CZONE Motor Output Interface Installation Guide
- June 8, 2024
- CZONE
Table of Contents
Motor Output Interface
Installation Guide
Motor Output Interface
Copyright
This document is copyright 2018 under the Creative Commons agreement. Rights
are granted to research and reproduce elements of this document for non-
commercial purposes on the condition that BEP Marine is credited as the
source. Electronic re-distribution of the document in any format is
restricted, to maintain quality and version control.
Important
BEP Marine strives to ensure all information is correct at the time of
printing. However, the company reserves the right to change without notice any
features and specifications of either its products or associated
documentation.
Translations: In the event that there is a difference between a
translation of this manual and the English version, the English version should
be considered the official version. It is the owner’s sole responsibility to
install and operate the device in a manner that will not cause accidents,
personal injury or property damage.
Use of This Manual
Copyright © 2018 BEP Marine LTD. All rights reserved.
Reproduction, transfer,
distribution or storage of part or all of the contents in this document in any
form without the prior written permission of BEP Marine is prohibited.
This
manual serves as a guideline for the safe and effective operation, maintenance
and possible correction of minor malfunctions of the Output Interface Module.
GENERAL INFORMATION
USE OF THIS MANUAL
Copyright © 2016 BEP Marine. All rights reserved.
Reproduction, transfer,
distribution or storage of part or all of the contents in this document in any
form without the prior written permission of BEP Marine is prohibited.
This
manual serves as a guideline for the safe and effective operation, maintenance
and possible correction of minor malfunctions of the Motor Output Interface,
called MOI further in this manual.
This manual is valid for the following models:
Description | Part number |
---|---|
CZONE MOI C/W CONNECTORS | 80-911-0007-00 |
CZONE MOI C/W CONNECTORS | 80-911-0008-00 |
It is obligatory that every person who works on or with the MOI is completely
familiar with the contents of this manual, and that he/she carefully follows
the instructions contained herein.
Installation of, and work on the MOI, may be carried out only by qualified,
authorized and trained personnel, consistent with the locally applicable
standards and taking into consideration the safety guidelines and measures
(chapter 2 of this manual). Please keep this manual in a secure place!
GUARANTEE SPECIFICATIONS
BEP Marine guarantees that this unit has been built according to the legally
applicable standards and specifications. Should work take place which is not
in accordance with the guidelines, instructions and specifications contained
in this
Installation manual, then damage may occur and/or the unit may not fulfil its
specifications. All of these matters may mean that the guarantee becomes
invalid.
QUALITY
During their production and prior to their delivery, all of our units are
extensively tested and inspected. The standard guarantee period is two years.
VALIDITY OF THIS MANUAL
All of the specifications, provisions and instructions contained in this
manual apply solely to standard versions of the Combined Output Interface
delivered by BEP Marine.
LIABILITY
BEP can accept no liability for:
- Consequential damage due to use of the MOI. Possible errors in the manuals and the results thereof CAREFUL! Never remove the identification label
Important technical information required for service and maintenance can be
derived from the type number plate.
CHANGES TO THE MOTOR OUTPUT INTERFACE
Changes to the MOI may be carried out only after obtaining the written
permission of BEP.
SAFETY AND INSTALLATION PRECAUTIONS
WARNINGS AND SYMBOLS
Safety instructions and warnings are marked in this manual by the following
pictograms:
CAUTION
Special data, restrictions and rules with regard to preventing damage.
WARNING
A WARNING refers to possible injury to the user or significant material damage
to the MOI if the user does not (carefully) follow the procedures.
NOTE
A procedure, circumstance, etc, which deserves extra attention.
USE FOR INTENDED PURPOSE
-
The MOI is constructed as per the applicable safety-technical guidelines.
-
Use the MOI only:
• In technically correct conditions
• In a closed space, protected against rain, moisture, dust and condensation
• Observing the instructions in the installation manual
WARNING Never use the MOI in locations where there is danger of gas or dust explosion or potentially flammable products! -
Use of the MOI other than mentioned in point 2 is not considered to be consistent with the intended purpose. BEP Marine is not liable for any damage resulting from the above.
