INSTALLATION SAFETY INSTRUCTIONS
CAUTION This mount is intended for use only with the maximum weights indicated. Use with equipment heavier than the maximum indicated may result in instability causing possible injury.
Do not attempt to install this product until all instructions and warnings
have been read and properly understood.
Please keep these instructions for future reference.
Please check carefully to make sure there are no missing or defective parts –
defective parts must never be used. B-Tech AV Mounts, its distributors and
dealers are not liable or responsible for damage or injury caused by improper
installation, improper use or failure to observe these safety instructions. In
such cases, all guarantees will expire.
General
B-Tech AV Mounts recommends that a professional AV installer or other suitably
qualified person install this product.
Great care must always be taken during installation as most AV equipment is of
a fragile nature, possibly heavy and easily damaged if dropped.
If you do not fully understand the instructions or are not sure how to install
this product safely, then please consult a professional for advice and/or to
install this product for you. Failure to mount this product correctly may
cause serious injury or death, both during installation and at any time
thereafter.
Do not mount any AV equipment that exceeds the specific weight limit of the
product you are installing.
This weight limit will be clearly stated on each product and its packaging and
will vary from product to product.
Product location
Please pay careful attention to where this product is located. Designed for
indoor use, this mount is suitable for public or home installation. Check load
capacity of the floor prior to installation as some surfaces are not suitable
for installation.
When verifying the stability of the structure, consider the following external
factors: The strength of the floor, exposure to sudden and severe wind and
danger arising from contact with people and / or objects (eg installations in
passageways, emergency exits), if located in a public or frequently populated
area ensure that the product is out of the immediate reach of people. When
drilling holes it is essential to avoid contact with electrical cables and
water or gas pipes contained within.
Use of a good quality live wire detector and hidden object locator is
therefore recommended. Only drill into structures when you are sure it is safe
to do so.
Fixing hardware
It is highly recommended that all fixing screws be used where supplied and
that the purpose of all other fixing hardware is fully understood. In some
cases more AV equipment fixing hardware will be supplied to accommodate
different models of equipment and set up configurations. The installer must be
satisfied that any supplied fixing hardware is suitable for each specific
installation.
If any fixing screws or included hardware are deemed not sufficient for a safe
installation then please consult a professional or your local hardware store.
Hazard limitation
When routing cables take advantage of any built in cable management features
that the product might provide and ensure that all cables are tidy and secure.
Check to see that any moving aspect of the product can do so unhindered by any
cabling.
Some products have moving parts and the potential to cause injury through the
crushing or trapping of fingers or other body parts. Particular attention to
the nature of moving parts is required especially when assembling installing
and adjusting during set up. Immediately after installation double-check that
the work done is safe and secure. Double-check all necessary fixings are
present and are of ample tightness.
It is recommended that periodic inspections of the product and its fixing
points are made as frequently as possible (no more than 6 months apart) to
ensure that safety is maintained.
If in doubt consult a professional AV installer or other suitably qualified
person.
SPECIFICATIONS
- Heavy duty floor base with level adjustment suitable for use on uneven floors
- Compatible with a variety of B-Tech columns (BT8380 / BT8381 / BT8385), poles (BT4116 / BT4118) and rails (BT8390)
- Max load per base: 150kg (330lbs)
- Adjustment: +/- 13.5mm (0.5″) in each corner
PARTS LIST
ITEM | PART NAME | QTY |
---|---|---|
1 | BASE PLATE | 1 |
2 | LEVELLING PLATE | 1 |
3 | M8 NUT | 8 |
4 | CUP WASHER | 8 |
5 | DOME WASHER | 8 |
6 | M6 x 40mm CAP HEAD SCREW | 4 |
7 | M8 x 40mm BUTTON HEAD SCREW | 4 |
8 | 5AF HEX KEY | 1 |
DIMENSIONS
THESE INSTRUCTIONS ARE INTENDED AS A GUIDE ONLY AND B-TECH ACCEPTS NO LIABILITY FOR THE ACCURACY OF THE INFORMATION CONTAINED IN THIS DOCUMENT.
INSTALLATION INSTRUCTIONS
BOLT BASE ONTO FLOOR
-
Pre-drill holes in floor and using suitable ground anchor fixings (not supplied), fix item 1 to the floor.
-
Add items 4 & 5 onto the stems of item 1.
ATTACH COLUMN/POLE/RAIL TO PLATE
-
A. BT8380 COLUMN
-
B. BT8385 COLUMN
-
C. BT8381 COLUMN
-
D. BT4116/BT4118 POLE
-
E. BT8390 RAIL
Note: Holes must be threaded on rail
FIX PLATE & COLUMN ONTO BASE
- Mount item 2 onto item 1.
- Fix items 3, 4 & 5 to item 1.
LEVEL BASE
Using a 13mm spanner, loosen the top nut (item 3) and adjust the bottom nut
(item 3) up or down to level item 2. Once level, fully tighten the top nut.
Note: +/-13.5mm adjustment available in each corner.
Customer Support
CONTACT:
info@btechavmounts.com
©2021 B-Tech International Design and Manufacturing Ltd. All rights reserved.
B-Tech AV Mounts is a division of B-Tech International Design and
Manufacturing Ltd.
B-Tech AV Mounts and the B-Tech logo are registered trade marks.
All other brands and product names are trademarks of their respective owners.
Photographs are for illustrative purposes only. E&OE.
AMA-BT8380-AFB-V1-1121-50 MADE IN THE UK
For More Information Visit www.btechavmounts.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>