smartwares FGA-13410 Gas Detector Instruction Manual

June 8, 2024
smartwares

smartwares FGA-13410 Gas Detector Instruction Manual
smartwares FGA-13410 Gas Detector

GENERAL INFORMATION

Thank you for purchasing this Smartwares combustible gas detector! Please read these instructions carefully before using the detector. Retain this information in a safe and easily accessible place for future use and maintenance. If you have any questions or if you are looking for additional information about your gas detector, please visit our website www.smartwares.eu.

Make/model number: FGA-13410

Description:

  • The FGA-13410 household standalone combustible gas detector adopts high quality gas sensor; It is made with high performance MCU and advanced electronic elements as well as sophisticated technologies; Its software and hardware technologies enable it to monitor sensor failure simultaneously when detecting gas leak concentration, which, at the same time, brings a high degree of safety and reliability.
  • This detector is suitable for installing in residential houses with potential gas leakage, it can consecutively monitor indoor combustible gas concentration, when the gas concentration reaches its alarming value, it will send out a sound and light alarm. It will help you to take immediate action to prevent fire, blast and injury accidents from happening.
  • Standard implemented: EN 50194-1:2009

IMPORTANT:

  • Warning: The device is not intended to detect smoke or fire.
  • Caution: The device may not be painted or covered because this may cause loss of functionality.
  • Warning: The device must be replaced no later than 5 years after the installation date or when this is indicated by the Service Life indicator.

Double-insulated Appliances

Icon
In a double-insulated appliance, two insulation systems are provided instead of an earth wire. No earthing means is provided on a double-insulated appliance, nor should a means for earthing be added to the appliance. Servicing a double-insulated appliance requires extreme care and knowledge of the system, and should only be done by qualified service personnel. The replacement parts for a doubleinsulated appliance must be identical to the parts they replace. A double-insulated appliance is labelled with the words ‘CLASS II’ or ‘DOUBLE INSULATED”. It can also be identified with the double insulation symbol.

This product complies with conformity requirements of the applicable European regulations or directives.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local Authority or local store for recycling advice.

PARTS DESCRIPTION

  1. Status LED indicator
  2. Service Life LED indicator
  3. Test button
  4. Alarm speaker
  5. Gas detection vents
  6. Power supply cable
  7. Extra cable input (not for use with this model)
  8. Mounting plate

INSTALLING THE GAS DETECTOR

Before mounting your Gas detector, please stick the rating label in your own language (if included) to the detector.
This detector is suitable for indoor environment only, please install it in places with potential gas leakage. It should be installed horizontally 1m~4m from the gas appliance and vertically >0.3m from the ceiling.

  • The device should only be installed by a competent person.

Avoid areas as below:

  • Areas of ventilation inlet/outlet, exhaust fan, doors/windows with strong air flow.
  • Areas with moisture and water drops.
  • Areas right above heat source or water steam.
  • Areas above gas appliances.
  • Areas easy to be polluted.
  • Areas covered by obstacles.
  • If the room is to be painted or refurbished, please install the detector after the refurbishment or painting work is done.

Wall mount installation

  • Choose a place on the wall suitable for installing the detector.
  • Use the screws supplied to fix the installation baseplate onto the wall, with the attachment pins facing upwards.
  • Power on the detector and check to ensure it works normally.
  • Attach the detector onto the baseplate by aligning the attachment pins with the holes on the device and sliding it downwards until it clicks.

USE

  • Connect the detector to the power source, the LED ring indicator will flash green, and the detector will enter a 3-minute preheating status.
    During preheating, the detector cannot detect gas leakage, after preheating the detector will enter normal detection mode and the LED ring indicator will remain illuminated.

  • When the gas concentration value in the air reaches the set alarming point, the detector will enter alarming mode, the LED ring indicator will flash red and a beeping alarm will be sounded.

  • A gas leakage can be detected by the device or by scent. Follow the steps below if a gas leak is detected by scent or an by an alarm.

What to do in the event of an alarm/ gas detection.
In case of an alarm/gas detection please shut off the gas supply, open the windows, evacuate the premises immediately and do not turn on any electrical appliances (including cell phones). If necessary, please ask for gas experts to eliminate the gas leakage. Only enter the building again when the problem has been solved and the gas has disappeared.

  • In the alarm state, when the gas concentration value is at a safe level, the detector will disarm the alarm automatically.

