ACURITE 01071 Weather Station with Lightning Instruction Manual
- June 9, 2024
- Acurite
Table of Contents
- ACURITE 01071 Weather Station with Lightning
- Unpacking Instructions
- Features & Benefits
- SETUP
- Display Setup
- OPERATION
- Troubleshooting
- Care and Maintenance
- Specifications
- FCC Information
- Customer Support
- Limited 1-Year Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ACURITE 01071 Weather Station with Lightning
Weather Station with Lightning
model 01071
Questions? We’re here to help!
Visit us online at www.acurite.com/support
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection www.acurite.com
/product-registration
Features & Benefits
Outdoor Sensor
-
Integrated Hanger For easy placement.
-
Wireless Signal Indicator Flashes when data is being sent to the display.
-
Interference Indicator Flashes when interference is detected (see page 10).
-
A-B-C Switch ID code that must match display’s
A- B-C switch to ensure units synchronize. -
Battery Compartment
-
Lightning Strike Indicator Indicates a lightning strike has occurred within 25 miles (40 km).
-
Battery Compartment Cover
NOTE: Under no circumstances shall the Lightning Detection Sensor, Chaney Instrument Co. or the Primex Family of Companies be held responsible for any damages whatsoever that may result from the use of or inability to use this product, including without limitation any indirect, incidental, special, exemplary or consequential damages, which are expressly disclaimed. This disclaimer of liability applies to any damages or injury caused by any failure of performance, error, omission, inaccuracy, interruption, deletion, defect, delay in operation or transmission software virus, communication failure, theft or destruction or unauthorized access to, alteration of, or use of the product, whether for breach of contract, tortuous behavior (including, without limitation, strict liability), negligence, or under any other cause of action, to the fullest extent permissible by law. This does not affect any statutory rights which may not be disclaimed. The contents of this product, including all lightning and weather data are provided “as is” and without warranty or condition of any kind, express or implied, including, without limitation, any warranty of merchantability or fitness for a particular purpose. Chaney Instrument Co. & the Primex Family of Companies do not warrant that this product or the data that it provides will be free of errors, interruptions, viruses or other harmful components. Chaney Instrument Co. & the Primex Family of Companies do not warrant the accuracy or reliability of any lightning strike alerts, weather data or other information provided by the product. Chaney Instrument Co. & the Primex Family of Companies reserve the right to alter the product or withdraw it from the market at its sole discretion.
Front of Display
-
Heat Index Alert Indicates when the heat index is above 90°F (32°C).
-
Current Outdoor Temperature
-
Current Outdoor Humidity
-
Current Barometric Pressure Arrow icon indicates the direction pressure is trending.
-
Weather Forecast 12 Hours in Advance Self-Calibrating technology pulls data from the outdoor sensor to generate a hyperlocal, personalized forecast.
-
Learning Mode Icon Disappears after weather forecast self-calibration is complete.
-
Time
-
Display Low Battery Indicator
-
Current Indoor Temperature
-
Current Indoor Humidity
-
Records Button For viewing high and low records.
-
Date
-
set Button
For setup preferences. -
Icon
Indicates the display is in auto-dimming brightness mode -
UP and DOWN Buttons For setup preferences.
-
MUTE Button
Silences the audible lightning alert. -
Interference Indicator
Indicates when interference is detected. -
Strike Counter
Displays most recent total of lightning strikes that has been detected (today, this week, this month). -
Estimated Distance to Storm Front Updates with latest lightning strike detected today.
-
Sensor Low Battery Indicator
-
Outdoor Sensor Signal Strength
-
Freeze Alert Indicator
Indicates temperature is below freezing (32°F; 0°C).
Back of Display
-
Backlight Button
For momentary backlight and dimmer settings. -
Integrated Hangers
For easy wall mounting. -
Backup Battery Compartment
-
A-B-C Switch
ID code that must match sensor’s A-B-C switch to ensure units synchronize. -
Plug-in for Power Adapter
-
Power Adapter
-
Battery Compartment Cover
-
RESET Button
For full reset to factory defaults.
