OMEGA DPG110 DC Loop Powered Digital Pressure Gauge Instruction Manual
- June 9, 2024
- Omega
Table of Contents
DC Loop Powered
Digital Pressure Gauge
DPG110
INSTRUCTION SHEET
DPG110 DC Loop Powered Digital Pressure Gauge
Shop online at omega.com e-mail: info@omega.com
For latest product manuals: omegamanual.info
Introduction
DPG110 is digital pressure gauge powered by a seperate loop power supply from
12 to 30VDC. It is made for easy on-site installation. The DPG110 uses a high-
precision piezo-resistive pressure sensor. The output signal is amplified by a
high-precision, low-temperature drift amplifier. The signal is then fed into a
high accuracy A/D converter for the microprocessor to process and then show on
the LED display.
This flexible, simple to operate digital pressure gauge is safe, reliable, and
easy to debug. The DPG110 is widely used in hydropower, water, petroleum,
chemical, mechanical, hydraulic, and other industries.
Features
- 4-20mA interface
- 4-digit 0.56” LED display
- Ceramic pressure sensor core
- Digital Calibration
- Anti-jamming design suitable for electromagnetic and harsh industrial environments.
- IP65 rated outlet port connector
Specifications
-
Measuring Range 0
– 20MPa -
Overload Pressure
150%~200% -
Pressure Type
A/G -
Stability
≤0.2% FS per year -
Power Supply
12-30VDC -
Display
4 digits LED -
Accuracy Range
±0.25% for gauge pressure >5psi ±0.5% FS for all others including absolute, compound gauge, and Vacuum ranges -
IP Rating
IP65 -
Output
4-20mA Signal -
Operating Temp
-30ºC ~ 80ºC -
Relative Humidity
≤90% -
Thread Size
1/4 NPT -
Thread Material
SS316
Dimensions
Control Method
Operating Instructions
-
Wiring
RED: +24VDC
Black: Ground -
Calibration
Press ▼for 5 seconds for zero callibration.
Press ▲ for 5 seconds for full scale calibration
-
Operation panel description:
• The transmitter board provides a three-button and Led display man-machine interface to operate all transmitter Settings and calibration parameters.
• Key functions are multiplexed. A down key is a shift key when the input data is shifted. -
Clear the zero deviation:
• Given zero standard pressure, long press increase button for 10 seconds to calibrate full degree.
• Given full standard pressure, hold down the reduce button for 10 seconds to calibrate zero.
This operation is a shortcut provided to customers, generally not end users do not enter this function to prevent calibration data damage. -
Menu operation, as shown below:
Calibration menu is the transmitter calibration way for factory calibration and general technical supervision department, general users do not enter the setting of any data, non-professionals modify any data may lead to the transmitter completely unable to work.
Circuit board through the panel of the three keys to achieve all the parameters input and calibration data Settings, collection. The circuit board on the meter setting and input to take a variety of optimization measures to improve customer operation speed:
- The decrease key and increase key of the meter have variable speed function
- For the menu that needs to be modified by a large number, the menu that needs to continuously input data adopts the shift mode, and the menu that needs to continuously input data adopts the incremental mode
- The meter will stop analog output in the set state, so if the user does not operate the meter within 3 minutes, it will automatically exit to the measurement state
- The shift input has a flashing prompt function
- The full meter data will flash when it exceeds 120% of the normal setting display value. Less than 0.2% of the zero-setting value, the instrument displays the zero value, which can realize the zero-shielding function of the sensor
- When the meter enters the factory password menu in the state of zero clearance, the zero-clearance value will be automatically cleared when the menu exits
- The meter saves all settings only when it exits the menu normally
The information contained in this document is believed to be correct, but
OMEGA accepts no liability for any errors it contains, and reserves the right
to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be
used for, human applications.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in
materials and workmanship for a period of 13 months from date of purchase.
OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal
one (1) year product warranty to cover handling and shipping time. This
ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation.
OMEGA’s Customer Service Department will issue an Authorized Return (AR)
number immediately upon phone or written request. Upon examination by OMEGA,
if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action
of the purchaser, including but not limited to mishandling, improper
interfacing, operation outside of design limits, improper repair, or
unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result
of excessive corrosion; or current, heat, moisture or vibration; improper
specification; misapplication; misuse or other operating conditions outside of
OMEGA’s control. Components in which wear is not warranted, include but are
not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products.
However, OMEGA neither assumes responsibility for any omissions or errors nor
assumes liability for any damages that result from the use of its products in
accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by the company will be as specified
and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The
remedies of purchaser set forth herein are exclusive, and the total liability
of OMEGA with respect to this order, whether based on contract, warranty,
negligence, indemnification, strict liability or otherwise, shall not exceed
the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall
it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with
any nuclear installation or activity; or (2) in medical applications or used
on humans. Should any Product(s) be used in or with any nuclear installation
or activity, medical application, used on humans, or misused in any way, OMEGA
assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER
language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA
harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST
OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE
DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number
should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and
proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE
contacting OMEGA:
- Purchase Order number under which the product was PURCHASED,
- Model and serial number of the product under warranty, and
- Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
- Purchase Order number to cover the COST of the repair,
- Model and serial number of the product, and
- Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an
improvement is possible. This affords our customers the latest in technology
and engineering. OMEGA is a trademark of OMEGA ENGINEERING, INC.
©Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. This document may
not be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
omega.com
info@omega.com
Servicing North America:
U.S.A. Headquarters:
Omega Engineering, Inc.
Toll-Free: 1-800-826-6342 (USA & Canada
only)
Customer Service: 1-800-622-2378 (USA &
Canada only)
Engineering Service: 1-800-872-9436
(USA & Canada only)
Tel: 203-359-1660
Fax: 203-359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
References
- Omega Engineering | Sensing, Monitoring and Control Solutions
- Global Presence | Omega Engineering
- Omega Engineering | Sensing, Monitoring and Control Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>