eta Sonetic AquaCare Oral Care Centre User Manual
- June 9, 2024
- ETA
Table of Contents
eta Sonetic AquaCare Oral Care Centre
INSTRUCTIONS FOR USE
Dear customer, thank you for purchasing our product. Please read the operating instructions carefully before putting the appliance into operation and keep these instructions including the warranty, the receipt and, if possible, the box with the internal packing.
GENERAL SAFETY INSTRUCTIONS
-
Consider the instructions for use as a part of the appliance and pass them on to any other user of the appliance.
-
Please check if the voltage specified on the rating place complies with the voltage in your electrical socket (this product is designed to operate within a range of
100- 240 volts). The charging base must be connected to an electric socket in the electrical mains complying with the applicable standards. -
This product is not intended for use by children under 3. Children at the age of 3 to 14 and persons with limited physical, sensory or mental capabilities may only use the toothbrush if they are supervised or have been instructed of the use of
the appliance in a safe manner and understand possible risks. The oral shower may be used by children older than 8 years, and persons with limited physical, sensory or mental capabilities or lack of experience and knowledge, provided they are supervised. Children must not play with the appliance. Children must not perform cleaning and maintenance intended to be performed by users unless they are older than 8 years and are under supervision. Children under 8 years of age must be kept out of reach of the appliance and its charging base. -
If the charging base or its power cord is damaged, it must be replaced by the manufacturer, its service technician or a person with similar qualifications, to prevent the occurrence of hazardous situations.
-
Never use the appliance if the charging base, power cord or plug is damaged, if it operates incorrectly, fell on ground or is damaged, or if the charging base fell into water. In such cases bring the appliance to the specialised repair shop to verify its safety and correct functionality.
-
The connected charging base must not be used at the places where it could fall in bathtub, sink or swimming pool. If it falls into water yet, do not take it out!First disconnect the appliance from the electrical socket, and then take it out from water. In such cases bring the application to the repair shop to verify its safety and correct functions.
-
For additional protection, we recommend installing a protective switch (RCD) in the electrical circuitry of the bathroom, with the nominal actuating current not exceeding 30 mA. Ask an inspecting technician or an electrician for advice.
-
The appliance is only intended for individual use at home for personal oral cavity care! It is not intended for commercial use, for more than one patient in dentist’s consulting rooms or in any other healthcare facilities!
-
The charging base provided with appliance is only designated for this appliance. Do not use it for other purposes. Only use the provided charging base for this appliance, do not use other types of charging base for recharging (for example from other appliance).
-
Do not use the application in exterior or where aerosol products are used (such as sprays), or where oxygen is handled.
-
Do not use the charging base during bathing.
-
A guarantee of 24 months does not apply to a decrease in the accumulator’s effective capacity caused by its use or age. Effective capacity gradually decreases depending on the method of use of the accumulator.
-
Do not plug or unplug the charging base power cord to/from the electrical socket with wet hands!
-
Never immerse the charging base in water or other liquids (not even partially) and do not wash it under running water!
-
Do not insert the appliance or its accessories in any body cavities, except for oral cavity.
-
The appliance is not designed to care for animal teeth.
-
Only use the charging base at horizontal position at places where overturning is not imminent, and in a sufficient distance from heat sources (such as stove, fireplace, or heat radiators).
-
Clean the accessories after each use. Failure to adhere to this instruction might cause worsening your state of health, because without disinfection, spread of mildew and bacteria is supported.
-
Do not leave the appliance unattended!
-
Charge the accumulator at the normal room temperature. Do not expose the accumulator to temperatures higher than 50 °C to prevent causing damage to the accumulator.
-
The accumulator must not be removed when the appliance is normally used. Only remove the accumulator if the appliance is to be discarded (see article V. ECOLOGY).
-
Protect the appliance from dust, chemicals, excessive humidity, toiletries, liquid cosmetics, large fluctuations
in temperature, and do not expose it to direct sunshine. -
WARNING : Do not use the appliance with a program, time switch or any other part that turns the appliance on automatically.
-
Do not attempt to repair the appliance by yourselves.