SETUP
Sensor Setup
-
Set the A-B-C Switch
The A-B-C switch is located inside the battery compartment. Slide to set the channel to A, B or C. However, you must select the same letter choices for both the sensor and the display in order for the units to synchronize. -
Install or Replace Batteries
AcuRite recommends high quality alkaline or lithium batteries in the wireless sensor for the best product performance. Heavy duty or rechargeable batteries are not recommended. The sensor requires lithium batteries in low temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the sensor for temperatures below -4˚F / -20˚C. -
Slide off the battery compartment cover.
-
Insert 4 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
-
Replace the battery cover.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior
to battery installation. Remove batteries from equipment which is not to be
used for an extended period of time. Follow the polarity (+/-) diagram in the
battery compartment. Promptly remove dead batteries from the device. Dispose
of used batteries properly. Only batteries of the same or equivalent type as
recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose
of batteries in fire, as batteries may explode or leak. DO NOT mix old and new
batteries or types of batteries (alkaline/standard). DO NOT use rechargeable
batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit
the supply terminals.
Display Setup
-
Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the display and the sensor in order for the units to synchronize.
-
Install or Replace Backup Batteries (optional)
-
Remove the battery compartment cover.
-
Insert 3 x AAA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/–) diagram in the battery compartment.
-
Replace the battery cover.
-
Plug in Power Adap ter
For the best performance, plug in the power adapter as the main power source for this product.
Set the Time, Date & Units
Press and release the “set” button, located on the front of the display, to
enter SET MODE. Once in set mode, the preference you are currently setting
will blink on the display.
To adjust the currently selected (flashing) item, press and release the “ ” or
“ ” buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “set” button again to adjust
the next preference. The preference set order is as follows:
- CLOCK HOUR
- CLOCK MINUTE
- CALENDAR MONTH
- CALENDAR DATE
- CALENDAR YEAR
- UNITS SCALE (U.S. standard or metric)
You will automatically exit SET MODE if no buttons are pressed for 10 seconds. Enter SET MODE at any time by pressing the “set” button.
Display Backlight Settings
This weather station’s color display features three different lighting
settings: High (100%) brightness, Medium (60%) brightness and Low (15%)
brightness.
When display is powered with the power adapter, backlight remains on at 100%
brightness. Press the “” button once to dim to 60% brightness; press again to
dim to 15%, press a third time to enter AUTO-DIM mode.
NOTE: Pressing and holding the “” button for 5 seconds will disable the
backlight. Once any button is pressed, the backlight will return to your
selected setting.
AUTO-DIM MODE: Automatically adjusts display brightness based on time of day.
6:00 a.m. – 9:00 p.m. = 100% brightness
9:01 p.m. – 5:59 a.m.= 15% brightness
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display and the outdoor sensor are critical to the
accuracy and performance of this product.
Display Placement
Place the display in a dry area free of dirt and dust. Display stands upright
for tabletop use or is wall-mountable.
Outdoor Sensor Placement
Sensor must be placed outside to observe outdoor conditions. Sensor is water-
resistant and is designed for general outdoor use, however, to extend its life
place the sensor in an area protected from direct weather elements.
Hang the sensor using the integrated hang holes or hanger, or by using string
(not included) to hang it from a suitable location, like a well covered tree
branch. The best location is 4 to 8 feet (1 to 2 meters) above the ground with
permanent shade and plenty of fresh air to circulate around the sensor.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
- Display and outdoor sensor must be within 330 ft (100 m) of each other.
- To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
- To prevent wireless interference, place both units at least 3 ft (90 cm) away from electronic devices (TV, computer, microwave, radio, etc.).
Setup is Complete
The sensor will now synchronize with the display. It may take a few minutes
for synchronization to complete. Please refer to the troubleshooting section
of this manual if anything appears to be functioning improperly.
Lightning Detection
The sensor detects cloud-to-cloud, cloud-to-ground and intra-cloud lightning.
When lightning is detected, the sensor will beep and the strike indicator will
flash for each of the first 10 strikes. After 10 strikes, the sensor will
enter silent mode but will continue to flash. The sensor will stay in silent
mode for 2 hours after the last lightning detection. The display will also
have an audible and visual alert when lightning is detected. To temporarily
silence the lightning alert, press and release the “MUTE” button. This will
silence all alerts for the current storm detected. To permanently silence all
current and future lightning alerts, press and hold the “MUTE” button for 10
seconds. Pressing the
“MUTE” button after that will reactivate the audible alerts.
