CZONE Output Interface (OI) Connector & Protective Boot Instruction Manual

June 3, 2024
CZONE

CZONE Output Interface (OI) Connector & Protective Boot

Copyright
This document is copyright 2018 under the Creative Commons agreement. Rights are granted to research and reproduce elements of this document for non- commercial purposes on the condition that BEP Marine is credited as the source. Electronic re-distribution of the document in any format is restricted, to maintain quality and version control.

Important
BEP Marine strives to ensure all information is correct at the time of printing. However, the company reserves the right to change without notice any features and specifications of either its products or associated documentation.
Translations: In the event that there is a difference between a translation of this manual and the English version, the English version should be considered the official version.
It is the owner’s sole responsibility to install and operate the device in a manner that will not cause accidents, personal injury or property damage.

Use of This Manual
Copyright © 2018 BEP Marine LTD. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission of BEP Marine is prohibited. This manual serves as a guideline for the safe and effective operation, maintenance and possible correction of minor malfunctions of the Output Interface Module.

GENERAL INFORMATION

USE OF THIS MANUAL

Copyright © 2016 BEP Marine. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission of BEP Marine is prohibited. This manual serves as a guideline for the safe and effective operation, maintenance and possible correction of minor malfunctions of the Output Interface, called OI further in this manual.

This manual is valid for the following models:

Description Part number
CZONE OI C/W CONNECTORS 80-911-0009-00
CZONE OI NO CONNECTORS 80-911-0010-00

It is obligatory that every person who works on or with the OI is completely familiar with the contents of this manual, and that he/she carefully follows the instructions contained herein.
Installation of, and work on the OI, may be carried out only by qualified, authorized and trained personnel, consistent with the locally applicable standards and taking into consideration the safety guidelines and measures (chapter 2 of this manual). Please keep this manual in a secure place!

GUARANTEE SPECIFICATIONS

BEP Marine guarantees that this unit has been built according to the legally applicable standards and specifications. Should work take place which is not in accordance with the guidelines, instructions and specifications contained in this Installation manual, then damage may occur and/or the unit may not fulfil its specifications. All of these matters may mean that the guarantee becomes invalid.

QUALITY

During their production and prior to their delivery, all of our units are extensively tested and inspected. The standard guarantee period is two years.

VALIDITY OF THIS MANUAL

All of the specifications, provisions and instructions contained in this manual apply solely to standard versions of the Combined Output Interface delivered by BEP Marine.

LIABILITY

BEP can accept no liability for:

  • Consequential damage due to use of the OI. Possible errors in the manuals and the results thereof

CAREFUL! Never remove the identification label
Important technical information required for service and maintenance can be derived from the type number plate.

CHANGES TO THE OUTPUT INTERFACE

Changes to the OI may be carried out only after obtaining the written permission of BEP.

SAFETY AND INSTALLATION PRECAUTIONS

WARNINGS AND SYMBOLS

CAUTION
Special data, restrictions and rules with regard to preventing damage.

WARNING
A WARNING refers to possible injury to the user or significant material damage to the OI if the user does not (carefully) follow the procedures.

A procedure, circumstance, etc, which deserves extra attention.

USE FOR INTENDED PURPOSE
  1. The OI is constructed as per the applicable safety-technical guidelines.

  2. Use the OI only:
    • In technically correct conditions
    • In a closed space, protected against rain, moisture, dust and condensation
    • Observing the instructions in the installation manual
    WARNING Never use the OI in locations where there is danger of gas or dust explosion or potentially flammable products!

  3. Use of the OI other than mentioned in point 2 is not considered to be consistent with the intended purpose. BEP Marine is not liable for any damage resulting from the above.

ORGANIZATIONAL MEASURES

The user must always:

  • Have access to the user’s manual and be familiar with the contents of this manual
MAINTENANCE AND REPAIR
  • Switch off supply to the system
  • Be sure that third parties cannot reverse the measures taken
  • If maintenance and repairs are required, only use original spare parts
GENERAL SAFETY AND INSTALLATION PRECAUTIONS
  • Connection and protection must be done in accordance with local standards
  • Do not work on the OI or system if it is still connected to a power source. Only allow changes in your electrical system to be carried out by qualified electricians
  • Check the wiring at least once a year. Defects such as loose connections, burned cables, etc. must be corrected immediately

OVERVIEW

DESCRIPTION

The Output Interface (OI) provides an intelligent replacement for traditional circuit breaker and fuse panels. It has 6x high power, robust output channels which provide the power supply, control and fusing for a circuit as well as integrating many other built in features such as timers and dimmers. Connection to the unit is simple: a large 6 way plug allows connections to cables of up to 16 mm2 (6AWG) in size, or multiple smaller conductors. No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone, just a blade screwdriver. A protective flexible boot offers protection to the connections from harsh environment conditions.

