FREDRICK RAMOND FR41027 Inez Medium Pendant Instruction Manual

June 9, 2024
FREDRICK RAMOND

Drawin g 1 – Stem Assembly

FR41027 Inez Medium Pendant

Drawing 2 – Mounting Detail![FREDRICK RAMOND FR41027 Inez Medium Pendant

Mounting Instructions

Item No: FR41027

start here

  1. Find a clear area in which you can work.

  2. Unpack fixture and glass from carton.

  3. Carefully review instructions prior to assembly.

  4. Determine the desired height the pendant will be installed.

  5. The fixture is supplied with assorted stem sizes. Determine what combinations of stems are needed to achieve desired length – see Drawing 1.

  6. Slip stems over wire and thread first stem onto top of pendant, longest stem first. Repeat this process until all required stems are threaded together.

  7. Slip wire through center hole of canopy swivel and thread swivel onto the top of the last stem installed.

  8. To mount assembled pendant body to ceiling, first make all the necessary wiring connections using instruction sheet IS18 provided.

  9. After all wiring connections are complete, tuck all wires into junction box (J) – see Drawing 2.

  10. Now attach mounting strap (A) to junction box (J) using two screws (B) NOT PROVIDED.
    NOTE: the back of mounting strap (A) should be flush against the ceiling. It should not be recessed into the ceiling or off of the ceiling surface.

  11. Next slip canopy (C) up against the ceiling and thread screw collar (S) onto exposed portion of threaded section (L) and tighten to secure canopy to ceiling.

  12. Refer to assembly instructions for attaching glass to pendant body.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (1.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to continue installation of this fixture.
Drawing 3-Shade assemblyFREDRICK RAMOND FR41027 Inez Medium Pendant -
fig 1

  1. Lamp fixture using appropriate E12 base bulb (8)
  2. Secure threaded nipple (3) to coupler in socket cluster (2)
  3. Secure top nipple (15) to coupler (14)
  4. Slide cover (13) over top nipple (15)
  5. Slide tube (4) over nipple (3)
  6. Place end cap (5), metal washer (6) and plastic washer (7) on the end of the nipple (3)
  7. Lift shade (9) up towards assembly. The hole in the bottom of the shade should pass though nipple (3)
  8. Place metal washer (1) underneath shade (9)and use hex nut (12) to secure shade
  9. Next place bottom cover (10) over hex nut and secure with finial (11)
  10. Fixture can now be powered on

Drawing 1 – Flush Mount

Drawing 2 – Chain Hung

Drawing 3 – Post-Mount

I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – – – see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw. Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

HINKLEY 33000 Pin Oak Parkway,
Avon Lake, OH 44012 800.446.5539 / 440.653.5500
hinkley.com
A Division of Hinkley Lighting, Inc. 33000
PIN OAK PARKWAY I AVON LAKE, OHIO 44012 toll free 800.446.5539 I
phone 440.653.5500

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FREDRICK RAMOND User Manuals

Related Manuals