False Detection
This sensor features advanced technology to distinguish between lightning
strikes and interference, however in rare cases the sensor may “false detect”
lightning activity due to interference. In these situations, verify there is
no lightning in the area and then relocate the sensor. If the false detections
persist, identify and relocate the source of interference or relocate the
sensor.
Interference
The sensor features enhanced interference rejection capabilities to prevent
false lightning detection. When the sensor cannot detect lightning due to
interference from nearby equipment, the sensor’s interference indicator will
flash.
- Electric motors (windshield wiper motor or fan motors in cars, hard drive and optical drive motors on your PC and AV equipment, well pumps, sump pumps)
- CRT monitors (PC monitors, TV’s)
- Fluorescent light fixtures (turned off or on)
- Microwave ovens (while in use)
- PC’s and mobile phones
WARNING: Take shelter IMMEDIATELY when lightning is present, whether or not it has been detected by the Lightning Detection Sensor. If you are concerned about lightning strikes, follow all safety precautions to keep yourself and others safe. DO NOT rely on this Lightning Detection Sensor as your only source for warnings about potentially deadly lightning strikes or other severe weather conditions.
OPERATION
Using the Weather Station
Learning Mode
Self-calibrating forecasting uses a unique algorithm to analyze changes in
pressure over a time period (called Learning Mode) to determine your altitude.
After 14 days, the Learning Mode icon disappears from the display screen. At
this point, the self-calibrated pressure is tuned in to your location and the
unit is ready for superior weather prediction.
Weather Forecast
AcuRite’s patented self-calibrating forecasting provides your personal
forecast of weather conditions for the next 12 to 24 hours by collecting data
from the sensor in your backyard. It generates a forecast with pinpoint
accuracy – personalized for your exact location.
Barometric Pressure
Subtle variations in barometric pressure greatly affect the weather. This
weather station displays the current pressure with an arrow icon to indicate
the direction the pressure is trending (FALLING, STEADY, or RISING).
High & Low Records
Today’s high and low records are displayed for indoor and outdoor temperature
and humidity. Today’s records automatically clear at 12:00am midnight every
day.
Press the “Records” button to cycle through high and low recorded values for
outdoor and indoor temperature and humidity.
Troubleshooting
Problem | Possible Solution |
---|
No outdoor sensor reception
no bars
| If the wireless signal indicator shows no bars:
• Relocate the display and/or the outdoor sensor.
The units must be within 330 ft (100 m) of each other.
• Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc.).
• Use standard alkaline batteries (or lithium batteries in sensor when temperature is below -4˚F/-20˚C). Do not use heavy-duty or rechargeable batteries. NOTE: It may take a few minutes for display and sensor to synchronize after batteries are replaced.
Outdoor temperature is flashing or
showing dashes
| Flashing of the outdoor temperature is generally an indication of wireless interference.
1. Bring both the sensor and display indoors and remove batteries from each.
2. Make sure the A-B-C switches on both units match.
3. Reinstall batteries in the outdoor sensor.
4. Reinstall batteries in the display.
5. Let the units sit within a couple feet of each other for a few minutes to gain a strong connection.
Inaccurate forecast
| • Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions.
• Has the icon disappeared from the display? Learning Mode must complete before forecast and pressure will be accurate.
• Allow unit to run continuously for 33 days. Battery removal or resetting the display will restart Learning Mode. After 14 days, forecast should be fairly accurate, however, Learning Mode calibrates for a total of 33 days.
Inaccurate temperature or humidity| • Make sure both the display and sensor are placed out of direct sunlight and away from any heat sources or vents (see page 8).
• Make sure both units are positioned away from moisture sources (see page 8).
Display screen not working
| • Check that the power adapter is plugged into the display and an electrical outlet.
• Reset the display by pressing the reset button, located on the back of the display. Date and time will need to be entered after a reset.
Interference Indicator is flashing| • Relocate the sensor.
• Make sure the sensor is placed at least 3 feet (.9 m) away from electronics that may cause interference (see page 10).
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.acurite.com/support
Care and Maintenance
Display Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Outdoor Sensor Care
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Calibration
The indoor/outdoor temperature and humidity readings, and barometric pressure
can be calibrated on the display to improve accuracy. Calibration can improve
accuracy when sensor placement or environmental factors impact the data
accuracy.