ORGANIZATIONAL MEASURES
The user must always:
- Have access to the user’s manual and be familiar with the contents of this manual
MAINTENANCE AND REPAIR
- Switch off supply to the system
- Be sure that third parties cannot reverse the measures taken
- If maintenance and repairs are required, only use original spare parts
GENERAL SAFETY AND INSTALLATION PRECAUTIONS
- Connection and protection must be done in accordance with local standards
- Do not work on the MOI or system if it is still connected to a power source. Only allow changes in your electrical system to be carried out by qualified electricians
- Check the wiring at least once a year. Defects such as loose connections, burned cables, etc. must be corrected immediately
OVERVIEW
DESCRIPTION
The Motor Output Interface (MOI) has an output pair for controlling DC motors
which require a reversal of polarity to change the direction of their
mechanical operation. For example, a DC motor for an electric window mechanism
will move the window up or down depending on the polarity of the feed to the
motor. The MOI also incorporates two standard output channels such as is found
on the Output Interface. Connection to the unit is simple: a large 6 way plug
allows connections to cables of up to 16 mm2 (6AWG) in size, or multiple
smaller conductors. No need for specialized crimp terminals and expensive
crimp tools to be carried for terminations to CZone, just a blade screwdriver.
A protective flexible boot offers protection to the connections from harsh
environment conditions.
FEATURES
- 4 levels of backup fusing including manual override (as required by ABYC)
- Multiple channels can be bridged together to offer higher current switching
- Power consumption 12 V: 85 mA (standby 60 mA)
- Dimensions, WxHxD: 7-29/32″x5″x1-3/4″ 200x128x45 mm
- Small, non metallic, easy to install case
- 2 x 20 amps circuits
- 1 x 20A “H Bridge” output for controlling direction of DC motors through polarity change
- IPX5 water ingress protection
- Programmable software fuse sizes
MOI HARDWARE OVERVIEW
1. DC Power LED | 8. Motor Circuit Fuses |
---|---|
2. Waterproof Cover | 9. MOI Input/Output Fuse Label |
3. Circuit ID Labels | 10. DC Output Connector |
4. Protective Boot | 11. Output Circuit Fuses |
5. Channel Status LEDs | 12. Dipswitch |
6. Network Status LED | 13. NMEA 2000 Connector |
7. Module ID Label |
LED INDICATORS 1. DC Power LED
Colour | Description |
---|---|
Extinguished | Network Power Disconnected |
Green | Input Power Available |
Red | Input Power Reverse Polarity |
2. Channel Status LED Indicators
Colour | Description |
---|---|
Extinguished | Channel Off |
Green Solid On 1 Red Flash | Channel On |
1 Red Flash | Module Not Configured |
2 Red Flash | Configuration Conflict |
3 Red Flash | DIP Switch Conflict |
4 Red Flash | Memory Failure |
5 Red Flash | No Modules Detected |
6 Red Flash | Low Run Current |
7 Red Flash | Over Current |
8 Red Flash | Short Circuit |
9 Red Flash | Missing Commander |
10 Red Flash | Reverse Current |
11 Red Flash | Current Calibration |
3. Network Status LED Indicator
Colour | Description |
---|---|
Extinguishe | Network Power Disconnected |
Green | Network Power Connected |
Red Flash | Network Traffic |
DESIGN
- Ensure load being H-Bridged is capable of being controlled via polarity change.
- Load must be under 20amps current draw.
- Make a list of outputs to be wired to the MOI and assign them to one of the 2 output channels.
- Ensure all cables are appropriately rated for each assigned load.
- Output connector accepts cable gauges 24AWG – 8AWG (0.5 – 6mm).
- Ensure power supply cable to the MOI is appropriately rated for the maximum continuous current of all loads and is fused appropriately to protect the cable.
- Ensure continuous current draw of each connected load does not exceed maximum channel rating of 20A.
- Install the appropriately rated fuses for each channel.
- Loads exceeding 20A will require paralleling 2 channels together.