SPECIAL SAFETY INSTRUCTIONS
-
The appliance should never be used by persons with reduced sensibility in oral cavity, otherwise injury of
or damage to teeth or gums might occur. If you have unpleasant feeling in your mouth or if you feel pain during the cleaning, stop using the appliance and contact your dentist. Contact the dentist also in the case that you have any doubt about use of the appliance in your individual case. -
If your toothpaste contains peroxide, baking soda or other bicarbonate (frequently used in whitening toothpastes), thoroughly clean the brush and its handle after use to prevent damaging the appliance.
-
Do not use the appliance in care for children, incapacitated persons or persons who are unable to express their feelings.
-
If you have undergone tooth or gum operation recently, suffered long-term problems with your teeth or were subject to extensive medical interventions in the last 2 months, or if you suspect problems of dental character (with fillings, crowns, etc.), consult your dentist before using the appliance.
-
If you experience any health troubles (for example considerable bleeding, or if any bleeding persists even after 2 weeks of use of the brush), stop using the appliance and contact your physician for consultation.
-
Do not press the jet tip strongly against your teeth or gums.
-
Do not put the oral shower into operation, if the water container is empty or if the jet is removed.
-
Do not aim the jet at the area under your tongue, in throat, ears, nose or other sensitive body parts, as you can suffer injury.
-
Never aim the water flow at persons, animals, plants or equipment containing electrical parts and their power cords.
-
Due to manufacturing tests, the inside of the suction hose or the container of the appliance may be covered with condensation. This is not considered as a defect upon purchase.
-
The oral shower may only be used with cold water or water up to 40 °C. In no case pour hot water, oral waters, essential oils, water with alcohol, salt, vinegar, decalcification agents, softeners or other chemical agents in the oral shower container. Do not put any items in the container.
-
The appliance complies with the safety standards for electromagnetic radiation. However if you use any of the following devices: cardiostimulator, electrocardiograph or other medical device implanted in your body or used as a support, consult your physician or the implant manufacturer before use.
-
For hygienic reasons do not share the same toothbrush/jet with another person or more persons. Infections could spread or oral cavity inflammation could be initiated.
-
The charging base power cord must not be damaged by sharp or hot items or open flam, and they must not be immersed in water or bent over sharp edges. They must not freely hang over the desktop edge within reach of children.
-
If you need to use an extension cord, it has to be uncorrupted and it has to comply with the valid standards.
-
Regularly check the condition of the charging base power cord.
-
Only use the appliance with the original accessories designated for the respective type. Do not use damaged/deformed adapters.
-
Only use this appliance including its accessories for the designated purpose as described in this instruction manual. The appliance is only designed for cleaning teeth, gums and tongue. Never use the appliance for any other purpose.
-
WARNING : There is a risk of injury in case of incorrect use (not in accordance with the manual) of the appliance.
-
All text in other languages and pictures shown on the packaging, or the product itself, are translated and explained at the end of this language mutation.
-
The producer does not undertake any responsibility for damage caused by improper use of the appliance (e.g. injury etc.) and its guarantee does not cover the appliance in the case of failure to comply with the safety warning above.
DESCRIPTION OF FEATURES
- A – Brush body
- A1 – ON/OFF switch + mode switch (POWER; ON/OFF)
- A2 – active mode indicator
- A3 – battery indicator light
- B – Brush (3 pcs included)
- B1 – brush head
- B2 – coloured ring to distinguish users
- C – Oral irrigator body
- C1 – ON switch
- C2 – mode switch button
- C3 – active mode indicator
- C4 – nozzle ejector button
- C5 – suction hose
- C6 – protective filter
- C7 – water reservoir
- C8 – reservoir plug
- D – Attachments
- D1 – nozzle for teeth and gums (3 pcs included)
- D2 – coloured ring to distinguish users
- D3 – tongue scraper (1 pc included)
- D4 – orthodontic tip nozzle
- E – Charging base
- E1 – charging base projections
- E2 – projections for storage of attachments
- E3 – power cable
- F – Protective travel case
Note : Replacement attachments (B, D1, D3, D4) can be purchased under order numbers ETA 070790100; ETA 070790200 (soft); ETA270790100; ETA 270790300 and ETA 270790200.
