HACH LICO690 Ultra Low Range Total Chlorine Analyzer

Hach’s Pharmaceutical Quick Guide

  • From process monitoring to quality control to wastewater, Hach® has the right tool for your challenging or routine applications. The comprehensive selection of Hach chemistries, spectrophotometers, electrochemistry meters and probes, and benchtop analyzers provides the broadest range of analyses in the industry.

Lab Instruments and Buffer Standard Solutions

TL23 Turbidimeter

Turbidity measurement has never been easier. The TL23 Turbidimeter is the standard for
turbidity measurement around the world. With tungsten or LED light sources and proven optics, no other instruments deliver more reliable, accurate, and stable measurements. 11ml vial is an application tailored to pharmaceutical customers’ low sample volume request. We also offer IQ/OQ and full service for maintenance.

LICO690

  • Hach has been offering instrumental color measurements of liquids to European Pharmacopeia for over 25 years. Our LICO690 meets all requirements in relation to data integrity in the GxP environment. From January 2021, in addition to the visual color matching method for liquids, new instrumental method has been implemented in chapter 2.2.2 which is tailored towards LICO690. Sample volume starting at 0,8ml, no other supplier can offer smaller volumes. Well equipped with IQ/OQ documentation, certified standards for system controlling, disposable vials, LICO690 is the easiest instrument you have to perform color measurement.

Certified Buffer Standard Solution

Certified standards with full and internationally recognized traceability

  • Hach’s pH buffer standard solution, IUPAC, with certificate of conformity* and traceability; Indication of the exact pH buffer value with associated extended uncertainty (k = 2). Traceable to the IUPAC/NIST pH scale. Guaranteed durability thanks to premium aluminium packaging. Colorless pH buffer solution. Full pH coverage from 1.679-12.45 (k=2) at 25 °C.

Highlights

  • Approved calibration laboratory
  • Fully traceable standards
  • Absolutely reliable packaging
  • GLP (Good Laboratory Practice) from the beginning and every day
  • Ensured traceability

Continuously Monitoring Instruments

Orbis here C1100 Ozone Sensors

  • Hach’s Ozone sensor provides a real zero & a traceable calibration certificate and guarantees the capability of measurement below 1 ppb. Together with our 410/510 controllers, you will have a complete solution for Ozone measurement in your continuous ozonation system.
  • The Orbisphere C1100 has the lowest drift and requests less than 2 instances of maintenance/calibration per year. The instrument provides drift-free and accurate measurements due to true zero reading. The unique platinum guard ring technology prevents false signals arising from the electrolyte.
  • The C1100 ozone sensor has a unique air calibration feature that offers operators a quick and easy method to calibrate without requiring an external standard. Air calibration provides an accuracy of ±5 % (achieving better than ±1 % against an ozone standard of known concentration).
  • The Orbisphere C1100 is the only sensor that provides such certified high accuracy!

HACH-LICO690-Ultra-Low-Range-Total-Chlorine-
Analyzer-04

Ultra Low Range CL17sc

  • Total chlorine confidence. From the global leader in chlorine analysis Meet your unique water cycle needs with the new Ultra Low Range CL17sc online total chlorine analyzer from Hach. Whether treating utility water, product water, or wastewater discharge, you’ll have the direct chlorine measurements you need to optimize your process. You’ll be able to protect valuable assets and report to regulatory agencies with confidence.
  • Monitor and Optimize your Dichlorination process
  • Depend on direct measurements
  • Protect your assets
  • Connect with Claros

Spectrophotometric Measurements

Parameter| Platform| ISO Method|

**Range***

Total and Kjeldahl Nitrogen| DR-Series Spectrophotometer| 10242|

0-16 mg/L N

Nitrite| DR-Series Spectrophotometer| 10207|

0.015-6 mg/L NO2-N

---|---|---|---

**** Phosphate

| DR-Series Spectrophotometer| 10210|

0.15-60 mg/L PO4

---|---|---|---
Chlorine| DR-Series Spectrophotometer| 8021/10069|

0.02-10.0 mg/L Cl2

---|---|---|---
Chemical Oxygen|

DR-Series

| 10211/8000/| 1-15000 mg/L COD
---|---|---|---
Demand| Spectrophotometer|

10212

Silica| DR-Series Spectrophotometer| 8282/8186/8185|

3-100000 µg/L SiO2

---|---|---|---
Copper| DR-Series Spectrophotometer| 8143/8506|

1-5000 µg/L Cu

---|---|---|---
Hydrazine| DR-Series Spectrophotometer| 8141|

4-600 µg/L N2H4

---|---|---|---

  • Ranges reflect multiple chemistries. See Water Analysis Handbook for details.

Analyzers

Parameter| Platform| Method|

Range

pH

| AT1000| Potentiometric|

0-14 pH

Conductivity| AT1000| Potentiometric|

0.01-200000 µS/cm

---|---|---|---
Moisture (Karl Fischer)| AT1000| Volumetric Titration|

0-100 % H2O

---|---|---|---

Turbidity

| TL23 Nephelometer| Nephelometric|

0.01-10000 NTU

---|---|---|---
Electrochemical Measurements

Parameter

| Platform| Electrode|

Range

pH| HQd-Series Meter| PHC201|

0-14 pH

BOD| HQd-Series Meter| LBOD101|

0.1-20.0 mg/L O2

---|---|---|---
ORP| HQd-Series Meter| MTC101 ORP|

±1200 mV

---|---|---|---
Sodium| HQd-Series Meter| ISENA381|

0.023-23000 mg/L Na

---|---|---|---
Microbiological Measurements

Parameter| Platform| Method|

Range

Yeast and Mold| Paddle Test| DOC316.53.01223|

102-106 CFU

ATP| LuminUltra|

Luminescence

|

4×10-12-1×10-6 M ATP

---|---|---|---

  • Outside United States 970-669-3050 fax: 970-461-3939 email : int@hach.com