INSTALLATION
THINGS YOU NEED
- Electrical tools
- Wiring and fuses
- Motor Output Interface Module
- 4 x 8G or 10G (4mm or 5mm) self-tapping screws or bolts for mounting the MOI
ENVIRONMENT
Obey the following stipulations during installation:
- Ensure the MOI is located in an easily accessible location and indicator LED’s are visible.
- Ensure there is enough clearance above the MOI to allow the cover to be removed.
- Ensure there is at least 10mm clearance around the sides and top of the MOI.
- Ensure the MOI is mounted on a vertical flat surface.
- Ensure there is sufficient space for the wires to exit the product.
MOUNTING
-
Mount the MOI on a vertical surface with the cables exiting downwards.
-
Allow enough space below cable grommet for wiring bend radius.
Note – Cable radius determined by wiring manufacturer. -
Fasten the MOI by using 4 x 8G or 10G (4mm or 5mm) self-tapping screws or bolts (not supplied).
IMPORTANT – The MOI must be mounted within 30 degrees from the vertical
position to ensure water correctly runs away from the product if mounted in a
location where water can contact the product.
CONNECTIONS
The MOI has a convenient output connector that requires no crimping tools
and accepts cables from 24AWG to 8AWG (0.5 – 6mm). The unit has no power key
and will turn on when power is applied to the network. The module will
continue to draw power even when it is not in operation. It is recommended
that a battery isolator switch is installed for when the system is not in use.
- Feed output wires through cable grommet
- Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten screws to 4.43 in/lbs (0.5NM).
- Insert plug firmly into module and tighten 2x retaining screws.
- Connect a NMEA2000 drop cable from the NMEA2000 backbone (do not power up network yet).
IMPORTANT – The positive cable must be sufficient size to carry the
maximum current of all loads connected to the MOI. It is recommended to have a
fuse/circuit breaker rated to protect the cable.
INSERTING FUSES
The MOI provides ignition protected circuit protection for each individual
channel via standard ATC fuses (not supplied). Appropriately rated fuses
should be selected and installed for each channel to protect the load and the
wiring for each circuit.
- Select the appropriate fuse rating for each individual circuit.
- Insert the correctly rated fuses into the NORMAL (bottom) position of all circuits.
- The ATC fuse should be rated to protect the connected load and the wiring from the MOI to the load and also the ground wire.
MECHANICAL BYPASS
The MOI includes a mechanical bypass feature on each of the 2 output channels
for redundancy purposes. Moving any fuse to the BYPASS (top) position will
supply constant battery power to that output. See below diagram showing
circuit #2 in the BYPASS position. NOTE – MOI does not have circuit bypass
on the H-Bridge Channel.
WARNING – Ensure area is free of explosive gasses before
removing/replacing fuses or placing fuses in the bypass position as sparks may
occur.
NETWORK CONFIGURATION
CZone modules communicate with each other over a NMEA2000 CAN BUS network.
Each module needs a unique address, this is achieved by carefully setting the
dipswitch on each module with a small screwdriver. The dipswitch on each
module must match the setting in the CZone configuration. Refer to CZone
Configuration Tool Manual on instructions on creating and editing a CZone
configuration.
- To install the MOI with other networked CZone modules, or to achieve advanced functionality such as timers, load shedding or one touch Modes of operation, a custom configuration needs to be installed.
- Set the dipswitch on the MOI to match the configuration file.
- All other CZone modules must have the dipswitch set to same as the configuration file. The example below shows a dipswitch setting of 01101100 where 0 = OFF and 1 = ON
IMPORTANT – Each CZone device must have a unique dipswitch number and the
dipswitch of the device must match the dipswitch set in the configuration
file.
CIRCUIT IDNETIFICATION LABELS
Standard BEP circuit breaker panel labels are used to indicate the circuit
name for each output
MODULE IDENTIFICATION LABEL
These labels allow easy identification of each module whilst recording the
dipswitch setting. These labels are to be fitted to the cover and to the
module (this prevents covers being swapped). To record the module type and
dipswitch settings use a permanent marker and strike through the applicable
boxes (a strike through on a dipswitch box indicates that switch is on). FIT
THE COVER
- Slide the cable gland up the output wires ensuring it is correctly seated.