INSTRUCTIONS FOR USE
Remove all packaging materials and take out the appliances and any accessories. Parts which come in contact with the oral cavity must be rinsed in warm drinking water before first use.
BRUSH AND ORAL IRRIGATOR CHARGING
These appliances are equipped with a contactless (induction) charging system which works on the principle of energy transfer through an electromagnetic field. No direct connection with the power cable is required which makes charging more convenient and thanks to the enhanced insulation (IPX7) also safer
Connect the charging base power plug to the mains first and place the brush body (A) / oral irrigator body (C) onto the appropriate cylindrical projection (E1) in the charging base (E). The charging procedure is signalled by a flashing (A3/ bottom C3) LED indicator. When the battery is fully charged, the (A3/ bottom C3) LED indicator is lit. For a full charge, the battery needs to be charged for approximately 10/18 hours (brush/oral irrigator respectively). Depending on the cleaning mode used, a fully charged brush battery (A) will provide approximately 2-3.5 hours of operation which corresponds to about 1-2 months when used twice a day for two minutes. The oral irrigator (C), depending on the cleaning mode, can empty approximately 55 – 75 water reservoirs (C7), which will last for about 2-3 weeks if used twice a day for two minutes as well.
Note : Although the brush / oral irrigator should not be charged before they are fully discharged, we recommend charging them at regular intervals in order to ensure maximum battery life (e.g. after 2-3 weeks of use).
Caution
- During operation, the (A3) LED indicator is lit, when the battery of the accumulator is low and it needs to be recharged, the LED indicator starts flashing.
- When charged for the first time, or if the appliances were not in use for more than 3 months, they need to be charged for 24 hours.
- Do not exceed the recommended time of charging (10/18 hours) during regular charging!
- The charging base also serves as a stand where you can place the brush / oral irrigator after use. However, do not connect the base to the mains unless you wish to charge the appliances. Do not leave the charging base connected to the mains permanently!temperature, age, method of charging, etc.
- The operating times are only approximate. The time depends on the condition of the battery, ambient temperature, age, method of charging, etc.
USE
BRUSH (A)
Before use, slide the brush (B) onto the brush body (A) to connect them (See
Fig. 1). A small gap will remain between the brush body (A) and the coloured
ring (B2) which is not a defect. To remove the brush, proceed the other way
round. Do not switch on the appliance without the brush attached!
Moisten the brush and apply a small amount of toothpaste on it. Put the brush
to the teeth at a slight angle towards the gums (see Fig. 4A) and switch on
any mode by pressing the mode on/switch button (A1). Move the brush slowly
along the teeth back and forth, applying a slight pressure, so as not to miss
any tooth or area in the mouth. Clean each tooth for about 2-3 seconds.
The brush operating time is limited to 2 minutes which corresponds to the time
for cleaning recommended by experts. If you wish to continue cleaning, simply
switch on the brush again. Each part of the mouth (quadrant) should be cleaned
for about 30 seconds (see Fig. 4B); A short interruption of the brush
operation will prompt you to move to another quadrant after this time elapses.
Mode on/switch button control A1
When you press the button once, the brush switches on
in mode C. If you press the button again within 3 seconds, the brush will
switch to mode S. If you press the button repeatedly within 3 seconds, the
brush will switch to mode M. When you press the button again, the brush will
switch off. The brush will also switch off if you press the button (A1) in
mode C/S after 3 seconds after its activation.
Cleaning modes:
- C mode – standard intensive mode for regular cleaning of healthy teeth,
- S mode – gentle mode for sensitive teeth or mouth parts; recommended in case of increased sensitivity of teeth, exposed necks, periodontitis, implants and other dentures,
- M mode – pulse mode for gentle gum massaging.
Activation of the mode selected is indicated by the indicator (A2) coming on.
Notes
- If this is your first sonic toothbrush and you have not had any experience with this cleaning technology, it might take you a while to get used to the specific tingling. However, most users say that they got used to it quickly after a few uses and cleaning became perfectly natural for them.
- Do not apply excessive pressure on your teeth.
- You can also use this brush when you have fixed braces, facets, crowns, etc. However, please bear in mind that if the brush is used with braces, the brush bristles are subject to more wear.
