aap NANO-Z1 Single Zone Expander Module Instructions

June 9, 2024
AAP

aap NANO-Z1 Single Zone Expander Module

INSTRUCTIONS

  • Single zone expander module for ESL and ESX systems.
  • This device allows you to add detectors directly onto the Elite systems keypad bus.
  • Each device takes up 1 radio zone slot. Multiple devices can be connected on one system.
  • Its small size allows it to be installed inside a PIR.

aap NANO-Z1 Single Zone Expander Module-fig2

Programming

For ESL & Elite-S follow <?> (in Green). For ESX follow <?> (in Red)

Zone Assignment
For a NANO-Z1 to work on the Elite system, you need to select a spare zone slot, Enable it and tell it to be a Radio Zone. This is done at address 122. In Installer mode press <122> then choose the zone

aap NANO-Z1 Single Zone Expander Module-fig3

Note. Zones <9-16> on an ESL are already configured for a NANO-Z1 to be enrolled.

Zone Protocol
The NANO-Z1 communicates in the Freelink/Freewave Protocol. Before you Enroll the device, make sure the protocol is set correctly. This is done at address 127. In Installer mode press <127> then select the zone <1-16><1-64> and , now choose either type <3> or <4> and

aap NANO-Z1 Single Zone Expander Module-fig4

Zone Enrolling
With the NANO-Z1 connected to the Keypad bus, you can now Enroll it into the Zone you have setup.
This is done at address 164. In Installer mode press <164> then select the zone <1-16><1-64> and Now turn Dipswitch 4 On (this should stop the KP beeping)

Recommended Example

aap NANO-Z1 Single Zone Expander Module-fig6