- To access calibration mode, press AND HOLD the “ “ “set” and “ “ buttons simultaneously for at least 5 seconds.
- To adjust the currently selected (flashing) item, press and release the “ “ or “ “ buttons to calibrate the data value higher or lower than the actual reading.
- To save your adjustments, press and release the “set” button to adjust the next preference. The “ ” icon will remain illuminated next to calibrated values.
The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)*
- To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the “set” button for 10 seconds. “manual” will appear above the barometric pressure to indicate that manual mode has been activated. Press and HOLD the “set” button for 10 seconds to return to AUTO mode.
After 10 seconds of inactivity, the display will save the adjustments and exit calibration mode. Note: Calibrations will be erased if the display is reset or if batteries are removed and the power adapter is unplugged.
Specifications
LIGHTNING DETECTION RANGE | 1 – 25 miles / 1.6 – 40km |
---|---|
TEMPERATURE RANGE | Outdoor: -40˚F to 158˚F; -40˚C to 70˚C |
Indoor: 32˚F to 122˚F; 0˚C to 50˚C
HUMIDITY RANGE| Outdoor: 1% to 99% RH
Indoor: 1% to 99% RH
WIRELESS RANGE| 330 ft/100 m depending on home construction materials
OPERATING FREQUENCY| 433 MHz
POWER| Display: 5V, 100mA power adapter
3 x AAA alkaline batteries (optional)
Sensor: 4 x AA alkaline or lithium batteries
DATA REPORTING| Outdoor: 16 second updates
Indoor: 60 second updates
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- (1) This device may not cause interference, and
- (2) This device must accept any interference received, including interference that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and visit acurite.com/support
- Installation Videos
- Instruction Manuals
- Submit Feedback & Ideas
- Register your Product
- Replacement Parts
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection www.acurite.com
/product-registration
Limited 1-Year Warranty
AcuRite is a wholly owned subsidiary of Chaney Instrument Company. For
purchases of AcuRite products, AcuRite provides the benefits and services set
forth herein. For purchases of Chaney products, Chaney provides the benefits
and services set forth herein. We warrant that all products we manufacture
under this warranty are of good material and workmanship and, when properly
installed and operated, will be free of defects for a period of one year from
the date of purchase. Any product which, under normal use and service, is
proven to breach the warranty contained herein within ONE YEAR from date of
sale will, upon examination by us, and at our sole option, be repaired or
replaced by us. Transportation costs and charges for returned goods shall be
paid for by the purchaser. We hereby disclaim all responsibility for such
transportation costs and charges. This warranty will not be breached, and we
will give no credit for products which have received normal wear and tear not
affecting the functionality of the product, been damaged (including by acts of
nature), tampered, abused, improperly installed, or repaired or altered by
others than our authorized representatives. Remedy for breach of this warranty
is limited to repair or replacement of the defective item(s). If we determine
that repair or replacement is not feasible, we may, at our option, refund the
amount of the original purchase price.
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER
WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY
EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF
MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
We expressly disclaim all liability for special, consequential, or incidental
damages, whether arising in tort or by contract from any breach of this
warranty. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply
to you. We further disclaim liability from personal injury relating to its
products to the extent permitted by law. By acceptance of any of our products,
the purchaser assumes all liability for the consequences arising from their
use or misuse. No person, firm or corporation is authorized to bind us to any
other obligation or liability in connection with the sale of our products.
Furthermore, no person, firm or corporation is authorized to modify or waive
the terms of this warranty unless done in writing and signed by a duly
authorized agent of ours. In no case shall our liability for any claim
relating to our products, your purchase or your use thereof, exceed the
original purchase price paid for the product.
Applicability of Policy
This Return, Refund, and Warranty Policy applies only to purchases made in the
United States and Canada. For purchases made in a country other than the
United States or Canada, please consult the policies applicable to the country
in which you made your purchase. Additionally, this Policy applies only to the
original purchaser of our products. We do cannot and do not offer any return,
refund, or warranty services if you buy products used or from resale sites
such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the laws of the United
States and the State of Wisconsin. Any dispute relating to this Policy shall
be brought exclusively in the federal or State courts having jurisdiction in
Walworth County, Wisconsin; and purchaser consents to jurisdiction within the
State of Wisconsin.
www.AcuRite.com
© Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.acurite.com/patents for details.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>