SCARLETT comfort SC-AH986E10 Portable Cheap Air Humidifier Instruction Manual

June 4, 2024
SCARLETT comfort

SCARLETT comfort SC-AH986E10 Portable Cheap Air Humidifier

DESCRIPTION

  1. Water tank
  2. Mist nozzle
  3. Water tank cap
  4. Water inlet
  5. Water tank base
  6. Cabel with plug
  7. ON/OFF button, mist output lever setting (1/2/3)
  8. Timer setting button
  9. Display
  10. Essential oil cup
  11. Membrane
  12. Float

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS

  • Please read this instruction manual carefully before use and keep it in a safe place for future reference.
  • Before the first connection of the appliance check that the voltage indicated on the rating label corresponds to the mains voltage in your home.
  • For home use only. Do not use it for industrial purposes. Do not use the appliance for any other purposes than described in this instruction manual.
  • Do not use outdoors.
  • Always unplug the appliance from the power supply before cleaning and when not in use.
  • To prevent the risk of electric shock and fire, do not immerse the appliance in water or in any other liquids. If it was happened DO NOT TOUCH the appliance, unplug it
  • immediately, and check in the service center.
  • Do not take this product into a bathroom or use it near water.
  • The appliance is not intended for use for physical, sensory, or mental disabled person (including children) or for person with lack of life experience or knowledge, if only they are under supervision or have been instructed about the use of the unit by responsible person.
  • Children must be under control in order not to be allowed to play with the appliance.
  • Do not use other attachments than those supplied.
  • In case of the power cord is damaged, its replacement should be done by the manufacture or service department or the other high-skill person to avoid any danger.
  • Do not attempt to repair, adjust or replace parts in the appliance. Check and repair the malfunctioning appliance in the nearest service center only.
  • Keep the cord away from sharp edges and hot surfaces.
  • Do not pull, twist, or wrap the power cord around appliance.
  • Do not pour the rest water from the gullet when humidifier connected to power supply.
  • When wash humidifier, avoid leaking the water into the inner parts of humidifier otherwise the spare part will be humid and cause problem.
  • When switch on the appliance, do not touch the energy-exchanger.
  • Operate the appliance only with water in the tank. Do not add water over 40 °С into the water tank, or use it for cleaning, to avoid possible deformation or discoloring.
  • Take the humidifier under bottom and support water tank when handle.
  • Do not add water through the mist outlet.
  • Do not add water directly to the water channel on the base.
  • Do not add metals or chemicals into the water tank and the water channel on the base.
  • Avoid water freezing in the humidifier.
  • Do not lift the water tank while the humidifier is working.
  • Do not pour water from the water channel when humidifier connected to power supply. Otherwise the energy exchanger will immediately break.
  • Do not place humidifier close to the ventilating hole and keep away from the furniture and other electrical appliances.
  • If the unit was got from the environment with temperature < 0 ºC, keep it under the room conditions at least 2 hours.
  • ATTENTION: unplug the device from the socket before filling or cleaning.
  • NOTE. During operation it is acceptable that white bloom occurs on the nearby objects which is caused by high-salinity water being used, in this case we it is recommended to fulter the water before pouring it to water tank of the device.
  • The manufacturer reserves the right to introduce minor changes into the product design without prior notice, unless such changes influence significantly the product safety, performance, and functions.
  • Manufacturing date is indicated on the unit and/or on packing as well as in accompanying documents in the following format XX.XXXX where first two figures XX is the month of production, and following four figures XXXX is the year of production.

OPERATION

  • This appliance is used for indoors air humidifying.
  • Place the device on an even dry surface.
  • ATTENTION: Before pouring water inside, unplug the device
  • Remove the reservoir and unscrew the cover, pour in clean water and tightly screw the cover fixing device.
  • ATTENTION: This appliance allows tap water usage. Purified water is still more preferable for usage, especially if tap water is too hard. If tap water is too hard, fill in only distilled or demineralized water.
  • Water tank capacity is 2.3L
  • Wipe the surface of water tank with a dry cloth.
  • Place the water tank onto the base
  • Insert the plug into the socket and switch on the appliance using the on/off dial. Switching on
  • To turn the unit on press left button ON for 1 second Timer settings
  • To chose working time of the unit (from 1 hour to 12hours ), press timer setting button on the right of the unit.The display shows which of the working time you choose.

Mist Output setting

  • You can control the mist output by repeatedly pressing LEFT button. The display shows which of the three levels (1/2/3)you have selected.

Aroma function / Essential oil

  • Put no more than 2-3 drops of essential oil into the essential oil cup before placing water tank onto the base and turning the unit on.
  • Turn on the unit as indicated above.
  • And the scented will become out with the wind after turn on the machine
  • Water level indication
  • When the water level it too low, the unit will automacially turn off and water level indicator will turn red. This means that filling tank with water is needed.

CLEAN AND CARE

  • Do not forget to unplug the appliance from the power supply before cleaning.
  • WASH WATER TANK (EVERY TWO OR THREE WEEKS)
  • ake off the water tank and turn it up.
  • Unscrew the cover.
  • Wipe with a soft cloth and rinse water valve.
  • Wash water tank with warm water (<40 ºC)
  • CLEAN THE WATER CHANNEL AND THE ENERGY EXCHANGER (ONCE A WEEK).
  • If there is scale in the gullet, clean it with soapy water then rinse with water.
  • If there is any stain on the energy exchange, wipe them off with the soft cloth. Then rinse the appliance with clean water. IMPORTANT: Use only a soft cloth to clean the energy exchanger. Never touch it with sharp or hard objects. WASH THE EXTERNAL SURFACE OF HUMIDIFIER
  • First rub the scale and then wash with soft cloth and warm water (<40 ºC).
  • Wash the head of the sprayer with water directly.
  • IMPORTANT: Do not use chemicals, organic solvents or aggressive liquids and abrasives.SCALE REMOVAL
  • Hard scale is not allowed to be removed from the unit surfaces mechanically.
  • Fill water tank with water solution of vinegar, one liter of water needs 150ml of vinegar. Instead of vinegar soda can be used, one liter of water needs 2 table spoon of baking soda.
  • The nozzle of the unit should face open window, so that water mist is directed outdoors.
  • Switch air humidifier for 30-60min
  • Water with soda or with vinegar will eat the scale away during unit usage, so that after the procedure the scale will be removed from the unit walls.

STORAGE

  • Switch off and unplug the appliance.
  • Complete all requirements of chapter CLEAN AND CARE.
  • Keep assembled appliance in a dry cool place.
  • COMMON PROBLEMS AND SOLUTIONS
PROBLEMS CAUSE SOLUTION
The mist is smelling 1.     The appliance is new

2.     Water is dirty

| 1. Wash the tank and change the water Open the water tank and ventilate it for 12 hours
The Indicator light is on, no mist out and no air coming| The water level is excessive-high| 1.     Switch off the appliance and unplug it

2.     Take the water tank off and unscrew the water inlet lid. Pour off some water and close the lid tightly. Wipe the tank dry with a soft cloth. Place the water tank back on the base

3.     Plug the humidifier in. Turn it on

The mist is poor| The energy-changeable appliance has scale or the water is dirty| Wash the energy-changeable appliance and change the water

DISPOSAL

The symbol on the unit, packing materials, and/or documentation means used electrical and electronic units and the batteries should not be tossed in the garbage with ordinary household garbage. These units should be passed to a special receiving point. For additional information about an actual system of garbage collection address the local authority. Valid utilization will help to save valuable resources and avoid negative work on the public health and environment which happens with incorrect using garbage.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>