Q-TRAN Q-CAP Flexible Fixtures Installation Guide

June 9, 2024
Q-TRAN

Q-TRAN Q-CAP Flexible Fixtures

INSTALLATION

VHB MOUNTING

  1. Remove the backing from the adhesive and apply firm pressure to the bonding surface.
  2. Peel off secondary backing.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-1
  3. Adhere to mounting surface.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-2

WHITE SNUG CLIP

NOTE: White snug clip should be placed every 12″

INCLUDED HARDWARE

  • 4×5/8″ Flat head screw

  1. Mount white snug clip with provided flat head screw.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-5
  2. Align fixture to white snug clips matching distances.
  3. Press fixture into white snug clips.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-6

PVC MOUNT CLIP: Connects two seamless fixtures, with or without wire exit

MICRO5-PPS-2

Mounting Feed

  1. Press both fixtures into PPS clip.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-8
  2. Snap fixture into mounted PPS channel When wire will exit into conduit do not install bracket.
  3. Finished Assembly for seamless bottom feed mounting (S5/P5).Q-TRAN-Q-CAP-Flexible-Fixtures-fig-9

LOW PROFILE PVC MOUNT CLIP: Connects two seamless fixtures, with or without wire exit.

MICRO5-PPS-LP-2

Mounting Feed

  1. Snap in 2″ channel
  2. Press in fixturesQ-TRAN-Q-CAP-Flexible-Fixtures-fig-11
  3. Finished assembly for end feed mounting (S1/P1).Q-TRAN-Q-CAP-Flexible-Fixtures-fig-12

PVC MOUNT CHANNEL: Support for the fixture

MICRO5-PPS-96 & MICRO5-PPS-FT

  • 96″ (PPS-96) or custom length (PPS-FT)Q-TRAN-Q-CAP-Flexible-Fixtures-fig-13

Built in wire way

  • The PPS-BRACKET allows you to create a wire way under the PPS channel without any screws interfering

Millwork install

  1. The PPS-BRACKET can be field cuttable and cut to whatever length your application requires. The PPS-BRACKET can be installed as a full length of 96″, multiple smaller pieces, or end to end for longer seamless runs.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-16
  2. Using pre-drilled pilot holes screw the #6 flat head screws to mount the PPS-BRACKET (1 screw every 16″).
    • NOTE : For drywall applications mount directly into a stud.
  3. Using pre-drilled pilot holes, use the #6 flat head screws to mount the PPS-BRACKET.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-17
  4. The PPS-96 or PPS-FT can be field cuttable and cut to whatever length your application requires. The PPS-96 or PPS-FT can be installed as a full length of 96″, multiple smaller pieces, or end to end for longer seamless runs.
  5. To mount, pinch the upper half of the PPS-96 or PPS-FT while you pivot it around one side of the PPS-BRACKET and push-in until you hear it snap into place. The PPS-96 or PPS-FT flexes around the PPS-BRACKET to create a solid, and secure snap on connection.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-18

LOW PROFILE PVC MOUNT CHANNEL: Support for the fixture

MICRO5-PPS-LP-96 & MICRO5-PPS-LP-FT

96″ (PPS-96) or custom length (PPS-FT)

  1. The PPS-LP-96 or PPS-LP-FT can be field cuttable and cut to whatever length your application requires. The PPS-96 or PPS-FT can be installed as a full length of 96″, multiple smaller pieces, or end to end for longer seamless runs.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-20

  2. Drill holes (1 hole/screw every 16″) into the PPS-LP.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-21

  3. Using pre-drilled holes, use the #6 flat head screws to mount the PPS-LP.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-22
    NOTE : For drywall applications mount directly into a stud.

  4. Snap fixture into PPS-LP.Q-TRAN-Q-CAP-Flexible-Fixtures-fig-23