- We recommend that you replace the brush (B) with a new one after 3 months of use. However, if the brush is showing signs of significant wear or damage.
ORAL IRRIGATOR (C)
- The water system must be flushed out before first use.
- Fill the water reservoir (C7) with clean drinking water according to the following instructions, re-assemble the appliance and switch it on. Allow all the water to run through the oral irrigator to the washbasin. Repeat this procedure at least twice.
- Assembly/disassembly of the individual components Water reservoir (C7) – to remove the water reservoir from the oral irrigator body (C), pull it downwards (see Fig. 2).
- Water can be refilled in one of two possible ways (see Fig. 2A/2B) and in order to refill water in accordance with Fig. 2B, you need to remove the reservoir plug (C8) first and attach it properly back when water has been refilled. Re-attach the reservoir to the oral irrigator body (C) in the opposite way.
- Attachments (D1, D3, D4) – attach the selected nozzle into the opening at the top of the oral irrigator body (C) until it locks in place (you will hear a click). “Pull” the attachment slightly so as to check that it is properly fitted. To remove the attachment, press the ejector button (C4) first and take out the attachment pulling it gently.
Button control
Using the mode switch button (C2), select a cleaning mode first:
- N mode – standard intensive mode for regular cleaning of healthy teeth and gums,
- S mode – gentle mode for sensitive teeth and gums,
- P mode – pulse mode for gentle gum massaging.
The selected mode can be changed even when cleaning is in process. Activation
of the mode selected is indicated by the indicator (C3) coming on.
Activate the appliance by pressing the ON switch (C1). When you press the ON
switch again, the appliance will switch off.
Method of use (Fig. 4C)
As plague which clings to the teeth surface cannot be removed simply with a stream of water, it is necessary to clean your teeth thoroughly with a toothbrush before using the oral irrigator. You will need the sonic toothbrush for this which is included in the box.
As soon as you have cleaned your teeth replace the brush with the oral
irrigator. Attach the selected nozzle (D1) to the oral irrigator and put the
nozzle tip between two teeth at the gum line level at a 90 degree angle. To
prevent the water from splashing, press the lips slightly together around the
nozzle, but keep the mouth slightly open so that water can flow out smoothly.
Lean over the washbasin while cleaning your mouth. Slowly guide the nozzle
until you feel it settle between the next two teeth, smoothly follow the gum
line and the shape of your teeth. Continue doing so until you clean all inter-
dental spaces, including the molars, in all areas of the mouth. Do not apply
any pressure on the nozzle, let it do all the work on its own. Depending on
the selected mode of cleaning, the full water reservoir (C7) will last for
about 45 – 60 seconds. For optimal mouth irrigation, we recommend refilling
the reservoir 2-3 times.
Tongue scraper (D3)
Use the tongue scraper to clean your tongue. To clean the tongue, move the attachment gently across the entire area of the tongue back and forth. Start cleaning with the S mode; switch to the N mode if required.
Orthodontic nozzle (D4)
The nozzle is designed for cleaning hard-to-reach areas around fixed braces. Guide the nozzle slowly along fixed braces, smoothly contouring their shape. Stop shortly at each tooth and use the brush at the end of the nozzle to clean the area around the braces wires and locks. Continue doing so until you clean all teeth, including the molars, in all areas of the mouth. Do not apply any pressure on the nozzle, let it do all the work on its own.
When cleaning is finished
- Open the water reservoir (C7) and empty it, pouring any remaining water in the washbasin.
- Switch the oral irrigator on for a few seconds so as to empty the inside as well.
- Wipe all the components with a dry cloth.
Caution
- If you are not going to use the oral irrigator for some time, let it dry properly when disassembled after the last use!
- During the first few days of using the oral irrigator, your gums might bleed slightly but this usually stops on its own after a few days.
- To ensure the best results when cleaning, we recommend replace every 3 months (the orthodontic tip nozzle) and 6 replace every 6 months (the nozzle / tongue scraper) However, if the attachments are showing signs of significant wear or damage, replace them sooner.