FEATURES
  • 4 levels of backup fusing including manual override (as required by ABYC)
  • Multiple channels can be bridged together to offer higher current switching
  • Power consumption 12 V: 85 mA (standby 60 mA)
  • Dimensions, WxHxD: 7-29/32″x5″x1-3/4″ 200x128x45 mm
  • Small, non metallic, easy to install case
  • 6 x 20 amps circuits
  • IPX5 water ingress protection
  • Programmable software fuse sizes
OI HARDWARE OVERVIEW
  1. Circuit Status Indicators
  2. Waterproof Cover
  3. Circuit ID Labels
  4. Protective Boot
  5. Network Status Indicator
  6. Module ID Label
  7. Output Fuse Label
  8. DC Positive Stud
  9. DC Output Connector
  10. Circuit Fuses
  11. Dipswitch
  12.  NMEA 2000 Connector

    Output Interface \(OI\) Connector & Protective Boot Oi Hardware
Overview
LED INDICATORS

Channel Status LED Indicators

Colour Description
Extinguished Channel Off
Green Solid On Channel On
1 Red Flash Module Not Configured
2 Red Flash Configuration Conflict
3 Red Flash DIP Switch Conflict
4 Red Flash Memory Failure
5 Red Flash No Modules Detected
6 Red Flash Low Run Current
7 Red Flash Over Current
8 Red Flash Short Circuit
9 Red Flash Missing Commander
10 Red Flash Reverse Current
11 Red Flash Current Calibration

Network Status LED Indicator

Colour Description
Extinguished Network Power Disconnected
Green Network Power Connected
Red Flash Network Traffic

DESIGN

  • Make a list of all outputs to be wired to the OI and assign each of them to one of the 6 channels.
  • Ensure all cables are appropriately rated for each assigned load.
  • Output connector accepts cable gauges 24AWG – 8AWG (0.5 – 6mm).
  • Ensure power supply cable to the OI is appropriately rated for the maximum continuous current of all loads and is fused appropriately to protect the cable.
  • Ensure continuous current draw of each connected load does not exceed maximum channel rating of 20A.
  • Ensure the maximum continuous current of all loads does not exceed the 100A total module current.
  • Install the appropriately rated fuses for each channel.
  • Loads exceeding 20A will require paralleling 2 channels together

INSTALLATION

THINGS YOU NEED
  • Electrical tools
  • Wiring and fuses
  • Output Interface Module
  • 4 x 8G or 10G (4mm or 5mm) self-tapping screws or bolts for mounting the OI
ENVIRONMENT

Obey the following stipulations during installation:

  • Ensure the OI is located in an easily accessible location and indicator LED’s are visible.
  • Ensure there is enough clearance above the OI to allow the cover to be removed.
  • Ensure there is at least 10mm clearance around the sides and top of the OI.
  • Ensure the OI is mounted on a vertical flat surface.
  • Ensure there is sufficient space for the wires to exit the product.
MOUNTING

  1. Mount the OI on a vertical surface with the cables exiting downwards.

  2. Allow enough space below cable grommet for wiring bend radius.
    Note – Cable radius determined by wiring manufacturer.

  3. Fasten the OI by using 4 x 8G or 10G (4mm or 5mm) self-tapping screws or bolts (not supplied).

IMPORTANT – The OI must be mounted within 30 degrees from the vertical position to ensure water correctly runs away from the product if mounted in a location where water can contact the product.

CONNECTIONS

The OI has a convenient output connector that requires no crimping tools and accepts cables from 24AWG to 8AWG (0.5 – 6mm). The unit has no power key and will turn on when power is applied to the network. The module will continue to draw power even when it is not in operation. It is recommended that a battery isolator switch is installed for when the system is not in use.

  1. Feed output wires through cable grommet
  2. Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten screws to 4.43 in/lbs (0.5NM).
  3. Insert plug firmly into module and tighten 2x retaining screws.
  4. Connect a NMEA2000 drop cable from the NMEA2000 backbone (do not power up network yet).
  5.  Connect the appropriate size power supply cable to the M6 positive stud and tighten to 35 in/lbs (4NM), ensuring washers are installed as per diagram.

IMPORTANT – The positive cable must be sufficient size to carry the maximum current of all loads connected to the OI. It is recommended to have a fuse/circuit breaker rated to protect the cable.

INSERTING FUSES

The OI provides ignition protected circuit protection for each individual channel via standard ATC fuses (not supplied). Appropriately rated fuses should be selected and installed for each channel to protect the load and the wiring for each circuit.

  1. Select the appropriate fuse rating for each individual circuit.
  2. Insert the correctly rated fuses into the NORMAL (bottom) position of all circuits.
  3. The ATC fuse should be rated to protect the connected load and the wiring from the OI to the load and also the ground wire.
MECHANICAL BYPASS

The OI includes a mechanical bypass feature for redundancy purposes. Moving any fuse to the BYPASS (top) position will supply constant battery power to that output. See below diagram showing circuit #3 in the BYPASS position.

