ZEVNI A04516 3-Light Gold Transitional Chandelier Instruction Manual

June 8, 2024
ZEVNI

ZEVNI A04516 3-Light Gold Transitional Chandelier

INTRODUCTIONS

WARNING (To reduce the risk of fire, electric shock, or personal injury):

  1. We suggest installation by a licensed electrician.

  2. Please read the instruction carefully and save it as you may need it at a later time.

  3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
    » Go to the main fuse, or circuit breaker, box in your home.
    Place the main power switch in the “OFF” position.
    » Place the wall switch in the “OFF” position.

  4. Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides.
    Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.

  5. Make sure that the ceiling or wall can stand the weight of the lamp before installation.

  6. Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.

  7. Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.

  8. When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.

  9. The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products

IMAGE FOR FINISHED PRODUCT

TOOLS REQUIRED (NOT INCLUDED)

| | | |
---|---|---|---|---
Ladder| Phillips head. flat
blade screwdriver| Electrical tape| Pliers| Wire cutter/Stripper

PARTS TYPE & QTY INCLUDING

(A) Mounting plate assembly (1)
(B) Green ground screw (1)
(E) Canopy (1)
(F) Strain relief (3)
(G) Ball knob (2)
(H) Cord (3)
(I) Socket (3)
(J) Glass cover (3)
(K) Shade holder (3)
(L) Glass shade (3)
(M) Socket ring (3)

**ACCESSORIES & QTY ENCLOSED:

**

(C) Plastic Wire Connector (3)
(D) Mounting screw (2)
(N) Allen wrench (1)

ASSEMBLY & INSTALLATION INSTRUCTIONS

  1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
  2. Turn off power
    Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.

» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position.
3 » Unscrew ball knobs (G) from canopy (E) then gently remove mounting plate assembly (A).

4 » Adjust the length of cords (H) to achieve the desired height of the mounted fixture.
1) Use Allen wrench (N) to unscrew the screw in strain reliefs (F), carefully pull and push cords (H) through canopy (E) and strain reliefs (F) to lengthen or shorten the length of cords (H).
2) Once the desired height of fixture is achieved, carefully tighten the screw till snug.

5 » If needed, shorten the extra length of the fixture wires from cords (H) so that they all are at least 6 inches (152.4 mm) long above canopy (E) within the outlet box.

6 » Carefully pass supply wires through mounting plate assembly (A).
Secure mounting plate assembly (A) to the outlet box with mounting screws (D).

7 » Make wire connections Connect wires as below wires connection shown. REFER TO THE FOLLOWING CHARTS, NEVER CONNECT OTHER WIRES TO GROUND WIRES.

Connect ground wires according to the below chart

Connect wires according to the below chart
Connect Black or Red Supply Wire to: Connect White Supply Wire to:
Black White
* Paralle l cord !round & smooth) Parallel cord (square & ridged)
Clear Brown. Gold or Black without tracer Clear. Brown, Gold or Black with

tracer
Insulated wire lather than green) with copper conductor| Insulated wire (other than green) with silver conductor

  • Note: When parallel wires (SPT I & SPT 11) are used. The neutra l wire is square shaped or r idged and the other wire wil l be round in shape or smooth I see illus .I
    www.ihomeangel.com

Twist wires together with plastic wire connectors (C) until tightly joined, and wrap each connector with approved electrical tape for a more secure connection, then carefully tuck all wires into the outlet box.
8 » Fix canopy (E) to mounting plate assembly (A) and secure with the previously removed ball knobs (G).

Note: canopy (E) should be snug against the ceiling and ball knobs (G).
If not, adjust the threaded length of the preassembled mounting screws on mounting plate assembly (A):

  • First, unscrew the pre-assembled hex nuts.
  • Then, screw the pre-assembled mounting screws in or out of mounting plate (A).
  • When the secure length is achieved, tighten the pre-assembled hex nuts and back to step 8.

9 » 1) Remove socket rings (M) from sockets (I).
2) Carefully place glass covers (J), shade holders (K) and glass shades (L) on sockets (I), then secure them with socket rings (M).
3) Install bulbs (Not included) (Please do not exceed the maximum wattage recommended on the socket.)

10. Check everything is already installed properly, then you could turn on the light. Enjoy!

ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts
CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner (such as mild and non-abrasive soap). Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

www.ihomeangel.com
+1 850 296 2377 Working hours : Mon – Fri 9:00 – 16:00 EST
homecustomercare@outlook.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ZEVNI User Manuals

Related Manuals