Service life indicator
If the Service LED Indicator is illuminated yellow and a constant beeping is heard, it means the detector is defected and cannot detect correctly, if this happens please visit our Customer Service at www.smartwares.eu for more information.

  • Testing your detector

It is important that the functionality of your detector is tested every 6 months. To test the detector, short-press the test button once, the LED ring indicator will flash red and 4 beeping alarms will be sounded. If the detector does not alarm normally please visit our Customer Service at www.smartwares.eu for more information.

LED Indicator Status

Mode LED Ring indicator Service Life indicator Buzzer
Pre-heating mode Flashes green
Normal mode Constantly green Constantly green
Testing state Flashes red 4 beeps
Failure mode Constantly yellow Constant beeping
Alarming mode Flashes red Constant cycle of 4 beeps
Service life due Flashes yellow Constant cycle of 3 beeps

MAINTAINING YOUR GAS ALARM

To maintain your device in proper working order, it is recommended that you:

  • Test your alarm at least once every 6 months.
  • Clean the device regularly to prevent dust build up. This can be done using a soft damp cloth once per month. Clean gently around the front grilled section and sides.
  • Never use cleaning solutions on your alarm. Simply wipe with a damp cloth.
  • Do not paint the alarm.
  • Do not block or cover the alarm’s ventholes with paste adhesive or other materials.

ATTENTION

When scouring or stripping a wooden floor, painting, wallpapering or using adhesive or aerosol, you should remove the device and keep it in a safe place to prevent damaging the sensor. High concentrations of the following substances can damage the sensor, which often results in a false alarm: methane, propane, isopropyl butane, ethylene, ethanol, alcohol, isopropyl alcohol, benzene, toluene, ethyl acetate, hydrogen, hydrogen sulphate and sulphur dioxide. Also, aerosol sprays, alcoholic products, paint, solvents, adhesive, hair spray, aftershave, perfume and certain cleaning agents can cause damage.

TECHNICAL DATA

Operating Voltage AC 100V~220V/50Hz~60Hz
Power Consumption ≤4W
Operating Environment Temp: 0℃~55℃Relative Humidity: <95% (non-

condensation)Ambient Pressure: 86kPa~106kPa
Storage Temperature| -25℃~55℃
Response Time| ≤30s
Sampling Method| Free diffusion
Applicable for| Methane (CH4) + Propane (C3H8) + Butane (C4H10)
Sensor Type| Semi-conductor
Sensor Life| 5 years (typical value)
Alarming Value| 10%LEL ±3%LEL
Alarming Mode| Sound + Light
Alarming sound Level| ≥85dB (1 meter ahead)
Installation| Wall-mounted
Standard| EN 50194-1:2009

Risk of electrical shock, do not tamper with the device.

TROUBLESHOOTING

Failure Possible reason Measure(s)
Green power source indicator not on Power source cable not connected
correctly Check and connect the power source cable correctly
Power source indicator damaged or circuit failu Visit our customer service at

www.smartwares.eu for more information
No sound and light alarm during self-check| Circuit failure| Visit our customer service at www.smartwares.eu for more information
No response to detected gas| Still under pre-heating| Wait till pre-heating ends
Circuit failure| Visit our customer service at www.smartwares.eu for more information
Continuous alarming after turning on the device and pre-heating time has elapse| The environment is polluted with a significant amount of cigarette smoke, alcohol or volatile organic compounds like petrol, perfume, isoamyl acetate, or paint| Move to clean air spaces and try it again
Circuit failure| Power on and wait for at least 2 hours
Too long storage time P| Power on and wait for at least 2 hours

INTENDED USE: FIRE SAFETY

ESSENTIAL CHARACTERISTICS: PASSED

  • Nominal activation conditions/ Sensitivity, Response delay (response time) and Performance under fire condition
  • Operational reliability
  • Tolerance to supply voltage
  • Durability of operational reliability and response delay, temperature resistance
  • Durability of operational reliability, vibration resistance
  • Durability of operational reliability, humidity resistance
  • Durability of operational reliability, corrosion resistance
  • Durability of operational reliability, electrical stability

Distributed by:

Jules Verneweg 87 5015 BH Tilburg
The Netherlands
www.smartwares.eu

Conform with
EN50194-1:2009

DECLARATION OF CONFORMITY- For DoC go to: www.smartwares.eu/doc and follow the instructions.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

smartwares User Manuals

Related Manuals