WARNING – Ensure area is free of explosive gasses before removing/replacing fuses or placing fuses in the bypass position as sparks may occur.

NETWORK CONFIGURATION

CZone modules communicate with each other over a NMEA2000 CAN BUS network. Each module needs a unique address, this is achieved by carefully setting the dipswitch on each module with a small screwdriver. The dipswitch on each module must match the setting in the CZone configuration. Refer to CZone Configuration Tool Manual on instructions on creating and editing a CZone configuration.

  • To install the OI with other networked CZone modules, or to achieve advanced functionality such as timers, load shedding or one touch Modes of operation, a custom configuration needs to be installed.
  • Set the dipswitch on the OI to match the configuration file.
  • All other CZone modules must have the dipswitch set to same as the configuration file.

The example below shows a dipswitch setting of 01101100 where 0 = OFF and 1 = ON

IMPORTANT – Each CZone device must have a unique dipswitch number and the dipswitch of the device must match the dipswitch set in the configuration file.

CIRCUIT IDENTIFICATION LABELS

Standard BEP circuit breaker panel labels are used to indicate the circuit name for each output.

MODULE IDENTIFICATION LABEL

These labels allow easy identification of each module whilst recording the dipswitch setting. These labels are to be fitted to the cover and to the module (this prevents covers being swapped). To record the module type and dipswitch settings use a permanent marker and strike through the applicable boxes (a strike through on a dipswitch box indicates that switch is on).

FIT THE COVER
  1. Slide the cable gland up the output wires ensuring it is correctly seated.
  2. Firmly push the top cover on to the OI until you hear it click into pace on each side.
  3. Ensure the cable gland is still correctly in place.
  4. Install circuit labels if you have purchased a label sheet.

WARNING! The OI is only ignition protected with the cover correctly installed.

INITIAL POWER UP
  1. Power up the NMEA2000 Network, system will flash all outputs for a short time while booting.
  2. Check that the Network Status LED lights up. It may also be flashing if other devices are on the network and transmitting data.
  3. Turn the switch/circuit breaker on supplying power to the input stud (if fitted).
  4. Check the software version on the OI with the CZone Configuration Tool and update if necessary.
  5. Write the configuration file to the network (Refer to the CZone Configuration Tool Instructions for details on how to write a CZone configuration file).
  6. Test all outputs for correctly configured functionality.
  7. Check the circuit status LED’s for each individual circuit. Refer to LED codes to diagnose any faults which need to be rectified.
SYSTEM DIAGRAM EXAMPLES

ORDERING INFORMATION

Part Numbers and Accessories

Part Number Description
80-911-0009-00 CZONE OUTPUT INTERFACE C/W CONN & BOOT
80-911-0010-00 CZONE OUTPUT INTERFACE NO CONN & BOOT
80-911-0041-00 TERM BLOCK OI 6W PLUG 10 16 PITCH
80-911-0034-00 SEAL BOOT for CZONE OI 6W CONN BK SILICON

SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Technical Specifications


Circuit protection| ATC Fuse with Blown Fuse Alarms
NMEA2000 connectivity| 1 x CAN Micro-C port
Output wire range| 0.5 – 6mm (24AWG – 8AWG)
Output channels| 6 x 20A 12/24V
Maximum current| 100A Total Module Current
Dimming| All channels, PWM @100Hz
Power supply| M6 (1/4″) Positive Terminal (9-32V)
Network Supply voltage| 9-16V via NMEA2000
Circuit bypass| Mechanical Fuse Bypass on all Channels
Ingress protection| IPx5 (mounted vertical on bulkhead and flat)
Compliance| CE, ABYC, NMEA, ISO8846/SAEJ1171 Ignition Protected
Power consumption max| 85mA @12V
Power consumption standby| 60mA @12V
Warranty period| 2 years
Operating temperature range| -15C to +55C (-5F to +131F)
Storage temperature range| -40C to +85C (-40F to +185F)
Dimensions W x H x D| 202.5 x 128.5 x 45mm (7.97 x 5.06 x 1.77”)
Weight| 659g

EMC RATINGS
  • IEC EN 60945
  • IEC EN 61000
  • FCC Class B
  • ISO 7637 – 1 (12V Passenger cars and light commercial vehicles with nominal 12 V supply voltage – Electrical transient conduction along supply lines only)
  • ISO 7637 – 2 (24V Commercial vehicles with nominal 24 V supply voltage – Electrical transient conduction along supply lines only)
  • IEC Standards for indirect lighting strikes
DIMENSIONS

Declaration of Conformity

EU declaration of conformity

This declaration of conformity is issued under the sole responsibility of the manufacturer.
The object of the declaration described above is in conformity wrth the relevant Union harmonization legislation:

References to the relevant harmonized standards used or references to the other technical specifications in relation to which conformity is declared:

Auckland New Zealand

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals