type IP 20, (EN 60529)
Power loss (Relay off) 0.5 W

Switch contact (independent normally open

contact)

| 2
Mode of operation (DIN EN 60730-1)| 1 B
Degree of contamination (DIN EN 60730-1)| 2
Rated surge voltage (DIN EN 60730-1)| 4000 V

Typical control operation can not always be attained for cooling areas close to the floor. When the device heats up due to high current loads , the set value should be checked especially in cooling operating mode and, if necessary, the set-point temperature should be raised .

Installation and electrical connection

| Warning
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
– Low-voltage and 230 V lines must not be installed together in a flush- mounted socket!
---|---

Requirements for the electrician

| Warning
Electric voltage!

  • Install the device only if you have the necessary electrical engineering knowledge and experience.

  • Incorrect installation endangers your life and that of the user of the electrical system.

  • Incorrect installation can cause serious damage to property, e.g. due to fire.
    The minimum necessary expert knowledge and requirements for the installation are as follows:
    Apply the “five safety rules” (DIN VDE 0105, EN 50110):
    1. Disconnect from power;
    2. Secure against being re-connected ;
    3. Ensure there is no voltage;
    4. Connect to earth and short-circuit;
    5. Cover or barricade adjacent live parts.

  • Use suitable personal protective clothing.

  • Use only suitable tools and measuring devices.

  • Check the supply network type (TN system, IT system , TT system) to secure the following power supply conditions (classic connection to ground, protective earthing , necessary additional measures, etc.).

---|---

Mounting

| Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
---|---

The flush-mounted insert must only be installed in flush-mounted wall boxes according to DIN 49073-1, Part 1, or suitable surface-mounted housings.

Note
Use only in dry rooms!

1099 UHK Room Thermostat Cover Plate Installation and electrical
connection

No. Function
A Height: 150 cm/minimum distance: 30 cm
B Avoid mounting on thermal bridges
C Avoid draught and direct sunlight
D Avoid the heat radiation of external devices

1099 UHK Room Thermostat Cover Plate Installation and electrical
connection
1099 UHK Room Thermostat Cover Plate Installation and electrical
connection

To put on the adjustment wheel , turn the two arrows towards each other (1 ). The position lug (3) on the adjustment wheel (2) can now be put on in its normal vertical position.

Electrical connection

1099 UHK Room Thermostat Cover Plate Installation and electrical
connection
1099 UHK Room Thermostat Cover Plate Installation and electrical
connection

Terminal designation Assignment
Input 1099 UHK for switchover to cooling mode
Output for controlling the heating load
Output for controlling the cooling load

Note
At high humidity (tendency toward thunder storms) during cooling mode, attention should be paid to dew formation on the cooled surface.
Cooling should be reset early or switched off completely to prevent moisture from damaging the cooled surface .

Commissioning

Note
When the temperature controller is used for the first time , it has to be taken into account that the switching point precision is not reached until about 1-2 hours of operation after installation.
It is recommended to set a temperature that is higher (heating operation) or lower (cooling operation) than actually desired, to reduce the time required for initial adaptation.

A member of the ABB Group

Busch-Jaeger Elektra GmbH
PO box
58505 Ludenscheid

Freisenbergstral1e 2
58513 Ludenscheid
Germany

www.BUSCH-JAEGER.de
info.bje@de.abb.com

Central sales service:
Phone: +49 (0) 2351 956-1600
Fax: +49 (0) 2351 956-1700

Notice
We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice.
The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.

We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB.

Copyright© 2014 Busch-Jaeger Elektra GmbH All rights reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BUSCH-JAEGER User Manuals

Related Manuals