- Firmly push the top cover on to the MOI until you hear it click into pace on each side.
- Ensure the cable gland is still correctly in place.
- Install circuit labels if you have purchased a label sheet.
WARNING! The MOI is only ignition protected with the cover correctly
installed.
INITIAL POWER UP
- Power up the NMEA2000 Network, system will flash all outputs for a short time while booting.
- Check that the Network Status LED lights up. It may also be flashing if other devices are on the network and transmitting data.
- Turn the switch/circuit breaker on supplying power to the input stud (if fitted).
- Check the software version on the MOI with the CZone Configuration Tool and update if necessary.
- Write the configuration file to the network (Refer to the CZone Configuration Tool Instructions for details on how to write a CZone configuration file).
- Test all outputs for correctly configured functionality.
- Check the circuit status LED’s for each individual circuit. Refer to LED codes to diagnose any faults which need to be rectified.
SYSTEM DIAGRAM EXAMPLES
ORDERING INFORMATION
Part Numbers and Accessories
Part Number | Description |
---|---|
80-911-0007-00 | CZONE MOI C/W CONNECTORS |
80-911-0008-00 | CZONE MOI NO CONNECTORS |
80-911-0041-00 | TERM BLOCK OI 6W PLUG 10 16 PITCH |
80-911-0034-00 | SEAL BOOT for CZONE OI 6W CONN BK SILICON |
SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Technical Specification
Circuit protection| ATC Fuse with Blown Fuse Alarms
NMEA2000 connectivity| 1 x CAN Micro-C port
Output wire range| 0.5 – 6mm (24AWG – 8AWG)
Output channels| 1x 20A H-Bridge channel 12/24, 2 x 20A Output channels 12/24V
Maximum current| 60A Total Module Current
Dimming| Output channels, PWM @100Hz
Power supply| M6 (1/4″) Positive Terminal (9-32V)
Network Supply voltage| 9-16V via NMEA2000
Circuit bypass| Mechanical Fuse Bypass on all Channels
Ingress protection| IPx5 (mounted vertical on bulkhead and flat)
Compliance| CE, ABYC, NMEA, ISO8846/SAEJ1171 Ignition Protected
Power consumption max| 85mA @12V
Power consumption standby| 60mA @12V
Warranty period| 2 years
Operating temperature range| -15C to +55C (-5F to +131F)
Storage temperature range| -40C to +85C (-40F to +185F)
Dimensions W x H x D| 202.5 x 128.5 x 45mm (7.97 x 5.06 x 1.77”)
Weight| 609g
EMC RATINGS
- IEC EN 60945
- IEC EN 61000
- FCC Class B
- ISO 7637 – 1 (12V Passenger cars and light commercial vehicles with nominal 12 V supply voltage – Electrical transient conduction along supply lines only)
- ISO 7637 – 2 (24V Commercial vehicles with nominal 24 V supply voltage – Electrical transient conduction along supply lines only)
- IEC Standards for indirect lighting strikes
DIMENSIONS Declaration of Conformity
EU declaration of conformity
Name and address of the manufacturer. | BEP marine Ltd |
---|
This declaration of conformity is issued under the sole responsibility of the
manufacturer.
Object of Me declaratan:
Czone MOI (Motor Output Interface)
The object of the declaration described above is in conformity with the
relevant Union harmonisation legislation:
- 2011/65/EU (RoHS directive)
- 2013/53/EU (Recreational Craft Directive)
- 2014/30/EU (Electromagnetic Compatibility Directive)
References to the relevant harmonised standards used Of references to the other technical specificaticos in relation to which conformay IS declared:
- EN 60945:2002 Maritime navigation and radiocommunication equipment and systems
- ISO 8846:2017 Small craft — Electrical devices — Protection against ignition of surrounding flammable gasses (ISO 8846:1990) EU Type Examination certificate # HPiVS/R1217-004-1-01
Read User Manual Online (PDF format)