Operating Instructions
WARNING! Not for children under three years. Choking hazard – small parts. Contains functional sharp edges and points!
General Warnings
- Choking hazard — This product contains small parts that could be swallowed by children. This poses a choking hazard.
- Risk of electric shock — This device contains electronic components that operate via a power source (batteries). Only use the device as described in the manual, otherwise you run the risk of an electric shock.
- Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion.
- Risk of chemical burn — Make sure you insert the batteries correctly. Empty or damaged batteries could cause burns if they come into contact with the skin. If necessary, wear adequate gloves for protection.
- Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately with a plenty of water and seek medical attention.
- Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. Remove the batteries from the unit if itis not to be used for a long period of time, or if the batteries are empty!
- Never recharge normal, nonchargeable batteries. This could lead to explosion during the charging process.
- Rechargeable batteries are only to be charged under adult supervision.
- Rechargeable batteries are to be removed from the toy before being charged
- The terminals must not be short-circuited.
- Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.
- Tools with sharp edges are often used when working with this device. Because there is a risk of injury from such tools, store this device and all tools and accessories in a location that is out of the reach of children.
- Keep instructions and packaging as they contain important information.
EC Declaration of Conformity
Bressler GmbH has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/download/8852000/ CE/8852000_CE.pdf
UKCA Declaration of Conformity
Bressler GmbH has issued a „Declaration of Conformity“ in accordance with
applicable guidelines and corresponding standards. The full text of the UKCA
declaration of conformity is available at the following internet address:
www.bresser.de/download/8852000/
CE/8852000_CE.pdf
Bresser UK Ltd.
- Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain
Your microscope is made up of the following parts (Fig. 1-4):
- Binocular view piece (with eyepiece supports)
- Stereo objective
- Eyepieces
- Illumination (LED)
- Microscope stage (with object plate)
- Stage clips
- Focus knob
- On/off switch
- Battery compartment
- Mounting screws
- Battery contacts (flat sheets and spring terminals)
- Diffusion cap
Location
Before you start, choose an ideal location for using your microscope. It is important that you have enough light available (window, desk lamp).
Simple Observation
Place the object to be observed (for example, a rock) in the middle of the microscope stage (5). When the object is large enough, it is best to fix it in place with the stage clips (6). Now, take a look through the binocular eye lens (1) and change the distance of the eyepiece (3), so that you have a circular, clear image. The sharpness is adjusted by slowly turning the focus knob (7).
Illumination
Turn off the illumination (4) with the On/Off switch (8). Remove both eyepieces (3) from the eyepiece supports (1) and turn the entire microscope over. In the base of the microscope there is a battery compartment (9). Loosen the 6 fixing screws (10) of the battery compartment cover and remove the cover. Place the batteries (2x AA) in the compartment so that the flat minus poles (-) press against the spring terminal and the plus poles (+) are touching the flat contact sheets (11). Put on the cover and fix it with the 6 screws (10). Turn the microscope overagain. Place the eyepieces back on. You can not turn on the light (4) with the on/off switch (8) on the base of the microscope.
TIPS on cleaning
Remove the device from it’s energy source before cleaning (remove plug from socket / remove batteries).
Clean the exterior of device with a dry cloth. Do not use cleaning fluids so
as to avoid causing damage to electronic components.
Protect the device from dust and moisture. Store the device in the bag
supplied or in its original packaging. Batteries should be removed from the
device if it is not going to be used for a long period of time.
Clean the lens (objective and eyepiece) only with the cloth supplied or some
other soft lint-free cloth (e.g. micro-fibre). Do not use excessive
pressure – this may scratch the lens. Dampen the cleaning cloth with a
spectacle cleaning fluid and use it on very dirty lenses.
DISPOSAL
Dispose of the packaging material/s as legally required. Consult the local authority on the matter if necessary.
Do not dispose of electrical equipment in your ordinary refuse. The European guideline 2002/96/EU on Electronic and Electrical Equipment Waste and relevant laws applying to it require such used equipment to be separately collected and recycled in an environment-friendly manner.
Empty batteries and accumulators must be disposed of separately. Information
on disposing of all such equipment made after 01 June 2006 can be obtained
from your local authority.
In accordance with the regulations concerning batteries and rechargeable
batteries, disposing of them in the normal household waste is explicitly
forbidden. Please pay attention to dispose of your used batteries as required
by law – at a local collection point or in the retail market (a disposal in
domestic waste violates the Battery Directive).
Batteries that contain toxins are marked with a sign and a chemical symbol.
„Cd“ = cadmium, „Hg“ = mercury, „Pb“ = lead.
-
battery contains cadmium
-
battery contains mercury
-
battery contains lead
Contact
Germany
www.bresser.de
@BresserEurope
Bresser UK Ltd.
Suite 3G, Eden House
Enterprise Way, Edenbridge,
Kent TN8 6HF, Great Britain
Documents / Resources
|
BRESSER 8852000 Optical Stereo
Microscope
[pdf] Instruction Manual
8852000, Optical Stereo Microscope, Stereo Microscope, Optical Microscope,
Microscope, 8852000 Microscope
---|---
References
- konsoleH :: Login
- index · powered by h5ai 0.26.1 (http://larsjung.de/h5ai/)
- Bresser | Downloads | Expand Your Horizon
- Bresser | FAQ | Expand Your Horizon
- Bresser | Ratgeber | Expand Your Horizon
- Bresser | BRESSER JUNIOR 20x Auflicht-Mikroskop | Expand Your Horizon
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>