CLEANING AND MAINTENANCE
For maximum hygiene, clean the brush (B) and oral irrigator (C) after each
use! Rinse the attachments (B/D) and the brush (B) under running water.
Wipe the brush body (A) with a damp cloth. Use the damp cloth to wipe the oral
irrigator body (C), charging base (E) and its cable as well.
Other important notes:
- Before performing maintenance of the charging base (E), unplug it from the mains first!
- Never immerse the appliance bodies (A/C) or the charging base (E) in water!
- Do not clean the appliance in a dishwasher and do not use any aggressive cleaning agents for cleaning!
- Never use water at a temperature exceeding 50 °C to clean the oral irrigator (C).
- Allow all the appliance components – except for the attachments (B/D) – to dry properly before their re-use.
- Make sure that the suction hose (C5) and protection filter (C6) do not get damaged during maintenance and (if removed) that they are re-attached before use.
Store the appliance and all the accessories in a dry, dust-free and safe
place, out of reach of children and incapacitated persons.
If the suction hose (C5) or the protective filter (C6) is damaged/lost,
purchase their replacement under order number ETA 270700040.
ENVIRONMENTAL PROTECTION
If the dimensions allow, there are labels of materials used for production of
packing, components and accessories as well as their recycling on all parts.
The symbols specified on the product or in the accompanying documentation mean
that the used electrical or electronic products must not
be disposed of together with municipal waste. For proper disposal of the
product, hand it over at special collection places where it will be taken over
free of charge. Suitable disposal of the product can help to maintain valuable
natural resources and to prevent possible negative impacts on the environment
and human health, which could be the possible consequences of improper waste
disposal. Fines can be imposed for improper disposal of this type of waste in
agreement with the national regulations. This appliance is equipped with Li-
ion batteries with a long service life. For environmental protection it is
necessary to remove
the battery from the appliance after its service life and the battery and the
appliance must be disposed of safely using special collection networks. Ask
for more details at the local authority or at the local waste collection site.
Removing the battery
Remove the battery from the appliance only when completely discharged (i.e.
leave the appliance running until it stops).
Brush (A)
The procedure for removing the battery is shown in Fig. 5:
- Using a screw-driver, remove the screw cover and loosen the screw.
- Hold the brush body (A) upside down, press the charging part (see arrows in the figure) and remove the 2 hooks which hold the inner components of the brush body (A).
- Remove the battery from the compartment using a screw-driver.
Oral irrigator (C)
- Remove the two feet situated at the bottom of the oral irrigator.
- Using a screw-driver, unscrew the bottom cover thought the bottom slot anti-clockwise.
- Unscrew the two screws situated at the top part of the oral irrigator – after you have removed the reservoir (C7).
- Remove the batteries from the compartment.
TECHNICAL DATA
- Voltage (V) shown on the type label of the appliance
- Weight (kg) approximately 0,6
- Appliance/Adapter Protection Class III./II.
- Size, (mm): 250 x 30 x 30; (A) 270 x 75 x 57 (C)
- Operating pressure (mode N,S,P) 100;60;30-140 PSI
The manufacturer reserves the right to change the technical specifications and
accessories for the respective models. Expert service must do the large
maintenance or to intervene into inside parts of the appliance! Non-observance
of the instructions of the manufacturer cancels the right for guarantee
repair!
Guarantee of 24 months does not apply to decrease in the accumulator’s
effective capacity caused by its use or age. Effective capacity gradually
decreases depending on the method of use of the accumulator. This appliance
contains batteries that are not replaceable.
HOUSEHOLD USE ONLY; DO NOT IMMERSE IN WATER OR OTHER LIQUIDS;
TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.
Hersteller/ Inverkehrbringer: ETA a.s., Křižíkova 148/34, Karlín, 18600
Praha 8 CZECH REPUBLIK
Service: Omega electric GmbH, Servicezentrale, Industriering 2, D- 04626
Schmölln.
Tel.: 034491/58860, Fax: 034491/5886189
Email : info@omega-hausgeraete.de
© DATE 14/6/2017
References
- Strona Główna - Digison
- AEG Hausgeräte | Setzen Sie auf Qualität | AEG
- ETA - tady je doma
- ETA - tu je doma
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>