SERVER FSAF Advantage Topping Warmer
Advantage™ Topping Warmer
MODEL: FSAF 85070 COMPLETE
Thank You for your purchase. This high-volume, pouched topping warmer
virtually eliminates product degradation and waste, so you can reduce food
costs while delivering a superior product.
SIMPLIFY TOPPING MANAGEMENT—GO POUCHED
PARTS FOR 85070
SAFETY
WARNING
ELECTRICAL SHOCK COULD OCCUR This unit must be earthed or grounded.
This requires all three prongs (terminals) on cord plug to be plugged into
power source. Intended to be used with non-potentially hazardous foods.
According to food and safety regulations, most foods must be stored and/or
served at certain temperatures or they could become hazardous. Check with
local food and safety regulators for specific guidelines. Be aware of the
product you are serving and the temperature the product is required to
maintain. Server Products, Inc. can not be responsible for the serving of
potentially hazardous product
PRE-HEATING PRODUCT POUCHES
- Install pump with pouch. (See UNIT SETUP, pg. 4.)
- Adjust thermostat to food manufacturer’s recommended serving temperature.
UNIT SETUP
WASH ALL PARTS PROPERLY BEFORE EVERY USE. See page 6.
SEE SEPARATE PUMP MANUAL FOR PUMP SETUP.
- ATTACH PUMP TO POUCH
- Place pouch on countertop with pouch fitment circle facing upward.
- Position pump connector directly over center of pouch fitment.
- Press pump connector down to pierce through film in pouch fitment.
- INSTALL PUMP WITH POUCH INTO BASE
- ADD LID
- PLUG CORD into power source.
- PRESS SWITCH to the “ON” position.
- SET THERMOSTAT KNOB
- to food manufacturer’s recommended serving temperature.
- Thermostat range is 100º F/38º C—200º F/ 93º C.
UNIT TAKE-DOWN
- PRESS SWITCH to the “OFF” position.
- UNPLUG CORD
CAUTION- HOT
Allow unit to cool before continuing or use proper care with hot surfaces.
-
REMOVE LID
-
REMOVE PUMP
-
DETACH POUCH from bottom of pump.
-
FLUSH AND RINSE PUMP
Thoroughly rinse all inside and outside surfaces of pump with hot water. -
DISASSEMBLE AND CLEAN PUMP.
SEE SEPARATE PUMP MANUAL FOR PUMP CLEANING.
CLEANING
SEE SEPARATE PUMP MANUAL FOR PUMP INSTRUCTIONS.
WARNING-
ELECTRICAL SHOCK COULD OCCUR
- Electrical components of unit could be damaged from water exposure or any liquid.
- Never immerse unit into water or any liquid.
- Never use any water jet or pressure sprayer on unit.
- Ensure unit is “OFF” and unplugged.
CAUTION- HOT
Allow unit to cool before cleaning.
CLEAN EXTERNAL SURFACES
- Wipe daily with a clean damp cloth.
- Dry with a clean soft cloth.
- Glass and surface cleaners approved for use in food contact areas may be used.
LID CLEANING
Lid may be wiped clean with dishwashing soap & hot water.
CARE OF STAINLESS STEEL
This warmer and accessories are constructed of stainless steel— one of the best materials for food serving and storage. If you notice corrosion beginning on any stainless steel surface, you may need to change the cleansing agent, sanitizing agent, or the cleaning procedures you are using.
- A mildly abrasive nylon or brass brush may be used to remove any stubborn food or mineral deposits on interior surfaces of unit.
- Fully rinsing and drying all parts can help prevent corrosion. Elements and minerals in tap water can accumulate on stainless steel parts and create corrosion.
- Do not use abrasive, caustic or ammonia based cleansers.
- Do not use products containing acids, alkalines, chlorine, or salt. These agents can corrode stainless steel.
- Do not use metal scrapers or cleaning pads that could scratch surfaces.
WIRING
85060 | 120V | USA
- Cord Assembly
- Bushing/Strain Relief
- Wire Nut
- Heating Element
- Green Wire Assembly
- Thermostat
- Black Wire Assembly
- Black Wire Assembly
- Snap-In Rocker Switch
TROUBLESHOOTING
UNIT DOES NOT HEAT?
- Ensure cord is securely plugged in.
- Ensure unit is on.
- Ensure thermostat knob is set correctly.
- Ensure power is available from source.
- Do not allow any of the electrical components to get wet. Moisture may cause the unit to trip breaker or GCFI. If moisture is suspected, discontinue use. Allow unit to fully air dry.
POUCH DOES NOT EVACUATE ALL PRODUCT?
- Ensure that the pouch is properly connected with pump.
SERVER PRODUCTS LIMITED WARRANTY
This Server product is backed by a two-year limited warranty against defects in materials and workmanship. See Server-Products.com for details.
GENERAL SERVICE, REPAIR OR RETURNS
Before sending any item to Server Products for service, repair, or return,
contact Server Products customer service to request a Return Authorization
Number. Merchandise must be sent to Server Products with this number. Service
is extremely prompt. Typically, units are repaired and ship out within 48
hours of receipt.
Merchandise being returned for credit must be in new and unused condition and
not more than 90 days old and will be subject to a 20% restocking charge.
Electrical parts (thermostats, heating elements, etc.) are not returnable.
Servicing Cord: Specific tools are required for safe and proper power supply
cord removal and installation. If cord must be replaced, only a representative
of the OEM (original equipment manufacturer) or a qualified technician may
replace cord. Cord must meet code designation H05 RN-F requirements.
NEED HELP?
Server Products Inc.
3601 Pleasant Hill Road Richfield, WI 53076 USA
Chat with us!
spsales@server-products.com
262.628.5600 | 800.558.8722
Please be prepared with your Model, P/N and Series located on the lid or base of the unit.